Page 60 P/N: F01U035325-01
Copyright © 2007 Bosch Security Systems, Inc.
DS7400Xi (4+) Reference Guide
10.36 Octal Relay Module Output Programming
10.36.1 Follow Action: Program Addresses (2740-2771)
To program an Octal Relay Module for Follow Action, follow the steps below.
1. Select Octal Relay to program.
2. Program Data Digit 1 of Program Address A as 1 for Follow Action.
3. Program Data Digit 2 of Program Address A for the desired function.
4. Program Data Digit 1 and 2 of Program Address B for the desired function.
Once both Address A and Address B have been programmed, proceed to program the next Octal Relay.
The Octal Relay Module is the DS7488. See section 1.18 and 6.4 for further details.
NOTE:
If a DS9484 is used, it replaces the DS7488 and takes up outputs 1-4 of the Octal Relay Module. Outputs 5-8 of the Octal Relay
Module are unavailable. If two DS9484 power supplies are used, one replaces Octal Relay Module 1 and the other replaces
Octal Relay Module 2.
For Octal Relay Partition Assignment, see section 10.36.5.
0
1
2
SELECT OPTION DD 2
3
Follows
Disabled
Burglar Alarm
Fire Alarm
Octal
Relay
#
DS7488-1
Address
A
DS7488-1
Address
B
1
2
3
4
5
6
7
8
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
9
10
11
12
13
14
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
15
16
DD
0 0
Latch ON after Zone Alarm**
ON during Entry Pre-Alert
ON for 10 sec. after pressing [System Reset]
ON for Any Armed state
Ground Start
System Status (Ready to Arm)
Zone Alarm
Zone Alarm delayed by 20 seconds
Keypad Sounder Output
Access Output (10 sec. pulse)
0 1
0 2
0 3
0 4
0 5
0 6
0 7
0 8
0 9
SELECT OPTION DD 1 & 2
Panic/Duress Output***
0*1
ON when System is Partial
0*2
0*0
0*3
ON when System is Fully Armed
1
2
Data Digit
Program Address B
1
2
Data Digit
1
Program Address A
Future Selection
** = This includes invisible zones. See glossary for further details.
*** = See section 6.4 for description of this option.