background image

en

    Important safety information

4

(

Important safety 

information

Important safety information

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Risk of fire! 

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire! 

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire! 

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire! 

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire! 

Operating several gas burners at the same 

time gives rise to a great deal of heat. A 

ventilation appliance installed above the 

cooker may become damaged or catch fire. 

Never operate two gas burners 

simultaneously on the highest flame for 

longer than 15 minutes. One large burner of 

more than 5 kW (wok) is equivalent to the 

power of two gas burners.

:

Warning – Risk of burns! 

The accessible parts become very hot when in 

operation. Never touch hot parts. Keep 

children at a safe distance.

Содержание DHU63.HQ

Страница 1: ...3FHJTUFS RXU QHZ GHYLFH RQ 0 RVFK QRZ DQG JHW IUHH EHQHILWV CPTDI IPNF DPN XFMDPNF en Instruction manual Extractor hood Extractor hood DHU63 HQ DHU635HB DHU935HB DHU636CQI ...

Страница 2: ......

Страница 3: ...his appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by child...

Страница 4: ...ase consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 mont...

Страница 5: ...sive cleaning agents Never use strong and abrasive cleaning agents Risk of damage from returning condensate Install the exhaust duct in such a way that it falls away from the appliance slightly 1 slope 7Environmental protection EnvironmentalprotectionYour new appliance is particularly energy efficient Here you can find tips on how to save even more energy when using the appliance and how to dispos...

Страница 6: ...ual features are described which do not apply to your appliance Note Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Note Fold the glass cover forwards This increases the extraction area Control panel Setting the fan Note Always adjust the fan strength to meet cu...

Страница 7: ...ean the grease filter at least every 2 months Never operate the appliance without the grease filter Note Only use genuine replacement filters This ensures optimal performance of the appliance 1 Press the locks on the left and right of the filter grille 2 Swing the filter grille down 3 Position the filter grille at an angle and remove it 4 Remove the wires and then the metal filter mat 5 After remo...

Страница 8: ...hreaded joints on the activated charcoal filter covers 3 Remove the activated charcoal filter 4 Insert the new activated charcoal filter 5 Screw the covers into place 6 Install the metal grease filter see the section entitled Installing the metal grease filter 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please read the following notes before calling the after sales...

Страница 9: ...ch on the fuse again Replace the bulb with one of the same type Voltage 230 V Power Max 28 W Thread E14 4Customer service CustomerserviceWhen calling us please give the product number E no and the production number FD no so that we can provide you with the correct advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can...

Страница 10: ...en Accessories 10 _Accessories AccessoriesActivated charcoal filter DHZ2701 ...

Страница 11: ...6 ...

Страница 12: ... QQMJBODFT 4FSWJDF UHH DQG HDV UHJLVWUDWLRQ DOVR RQ PRELOH SKRQHV XXX CPTDI IPNF DPN XFMDPNF PPLJOH GPS IFMQ PV MM GJOE JU IFSF SHUW DGYLFH IRU RXU RVFK KRPH DSSOLDQFHV QHHG KHOS ZLWK SUREOHPV RU D UHSDLU IURP RVFK H SHUWV LQG RXW HYHU WKLQJ DERXW WKH PDQ ZD V RVFK FDQ VXSSRUW RX XXX CPTDI IPNF DPN TFSWJDF POUBDU EBUB PG BMM DPVOUSJFT BSF MJTUFE JO UIF BUUBDIFE TFSWJDF EJSFDUPSZ 3PCFSU PTDI BVTHFS...

Отзывы: