background image

Safety Precautions

Installation should be performed by qualified
service personnel only in accordance with the
National Electrical Code or applicable local
codes.

Power Disconnect. Units with or without 
ON-OFF switches have power supplied to the
unit whenever the power cord is inserted into the
power source; however, the unit is operational
only when the ON-OFF switch is in the ON
position. The power cord is the main power
disconnect for all units. 

CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE PARTS
INSIDE.  REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

This symbol indicates the presence of
uninsulated “dangerous voltage” within the
product’s enclosure that can cause an electric
shock.

This symbol indicates the presence of
important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.

For Indoor Product

1.

Water and Moisture

- Do not use this unit near

water - for example, in a wet basement, in an
unprotected outdoor installation or in any area
classified as a wet location.

2.

Object and Liquid Entry

- Never push objects of

any kind into this unit through openings, as they
might touch dangerous voltage points or create
short circuits, resulting in a fire or electrical
shock. Never spill liquid of any kind on the unit.

3.

Power Cord and Power Cord Protection

- For

units intended to operate with 230VAC, 50Hz,
the input and output power cord must comply
with the latest versions of IEC Publication 227 or
IEC Publication 245. 
Power supply cords should be routed so they are
not likely to be walked on or pinched. Pay
particular attention to location of cords and plugs,
convenience receptacles, and the point of exit
from the appliance.

4.

Overloading

- Do not overload outlets and

extension cords; this can result in a risk of fire or
electrical shock.

For Outdoor Product

Power Lines

- An outdoor system should not be

located in the vicinity of overhead power lines,
electric lights or power circuits, or where it may
contact such power lines or circuits. When
installing an outdoor system, extreme care should
be taken to keep from touching power lines or
circuits, as this contact might be fatal. U.S.A.
models only - refer to the National Electrical
Code Article 820 regarding installation of CATV
systems.

For Rack-mount Product

1.

Ventilation

- Do not place this equipment in a

built-in installation or rack, unless proper
ventilation is provided, or the manufacturer's
instructions were followed. The equipment must
not exceed its maximum operating temperature
requirements.

2.

Mechanical Loading

- When rack-mounting the

equipment, ensure that a hazardous condition is
not created by uneven mechanical loading.

2

Содержание DMExPCHxx

Страница 1: ...Instruction Manual EN Integrated Fixed Dome DME Series ...

Страница 2: ...on completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from battery power refer to the operating instructi...

Страница 3: ...a fire or electrical shock Never spill liquid of any kind on the unit 3 Power Cord and Power Cord Protection For units intended to operate with 230VAC 50Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 Power supply cords should be routed so they are not likely to be walked on or pinched Pay particular attention to location of cor...

Страница 4: ...die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Precauciones de Seguridad Atención la instalación la debe realizar únicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su país Desconexión de la alimentación Las unidades con o sin interruptores de encendido apagado reciben alimentación eléctrica siempre que el ca...

Страница 5: ...sse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Medidas de Segurança Atenção a instalação deve ser executada apenas por técnicos qualificados da assistência de acordo com o código eléctrico nacional ou os códigos locais aplicáveis Corte de corrente As unidades com ou sem interruptores O...

Страница 6: ...In ceiling Model DMExRx Series 6 4 2 Pendant Model DMExPx Series 8 4 2 1 Conduit Pipe Mounting 8 4 2 2 Wall Mounting 8 4 3 Camera Adjustments 9 4 4 Remote Video Setup 10 5 CAMERA LENS SETTINGS 11 5 1 Line Lock Phase Backlight Compensation Setting 11 6 SPARE PARTS ACCESSORIES 12 ...

Страница 7: ...ce the customer should contact the nearest Bosch Security Systems Service Center for return authorization and shipping instructions Service Centers U S A phone 800 366 2283 or 717 735 6638 fax 800 366 1329 or 717 735 6639 email BoschCCTVparts ca slr com Canada 514 738 2434 Europe Middle East Asia Pacific Region 32 1 440 0711 For additional information see www boschsecurity com 4 INSTALLATION ATTEN...

Страница 8: ...ion fold out and screw down to secure unit Figure 1 Ceiling Mount Power Video Connections 2 Install the base assembly box into the precut hole until the base s flange hits the ceiling Tighten the three screws that serve to lower the mounting clamps to grab on to the ceiling Be sure the clamps are secure against the ceiling see Figure 2 3 Adjust the camera module for proper viewing angle See Sectio...

Страница 9: ...shown in Figure 3 Conduit and conduit nuts are not supplied Figure 3 Pendant Pipe Mount Installation 3 Route power video cables to the terminal block and BNC connector located on the back of the housing and make proper connections See Figure 1 4 Attach base camera lens unit to pendant cap by lining up and joining the cap s four studs to the slots located on the back of the base unit Twist the hous...

Страница 10: ...cluded Electrical Box Mounting Option Hole pattern in mounting plate matches a North American double outlet electrical box Use four screws included to secure the wall arm to the box Make sure box is securely anchored Figure 4 Pendant Wall Mount Installation 4 3 Camera Adjustments 1 The camera can manually pan tilt or rotate 360 degrees See Figure 5 for a diagram of these adjustments Figure 5 Camer...

Страница 11: ...tor Refer to the following steps for this procedure 1 After the power and video connections are made to the camera and the dome is mounted correctly connect the setup coax cable with BNC located next to the camera lens module to the remote monitor See Figure 6a for an example of a simple setup configuration Figure 6a Example of Setup Configuration Using Remote Monitor 2 Disconnect the video connec...

Страница 12: ...k is on the backlight compensation is off and the white balance is on Figure 7 Camera Assembly CAMERA MODULE ADJUSTMENTS AND CONNECTIONS A Power Block 1 Supply 2 Secondary GND Do not connect 3 Supply Supply accepts 24 Vac or 12 Vdc polarity independent galvanically isolated from video GND B Video Cable Output Connection C DC Iris Cable Connection D Vphase Adjustment Adjust control until desired se...

Страница 13: ...2 Pendant Cap 315 3741 003 Mounting Clamps Screws 3 sets 315 3741 004 Lens 3 8 mm DC Iris LEN 3 08 0AI T Lens 5 50 mm DC Iris LTC 3374 20 Accessories Description Part No Conduit Adapter for 1 inch Conduit 315 3741 005 Plenum Rated Backbox DMEBX Plenum Rated Backbox and Support Rails DMEBXR Wall Mount MTDMEW 12 ...

Страница 14: ...13 ...

Страница 15: ...14 ...

Страница 16: ... security sales us bosch com http www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 0 40 27 83955 Fax 31 0 40 27 86668 emea securitysystems bosch com http www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch ...