User Guide 

Security System 

 

DS7400XiV4-EXP 

Содержание DS7400XiV4-EXP

Страница 1: ...EN User Guide Security System DS7400XiV4 EXP ...

Страница 2: ... for Temporary PINs 24 9 0 Error Displays 25 9 1 System Faults 26 10 0 Testing Your System 27 10 1 Zone Test 27 10 2 Battery Tests 28 10 3 Communicator Test 28 10 4 Fire Walk Test 29 10 5 Event History Readback 30 11 0 The Master Keypad Text Keypad Only 31 11 1 General Information 31 11 2 Master Keypad Displays 31 11 3 Single Partition Mode 32 11 4 Arming from the Master Keypad 32 11 5 Disarming f...

Страница 3: ... station In the unlikely event that the central station cannot receive the report your phone could be unavailable for up to 20 minutes while the system tries to communicate with the station 0 If your system is not monitored by an alarm monitoring service you must understand alarms sound only at your location no signals are sent when an alarm occurs duress and other silent alarms are disabled emerg...

Страница 4: ...ng commands only for the area in which the user has authority If the user PIN has authority in more than one area the user can arm or disarm those areas by entering the commands from any keypad Only users with access to all areas attached to a common zone can arm that common zone If the user PIN has authority in more than one area the user can arm or disarm the first area only by entering the PIN ...

Страница 5: ...t Refer to Section 9 0 Error Displays Normal Operation The control panel is running on AC power with no problems Fire red There are no fire alarms A fire zone is in alarm A fire trouble condition exists These status LEDs are present only on the LED Keypad Table 2 Status LEDs LED Off Flashing On Perimeter yellow Control panel is disarmed or is not perimeter armed This LED does not flash The perimet...

Страница 6: ...everal years but battery life can vary depending on the amount of use they receive If you notice the range of the RF device is decreasing or if the LED is not working it might be time to replace your battery Refer to the documentation that came with your RF device for recommended replacement batteries and instructions for battery replacement Your RF device does not indicate if the alarm system is ...

Страница 7: ... keypad Ready to Arm must be displayed If the green LED is not on or the keypad displays Not Ready you must use other methods to arm the system refer to Section 6 2 2 Force Arming on page 13 or Section 6 2 3 Zone Bypass on page 14 Table 3 Normal Arming Equipment Command Sequence What Happens What To Do Text Keypad LED Keypad PIN On The red Armed LED flashes Armed is displayed Exit Now is displayed...

Страница 8: ...Table 4 Perimeter Instant Arming Equipment Command Sequence What Happens What To Do Text Keypad LED Keypad PIN No Entry Perimeter Only The red Armed LED flashes Perimeter Inst is displayed Exit Now is displayed during exit delay The green Status LED lights steady A single beep sounds The red Armed LED lights steady when the exit delay period ends The yellow Perimeter LED lights steady Only exterio...

Страница 9: ...Arming Equipment Command Sequence What Happens What To Do Text Keypad LED Keypad PIN Perimeter Only The red Armed LED flashes Perimeter On is displayed Exit Now is displayed during exit delay The green Status LED lights steady A single beep sounds The red Armed LED lights steady when the exit delay period ends The yellow Perimeter LED lights steady Only exterior protection zones are armed Move fre...

Страница 10: ...ming on page 13 or Section 6 2 3 Zone Bypass on page 14 Table 6 Custom Arming Equipment Command Sequence What Happens What To Do Text Keypad LED Keypad PIN 4 The red Armed LED flashes On Partial is displayed Exit Now is displayed during the exit delay period The green Status LED lights steady A single beep sounds The red Armed LED lights steady when the exit delay period ends The zones that were p...

Страница 11: ... Section 6 2 3 Zone Bypass on page 14 Table 7 Maximum Security Arming Equipment Command Sequence What Happens What To Do Text Keypad LED Keypad PIN No Entry On The red Armed LED flashes Armed Instant is displayed Exit Now is displayed during the exit delay period A single beep sounds The red Armed LED lights steady when the exit delay period ends All zones are armed Exit during the exit delay peri...

Страница 12: ...PIN Off The red Armed LED turns off All sounders are silenced All zones are disarmed A single beep sounds If a fire alarm was sounding Sounder Silenced is displayed until the system is reset Determine why the sounders if any were activated Correct the cause If a fire alarm was sounding correct the cause and press System Reset or 4 7 to reset the system RF3341 Keypad PIN The LED flashes indicating ...

Страница 13: ...341 keypad You can also force arm an area using a master keypad in Single Partition Mode Force Arming during an AC power failure Regular arming of the control panel is not permitted during an AC power failure The requirement to force arm serves as a warning that the control panel is operating under backup battery Bypassing or force arming removes some of your building s protection because it exclu...

Страница 14: ...equence What Happens What To Do Bypass Faulted Zones PIN Bypass XXX XXX XXX The green Status LED flashes if no other zones are faulted If desired arm the control panel after bypassing Read Bypassed Zones PIN Bypass Bypass is displayed on a text keypad followed by the zone number s of any bypassed zones All zones normally armed by the arming command sequence are armed except for faulted zones If de...

Страница 15: ...ur clock format and press the key If you make a mistake press the key twice to move back to your last entry Time examples 12 midnight 2400 12 noon 1200 12 01 am 0001 12 01 pm 1201 1 00 am 0100 1 00 pm 1300 Disabled 0000 6 2 5 Delaying Automatic Arming When automatic arming is set a pre arming period begins 15 minutes before the system arms automatically to inform occupants that the system is about...

Страница 16: ... for each day in 24 hour clock format Programming starts with Sunday The keypad displays Sunday nn nn Enter the time in 24 hour clock format and press the key If you make a mistake press the key twice to move back to your last entry Time examples 12 midnight 2400 12 noon 1200 12 01 am 0001 12 01 pm 1201 1 00 am 0100 1 00 pm 1300 Disabled 0000 6 2 7 Delayed Arming Delayed arming causes the system t...

Страница 17: ...eypad PIN 7 Chime Mode Off displays for 5 seconds The LED flashes indicating a signal was sent to your security system Chime Mode is turned off Text Keypad only LED Keypad only 6 2 9 Access Control Your system might use a keypad key sequence to activate other electrical devices Access control is not available from an RF wireless keypad or from the keyfobs Refer to Access Code on page 24 This featu...

Страница 18: ...mmand sequence Master Code 0 2 causes the text keypad to display the date 6 2 11 Setting the System Clock Because you can only set the time on the system clock in Master Programming Mode you cannot program the system clock from an RF wireless keypad Record your entries so they are available before you enter Master Programming Mode Enter the parameters promptly If a delay of 15 seconds or more occu...

Страница 19: ... alarm If the alarm was not investigated do not enter the building unless accompanied by the appropriate Emergency Services personnel 7 5 Fire Alarms Fire alarms are silenced by entering a PIN with disarm privileges the Off key The fire alarm system is not reset until smoke detectors alarms are cleared by using the System Reset command The fire alarm system is not functional until this procedure h...

Страница 20: ...s and hallways might be blocked during a fire the plan must provide exits from bedroom windows Make copies of the plan and practice it with all family members Pre arrange a meeting place outside and away from the residence Once out of the building all occupants should immediately go to the pre selected location to be accounted for Figure 3 Escape Plan 1 2 1 5 3 4 1 Bedroom 2 Hall 3 Dining Room 4 B...

Страница 21: ... Detector Install smoke detectors between sleeping areas and family living areas 7 9 Emergency Keypad Alarms Silencing Alarms The Emergency Alarm Keys and can generate Fire Special Emergency and Panic Alarms if programmed by the installer Ask your installing company to explain the function of these keys To use an Emergency Key you must press the button for two seconds to generate an alarm Use the ...

Страница 22: ...tem so you do not inadvertently enter a Duress PIN You can enter the Duress PIN at any keypad but you cannot disarm the system under duress from a keyfob In a duress situation avoid using a keyfob to disarm the system since this prevents you from notifying the monitoring service of your need for assistance Table 20 Disarming Your System under Duress Equipment Command Sequence What Happens What To ...

Страница 23: ... 2 Removing a PIN To disable remove a PIN 1 Enter a Master code and press 0 0 2 Enter the user number of the PIN to be cancelled and press You cannot disable User Number 001 using this method 8 3 Changing a PIN Since you can only change PINs in Master Programming Mode they are not programmable from an RF wireless keypad Change PINs at a text keypad because no visual clues are provided by an LED ke...

Страница 24: ... the system Refer to Section 7 10 Turning OFF Disarming Your System under Duress on page 22 6 Access Code When a PIN with an access code is entered any output programmed for access output for example door strikes pulse on for 10 seconds works when the system is armed or disarmed 8 5 Changing the Expiration Date for Temporary PINs Since you can only change the expiration date for temporary PINs in ...

Страница 25: ...t to perform a battery test LED 3 on Communicator Err The control panel failed to communicate with the central station LED 4 on System Fault Internal error in the control circuitry or optional circuitry Refer to Section 9 1 System Faults LED 5 on Keypad Fault One of the keypads is not responding to the control panel LED 6 on Keypad Tamper One of the keypad housings was opened LED 7 on Multiplex Bu...

Страница 26: ... line module aux relay fault System Fault 14 Oct Relay Fault loss of communication to octal relay module System Fault 20 Reserved for older control panels System Fault 50 AR IB Queue Full modem buffer full System Fault 51 AR Host Down network data switch down System Fault 52 AR Unreg Modem modem not registered System Fault 53 AR Power Fail power source below defined threshold System Fault 54 AR Ne...

