DS12R
|
Installation and Operation Guide | Programming
16
Bosch Security Systems, Inc. | 5/08 | F01U081956-01
3.5
Programming Wireless Devices
The DS12R supports two RF3212 or RF3212e Wireless
Receivers. Mount the receivers up to 20 m (65.7 ft)
from the DS12R.
The DS12R supports up to 6 key fobs and 24 wireless
devices, including motion detectors, smoke detectors,
and door contacts.
You can assign up to two wireless devices to a zone.
Refer to
Table 5
.
Table 5: Wireless Device Assignments
RF Zone
Program Address
Wireless Device
57
Device 1
1
58
Device 2
59 Device
1
2
60 Device
2
61
Device 1
3
62
Device 2
63 Device
1
4
64 Device
2
65
Device 1
5
66
Device 2
67 Device
1
6
68 Device
2
69
Device 1
7
70
Device 2
71 Device
1
8
72 Device
2
73
Device 1
9
74
Device 2
75 Device
1
10
76 Device
2
77
Device 1
11
78
Device 2
79 Device
1
12
80 Device
2
N/A
81
Key fob 1
N/A
82
Key fob 2
N/A
83
Key fob 3
N/A
84
Key fob 4
N/A
85
Key fob 5
N/A
86
Key fob 6
Each wireless device is labeled with a unique, nine-digit
identification number (ID)
.
Refer to
Figure 13
.
Figure 13: Device Identification Number (ID)
16 77 70 187
16 77 70 187
16 77 70 187
16 7770 18 7
or
To add a wireless device to the system:
1.
Enter Programming Mode.
2.
Select the appropriate program address.
Refer to
Table 5
.
3.
Enter the nine-digit ID for the wireless device.
4.
For key fobs, set Program Address 55 to 1.
This setting enables up to six key fobs.
You cannot assign the Master Code to a
key fob. Assign each key fob to a different
user. All Exit Delay and Entry Delay times
operate as if the DS12R is armed or
disarmed using a standard user code.