Series Commissioning
6–2
1070 066 028-101 (01.05) GB
3. The modified file may be transmitted to the drive, however, it has to be
saved beforehand.
Select the menu sequence: FILE
"
SAVE
.
If the error ”Module1: Date of Axx currently write-protected” is dis-
played during transmission, the write protection was not disabled
by pressing the boot button (cf. page 5–1).
4. Click on the ”Set” command button. (cf. figure above).
During the write process, the 7-segment display on the inverter shows
(serial transmission).
L
Close the editor.
L
If necessary, perform a setpoint calibration (see page 5–11).
6.2
Couple next drive
L
Remove the connection line from X99 and plug it to X99 of the next module to
be commissioned.
L
Initialize the new module:
D
with menu sequence
CONTROL
"
RESET DSS,
–or–
D
by clicking on
in the icon bar.