background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 

Installation and Operation Guide 

Self-Contained Control 
Panel 

 

DS12R 

Содержание DS12R

Страница 1: ...EN Installation and Operation Guide Self Contained Control Panel DS12R ...

Страница 2: ...Installation and Operation Guide Trademarks 2 Bosch Security Systems Inc 5 08 F01U081956 01 Trademarks Microsoft is a registered trademark of Microsoft Corporation in the United States and or other countries ...

Страница 3: ...ogramming 10 3 1 Entering Programming Mode 10 3 2 Changing Programming Values 10 3 3 Exiting Programming Mode 10 3 4 Checking Programmed Data 10 3 5 Programming Wireless Devices 16 3 6 Resetting Default Values 17 3 6 1 Reset the Master Code 17 3 6 2 Reset Programming Default Values 17 3 7 Configuring the Working Mode 17 3 7 1 Configure as a Stand alone System 17 3 7 2 Configure for use in an MTS s...

Страница 4: ... 8 zone input device MT2 8 8 output device MT3 1 Single zone input output device Controller Area Network CAN wiring requirements are as follows CAN Bus Interface Connect the CAN bus to the MTR Communication Receiver with at least 1 5 mm 16 AWG shielded twisted pair wire maximum length 2000 m 6500 ft RS 485 Buses 1 3 Use at least 1 0 mm 20 AWG shielded twisted pair wire for the RS 485 bus maximum l...

Страница 5: ...sch Security Systems Inc 5 08 F01U081956 01 5 Figure 1 MTS System Overview 1 MTSW Security Station Software 2 MTR Communication Receiver 3 CAN Bus 1 4 CAN Bus 2 5 MTGW CAN RS 485 Bus Gateway 6 RS 485 Device DS12R is shown 7 RS 485 Device DS6R2 is shown ...

Страница 6: ...ewdriver to press the release tabs on the bottom of the keypad Refer to Figure 2 Figure 2 Opening the DS12R 1 Release tab 2 Mount the base on the intended surface or electrical box Refer to Figure 3 The three terminal strips provided on the DS12R base slide in and out of their respective holders to facilitate installation Figure 3 Mounting Holes 1 Holes for surface mounting 2 Holes for electrical ...

Страница 7: ...ure 5 DS12R Terminal Strips 1 Terminal Strip 1 TS1 2 Terminal Strip 2 TS2 3 Terminal Strip 3 TS3 Table 2 Terminal Wiring Terminal Strip 1 TS1 Label Description Z1 Zone 1 COM Common earth ground Z2 Zone 2 Z3 Zone 3 COM Common earth ground Z4 Zone 4 Z5 Zone 5 COM Common earth ground Z6 Zone 6 Z7 Zone 7 COM Common earth ground Z8 Zone 8 Terminal Strip 2 TS2 Label Description Power 12 VDC Power common...

Страница 8: ...h between the INS terminal and the zone s COM terminal The Entry Exit Delay zone returns to the programmed delay when the switch is open Refer to Figure 7 Figure 7 Instant Zone Wiring Smoke Detector Wiring The DS12R supports four wire smoke detectors Figure 8 shows a smoke detector connected to an end of line EOL relay module Figure 9 shows an EOL resistor connected to a smoke detector The total c...

Страница 9: ...ut Wiring The DS12R has Form C NO C NC contacts rated for 3 A at 28 VDC Two solid state current sinks can be used for devices with a current draw of up to 250 mA for each device Refer to Figure 11 The operating voltage for attached relays cannot exceed 15 VDC Refer to Program Addresses 44 and 45 in Table 3 on page 13 for output options Figure 11 Output Wiring 1 Device 1 2 Device 2 3 Normally open ...

Страница 10: ...e can be from one digit to nine digits in length depending on the address A beep indicates the input is accepted Refer to Table 3 beginning on page 11 3 Repeat Steps 1 and 2 to program other addresses If you make an incorrect entry before completing the number press to clear the previous entry and then re enter it If you enter the wrong digits and complete the number press and re enter the program...

Страница 11: ...ne 7 Perimeter delay zone 10 Zone 4 Type 1 1 1 Instant 2 Delay 2 3 24 hour 4 Follower 5 Silent zone 6 Perimeter instant zone 7 Perimeter delay zone 11 Zone 5 Type 1 1 1 Instant 2 Delay 2 3 24 hour 4 Follower 5 Silent zone 6 Perimeter instant zone 7 Perimeter delay zone 12 Zone 6 Type 1 1 1 Instant 2 Delay 2 3 24 hour 4 Follower 5 Silent zone 6 Perimeter instant zone 7 Perimeter delay zone 13 Zone ...

Страница 12: ...lowed 27 Zone 9 Bypass 3 2 1 Bypass allowed 2 No bypass allowed 28 Zone 10 Bypass 3 2 1 Bypass allowed 2 No bypass allowed 29 Zone 11 Bypass 3 2 1 Bypass allowed 2 No bypass allowed 30 Zone 12 Bypass 3 2 1 Bypass allowed 2 No bypass allowed 31 Zone 1 Swinger Bypass 2 1 Zone swinger bypass allowed 2 No zone swinger bypass allowed 32 Zone 2 Swinger Bypass 2 1 Zone swinger bypass allowed 2 No zone sw...

Страница 13: ...to six 0 0 Disable 1 Enable 56 RF Supervisory Trouble 1 1 Report supervisory trouble after 12 h 2 Report supervisory trouble after 24 h 57 6 RF Zone 1 Device 1 ID Number 000000000 000000000 Disabled zone is hard wired Allows 000000001 to 999999999 ID numbers 1 This output is normally open but drops to 0 V when the system is armed or an alarm occurs If this output drops to 0 V after an alarm occurs...

Страница 14: ...000 000000000 Disabled zone is hard wired Allows 000000001 to 999999999 ID numbers 69 1 RF Zone 7 Device 1 ID Number 000000000 000000000 Disabled zone is hard wired Allows 000000001 to 999999999 ID numbers 70 1 RF Zone 7 Device 2 ID Number 000000000 000000000 Disabled zone is hard wired Allows 000000001 to 999999999 ID numbers 71 1 RF Zone 8 Device 1 ID Number 000000000 000000000 Disabled zone is ...

Страница 15: ...ng this zone causes an alarm after the Entry or Exit Delay time setting expires 24 hour This zone is always active Faulting this zone always causes an alarm Follower When the system is armed and a Delay zone is not faulted faulting this zone causes an alarm If a Delay zone is faulted an alarm occurs after the delay time Silent Zone When the system is armed faulting a Silent zone causes a Silent al...

Страница 16: ... 70 Device 2 71 Device 1 8 72 Device 2 73 Device 1 9 74 Device 2 75 Device 1 10 76 Device 2 77 Device 1 11 78 Device 2 79 Device 1 12 80 Device 2 N A 81 Key fob 1 N A 82 Key fob 2 N A 83 Key fob 3 N A 84 Key fob 4 N A 85 Key fob 5 N A 86 Key fob 6 Each wireless device is labeled with a unique nine digit identification number ID Refer to Figure 13 Figure 13 Device Identification Number ID 167770187...

Страница 17: ... Values 1 Enter Programming Mode 2 Enter 9 9 Program Address 99 3 Enter 18 for the programming value 1 8 4 Press and hold PROGRAM for 3 sec to exit from Programming Mode The DS12R resets all programming values to the original factory defaults 3 7 Configuring the Working Mode The DS12R can be used as stand alone system or as a component of an MTS system 3 7 1 Configure as a Stand alone System 1 Rem...

Страница 18: ... receives a low battery signal from the wireless receiver The LED for the zone with the low battery condition flashes once each second If RESET is pressed the DS12R ignores the low battery condition for up to eight hours If after eight hours the low battery condition is still present the DS12R beeps again 4 3 Supervisory Trouble You can program the DS12R to ignore Supervisory Trouble conditions fo...

Страница 19: ...ress 0 1 2 3 4 5 6 Address 0 1 2 3 4 5 6 001 041 081 002 042 082 003 043 083 004 044 084 005 045 085 006 046 086 007 047 087 008 048 088 009 049 089 010 050 090 011 051 091 012 052 092 013 053 093 014 054 094 015 055 095 016 056 096 017 057 097 018 058 098 019 059 099 020 060 100 021 061 101 022 062 102 023 063 103 024 064 104 025 065 105 026 066 106 027 067 107 028 068 108 029 069 109 030 070 110...

Страница 20: ... 2008 Bosch Security Systems Inc F01U081956 01 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 USA www boschsecurity com ...

Отзывы: