DS12R
|
Installation and Operation Guide | Wireless Maintenance
18
Bosch Security Systems, Inc. | 5/08 | F01U081956-01
4.0
Wireless Maintenance
4.1
Wireless Device Test Mode
Disarm the system before using Test
Mode. The DS12R ignores all zone input
while in Test Mode. All keys function
normally.
Use Test Mode to check the signal strength of the
wireless receiver. The DS12R LEDs indicate if the
location of the receiver is acceptable, marginal, or out
of range.
To enter Test Mode:
1.
Enter the Master Code.
2.
Press and hold [#] for three seconds. Zone LEDs
7–12 flash quickly to indicate that you entered Test
Mode.
Zone LEDs 1, 2, 3, 4, 5, and 6 indicate signal
strength
Refer to
Table 6
to interpret LED indications
.
Table 6: Wireless Signal Strength
RF
Receiver
LED Signal
Strength
1
Poor, relocate RF
receiver
1 and 2
Marginal, relocate RF
receiver
1
1, 2, and 3
Good
4
Poor, relocate RF
receiver
4 and 5
Marginal, relocate RF
receiver
2
4, 5, and 6
Good
3.
To exit from Test Mode:
•
Press and hold [#] for 3 sec, or
•
Wait 3 min for the DS12R to exit
automatically from Test Mode.
The LEDs return to their previous condition after
Test Mode is finished.
4.2
Low Battery Trouble
The DS12R beeps twice every minute when it receives
a low battery signal from the wireless receiver. The
LED for the zone with the low battery condition flashes
once each second.
If [RESET] is pressed, the DS12R ignores the low
battery condition for up to eight hours. If, after eight
hours, the low battery condition is still present, the
DS12R beeps again.
4.3
Supervisory Trouble
You can program the DS12R to ignore Supervisory
Trouble conditions for 12 or 24 hours. After the
programmed time, the DS12R beeps once each minute.
The corresponding zone LED flashes once each
second. When the supervisory condition clears, the
flashing and beeping stop.
Program Address 56 sets the Supervisory Trouble time.
Refer to
Table 3
beginning on page 11.
5.0
Specifications
Table 7: DS12R Specifications
Dimensions:
17.0 cm x 13.0 cm x 3.2 cm
(6.7 in. X 5.1 in. x 1.3 in.)
Weight:
0.35 kg (12.3 oz)
Operating
Temperature:
-10
0
C to + 50
0
C
(-4
0
F to +122
0
F)
Relative Humidity :
0 to 93% non-condensing
Operating Voltage:
9 VDC to 15 VDC
Zones:
Normally-open (NO) or normally-
closed (NC) zones.
Zone Response
Time:
500 ms
Zone EOL Resistor:
47 k
Ω
Output Relay:
Normally open (NO) or normally
closed (NC). Contacts rated for
3 A at 28 VDC
Solid State Outputs:
Two DC current sink outputs.
250 mA current sink maximum per
output at 0.1 VDC saturation. The
operating voltage must not exceed
15 VDC.
Compatible Wireless
Receivers:
RF3212 and RF3212e
Tamper:
Built-in cover and wall tamper