Страница 27: ...one test is complete a test restoral report is sent to the central station If you perform this test from a Master Keypad the keypad must be in Single Partition Mode Zone tests are not available from RF wireless keypads Test the system weekly Table 25 Zone Test Type of Test Command Sequence What Happens What To Do Zone Test PIN 8 1 Test Zone is displayed followed by the numbers of the zones that we...

Страница 28: ...ge 25 If the sounder fails to operate or if the battery fails contact your installing company Battery Test PIN System Reset The control panel performs a battery test The control panel reports a Low Battery or a Low Battery Restoral is necessary Contact your installing company if a low or missing battery is reported 10 3 Communicator Test This test is available only if your system sends alarms and ...

Страница 29: ...tended to 20 minutes every time you test another zone When you test a fire zone any output programmed to follow that zone is activated for 5 seconds Table 28 Fire Walk Test Type of Test Command Sequence What Happens What To Do Fire Walk Test PIN 9 1 Fire Test is displayed followed by the number of any zones that are untested The LEDs of any untested zones flash Fire Testing is displayed followed b...

Страница 30: ...Readback Note To read the System Error Displays follow the instructions in Section 9 0 Error Displays Scroll through the events using the 9 6 and keys Exit from Event History using PIN Text keypad only LED keypad only Scrolling through the History Events Text Keypad Only Press to scroll back through the history line by line Press 9 to scroll in reverse chronological order by event Press 6 to scrol...

Страница 31: ...eypads The Master Keypad display scrolls the status of each area followed by the area number For example if all areas are armed the Master Keypad scrolls through the following displays Armed area 1 Armed area 2 Armed area 3 Armed area 4 Armed area 5 Armed area 6 Armed area 7 Armed area 8 If only areas 1 2 3 4 6 and 8 are armed the Master Keypad scrolls through the following displays Armed area 1 A...

Страница 32: ...g the key twice The next area to which you have access is displayed Ready to Arm Office Enter the desired command sequence for this area Exit Single Partition Mode by holding the key for 2 seconds 11 4 Arming from the Master Keypad Table 31 Arming from the Master Keypad Type of Arming Desired Command Sequence Arming all the areas to which you have access PIN and any Arming Command Sequence This ar...

Страница 33: ...ch you have access 1 PIN You are in Single Partition Mode The first area to which you have access is displayed Armed Cafeteria 2 Press Off if you want to disarm this area If not go to the next step 3 Press to open the next area to which you have access The next area to which you have access is displayed Armed Office 4 Press Off if you want to disarm this area If not go to the next step After disar...

Страница 34: ... Strike A mechanism connected to the control panel to limit access through a door to those users with an Access Control PIN Entry Delay An Entry Delay is a predetermined amount of time that allows entry into an armed area Exit Delay An Exit Delay is a predetermined amount of time that allows you to exit an area just after you arm it Faulted Zone A Faulted Zone is a zone that is not ready to arm fo...

Страница 35: ... Installing Company Phone No Use the chart below to list your protected areas For example if Zone 1 is your front door the installer should write Front Door on the line provided for Zone 1 Zone Protected Area Zone Protected Area Zone Protected Area Zone Protected Area 1 33 65 97 2 34 66 98 3 35 67 99 4 36 68 100 5 37 69 101 6 38 70 102 7 39 71 103 8 40 72 104 9 41 73 105 10 42 74 106 11 43 75 107 ...

Страница 36: ...32 162 192 222 133 163 193 223 134 164 194 224 135 165 195 225 136 166 196 226 137 167 197 227 138 168 198 228 139 169 199 229 140 170 200 230 141 171 201 231 142 172 202 232 143 173 203 233 144 174 204 234 145 175 205 235 146 176 206 236 147 177 207 237 148 178 208 238 149 179 209 239 150 180 210 240 151 181 211 241 152 182 212 242 153 183 213 243 154 184 214 244 155 185 215 245 156 186 216 246 1...

Страница 37: ..._________ Force Arming Enter an arming command sequence followed by the Bypass key on text LED keypads or the 9 key for RF3341 keypads The maximum number of zones that can be forced armed is _____ Zone Bypass PIN Bypass followed by the Zone number Quick Arming Your System Normal Arming On Perimeter Arming no entry delay No Entry Perimeter Only Perimeter Arming with entry delay Perimeter Only Maxim...

Страница 38: ...DS7400XiV4 EXP User Guide Notes EN 38 Bosch Security Systems 6 05 4998154961B Notes ...

Страница 39: ...DS7400XiV4 EXP User Guide Notes EN 39 Bosch Security Systems 6 05 4998154961B Notes ...

Страница 40: ... 2005 Bosch Security Systems 4998154961B Bosch Security Systems www boschsecuritysystems com ...