Resolution:
–
for analog cameras, set the video resolution to 4CIF (704 x 576/480 PAL/NTSC),
2CIF (704 x 288/240 PAL/NTSC), or CIF (352 x 288/240 PAL/NTSC).
–
for IP cameras, set the video resolutions from which to choose in the
Camera
resolutions
field in the
Video & Audio
/
General
tab.
–
Quality:
–
set the video quality setting to High, Medium or Standard.
–
Frame rate:
–
set the video frame rate to 25/30, 12.5/15, 6.25/7.5, 3.125/3.75 or 1/1 ips (images
per second in PAL/NTSC). For IP cameras, the frame rate value is limited so that the
resulting
Current
bitrate value does not exceed the
Ceiling
value.
For analog cameras:
–
Record audio:
–
check to enable audio recording.
–
Audio quality:
–
set the audio quality to High, Medium or Standard.
For IP cameras:
–
The current bit rate is shown.
–
The bit rate ceiling is shown.
Note:
For the most efficient image compression, avoid camera noise by making sure that the camera
has been set up correctly and enough lighting is available. In addition, ensure that the camera
is mounted so that it does not shake due to wind or other influences.
6.4.2
Contact
The fields have the same parameters as those under the Normal tab. Additional fields are
present for contact recording.
–
Contact recording:
–
Fixed duration
- activates recording for the set duration from the start of the event.
–
F Post
- activates recording as long as the event is active and continues
after the event becomes inactive for the time set in the duration field.
–
Follows
- activates the recording only as long as the event is active.
–
No recording
–
Set the duration time in minutes and seconds.
6.4.3
Text
The fields have the same parameters as those under the Normal tab. Additional fields are
present for text recording.
–
Text recording:
–
Fixed duration
- activates recording for the set duration from the start of the event.
–
No recording
–
Set the duration time in minutes and seconds.
6.4.4
Motion
The fields have the same parameters as those under the Normal tab. Additional fields are
present for motion recording.
–
Motion recording:
–
Fixed duration
- activates recording for the set duration from the start of the event.
–
No recording
–
Set the duration time in minutes and seconds.