background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 

Program Entry Guide 

Control Panel 

 

D9112B 

 

Содержание D9112B

Страница 1: ...EN Program Entry Guide Control Panel D9112B ...

Страница 2: ...ntence For example Phone 1 is the first programming prompt in the Phone section of the program References to modules categories and sections of the program are shown in italic letters For example Phone is the first programming category in the Panel Wide Parameter programming module Use the D9112B Program Record Training Sheet P N 74 06447 000 to review default program entries as you read this guid...

Страница 3: ...er Parameters 20 Printer Address 20 P Scope 20 P Area Assign 21 P Supervision 21 P Prt Points 21 P Prt O C 21 P Prt Non Alrm 21 1 5 RAM Parameters 22 RAM Passcode 22 Log Full 22 RAM Call Back 23 RAM Line Monitor 23 Answer Armed 23 Answer Disarmed 23 Ram Ph 24 2 0 Area Wide Parameters 25 2 1 Area Parameters 25 Area 25 A Area On 25 A Acct Number 25 A FA Bypass Max 25 A Delay Res 26 A Exit Tone 26 A ...

Страница 4: ...ace 45 3 1 Commands 45 3 2 Command Menu and Custom Functions 45 3 3 Cmd Center Function 46 3 4 Authority Lvl Assign 46 Disarm 47 L Disarm 47 Master Arm 48 L Master Arm 48 Mstr Arm Inst 49 L Master Arm Inst 50 Perim Instant 50 L Perim Inst 51 Perim Delay 51 L Perim Delay 52 Watch Mode 53 L Watch Mode 53 Perim Partial 53 L Perim Partial 53 View Area Stat 53 L View Area Stat 53 View Event Mem 53 L Vi...

Страница 5: ... UW Access Window Stop 64 5 1 Holiday Indexes for User Access Windows 65 UW Xept Holiday 65 UW Holiday 1 65 UW Holiday 2 65 UW Holiday 3 65 UW Holiday 4 65 6 0 Passcode Worksheet 66 Duress 66 User 67 U Passcode 67 U User Window 67 U Area 1 Auth 68 U Area 2 Auth 68 U Area 3 Auth 68 U Area 4 Auth 68 U Area 5 Auth 68 U Area 6 Auth 68 U Area 7 Auth 68 U Area 8 Auth 68 7 0 Point Index 69 Point Index 69...

Страница 6: ...nel Wide Relays 85 Printer 17 Fail 85 Printer 18 Fail 85 Printer 19 Fail 85 AC Failure 85 Battery Trouble 85 Phone Fail 85 Comm Fail 85 Log Full 86 Summary Fire 86 Summary Alarm 86 Summary Fire Tbl 86 Summary Trouble 86 10 0 Skeds 86 Sked Number 86 S Function Code 87 S Time 92 S Date 92 S Sunday 92 S Monday 93 S Tuesday 93 S Wednesday 93 S Thursday 93 S Friday 93 S Saturday 93 S Xept Holiday 93 S ...

Страница 7: ... Phone Routing Worksheet Skeds 15 Table 12 Phone Routing Worksheet Test Stat Rpt Test and Status Reports 16 Table 13 Phone Routing Worksheet RAM 16 Table 14 Phone Routing Worksheet Power Phone17 Table 15 Phone Routing Worksheet Service 17 Table 16 Verify Time Examples 27 Table 17 Programming for Two Opening Windows on the Same Day 37 Table 18 Programming to Link Two Days Over Midnight 37 Table 19 ...

Страница 8: ...mm Fail event is placed in the event log if Comm Fail occurs on both the primary and backup phones Comm Fail does not report to the D6500 except during Test reports You must program Expand Test Rpt YES A Comm Restoral event generates after another reporting event successfully transmits to any of the receiver phone numbers This Comm Restoral report is sent according to the routing for Power Phone i...

Страница 9: ...ult Blank Selection Up to 24 characters do not enter SPACE See explanation of Phone 1 This number is Phone 4 referenced in Phone Routing Parameters Modem Format The central station receiver format for transmitting reports Modem Format provides many reporting advantages over the BSFK format see the D6500 Report Directory for more information about the effect of reporting formats Default Yes Selecti...

Страница 10: ...e converted when this item is YES See the D6500 MPU Program Entry Guide CompOut program item No The D9112 does not send the flag The D6500 outputs point numbers as 001 to 135 rather than 100 to 815 and User ID numbers as 000 to 099 rather than 000 to F08 as indicated in Table 1 and Table 2 Table 1 Modem II Communication Format Data User ID Numbers Point User Flag No Yes 000 000 001 to 005 001 to 0...

Страница 11: ...tings in ten sec increments Phone line trouble responses Command centers display SERVC PH LINE and sound the trouble tone Restoral reports identify the previously failed line after it restores when a single phone line is used if Power Phone is enabled in Phone Routing Trouble and restoral events are reported if Power Phone is enabled in Phone Routing a Dual Phone Line Module is installed and one o...

Страница 12: ...ting No Do not send Cancel reports to the phone s Ground Start Use only when the panel is connected to Ground Start telephone lines Some newer ground start telephone exchange switches require a shorter amount of time to initiate a dial tone If the panel cannot initiate a dial tone on the ground start line with the default Long setting try the Short setting Both lines must be of the same operation ...

Страница 13: ... a duplicate report does not generate any user notification or central station report Press the SPACE bar to scroll through the selections Press ENT when the correct selection appears in the display 0101 0101 0101 If the D5200 buzzes when you make an entry you made a routing error If you enter the same route on two different phones for a particular Report Group the D5200 buzzes When it buzzes it a...

Страница 14: ...ing Alarm x x User Alarm CMD 7 Cancel Alarm Table 7 Phone Routing Worksheet Trouble Non Fire Trouble Report Type Phone 1 Phone 2 Phone 3 Phone 4 Fire Trouble x x Fire Walk Start x x Missing Fire x x Fire Restoral after Trouble or Missing x x Table 8 Phone Routing Worksheet Diagnostics Report Type Phone 1 Phone 2 Phone 3 Phone 4 SDI Failure Parm Cksum Fail SDI Restoral Re boot Watchdog Reset Table ...

Страница 15: ...rim Dlay Armed F Close Early x x F Close Pr Dlay x x Command Bypass x x Swinger Bypass Early to Open x x Fail to Open x x Closing Late x x Fail to Close Was Force Armed x x F Close Late x x Forced Point x x Sked Bypass Opening Report x x Point Closing x x Closing Report x x Perim Inst Armed Forced Close F Close Pr Inst x x Point Bypass x x RAM Bypass x x Table 11 Phone Routing Worksheet Skeds Repo...

Страница 16: ...hown Log Threshold Prog Access OK SDI Failure Battery Missing Pt Bus Trouble AC Failure Log Overflow Bad Call to RAM Comm Failure Battery Low User Tamper Params Bad Cksm Status Report includes area events as shown S Alarm S Opening S Perim Delay Point Bypass S Trouble S Closing S Perim Instant Forced Point Table 13 Phone Routing Worksheet RAM Report Type Phone 1 Phone 2 Phone 3 Phone 4 Log Thresho...

Страница 17: ...ult 1 Selection 1 to 4 Enter the phone s number for which you are selecting report group routing Ph Fire Alarm Res Default Blank Selection Blank P B or D See the introduction to Phone Routing for a description of the selections Ph Tbl Res Default Blank Selection Blank P B or D See the introduction to Phone Routing for a description of the selections Ph Alarm Res Cncl Default Blank Selection Blank ...

Страница 18: ...ection Blank P B or D See the introduction to Phone Routing for a description of the selections If a Parameter Checksum Fail Parm Cksum Fail report is received the user can silence the panel s buzzer but cannot clear the system trouble display To correct a Parameter Checksum Fail condition re load the program into the panel using RAM or the D5200 Ph Relay Default Blank Selection Blank P B or D See...

Страница 19: ... for Power Phone events AC Failure is reported as Trouble Zone 0 when transmitting in BFSK No AC Failure and AC Restoral reports are NOT sent when they occur They can still be sent with subsequent reports if AC Tag Along is programmed YES AC Tag Along Send AC Failure report as an additional message tag along with other reports To comply with UL 864 requirements for Commercial Fire Systems program ...

Страница 20: ...ess it is disabled by AC Battery Buzz see AC Battery Buzz 1 4 Printer Parameters Up to three D9131 Printer Interface Modules can be connected to the D9112 s SDI bus Each printer is identified by an address of 17 18 or 19 Options are available for Routing reports and area assignments Printer Address Default 17 Selection 17 18 or 19 The printer address you are programming P Scope Press the SPACE bar...

Страница 21: ...y can be assigned to indicate printer trouble see Relay Assignments P Prt Points Point events include every event that can be generated by a point Events include all of the events listed in the Fire Alarm Restoral Fire Tbl Rest AlarmRest Cancel and Trouble logs shown in the Phone Routing Worksheet Default Yes Selection Yes or No Yes Print point events according to the Printer Scope and Area Assign...

Страница 22: ...h When the panel connects to RAM it waits for instructions from the RAM to download its event log See the RAM II Operation and Installation Guide for further information on call pick up procedures If communication with RAM is not successful or if there is no phone number programmed in RAM Ph the panel sends a Log Threshold and a Bad Call to RAM report to the D6500 This indicates that the log is fi...

Страница 23: ...all Back is programmed YES the panel hangs up on the phone after the RAM tone and a proper RAM passcode is identified then it calls the RAM phone number No The item should be programmed NO if you are not using RAM This item should be programmed NO if the panel is not sharing the phone line with an answering machine This item should be programmed NO if it causes false seizures of the phone line Thi...

Страница 24: ...es with ten min intervals between each attempt before generating a Bad Call to RAM report and abandoning the effort Note Command 43 Dialing Exception When dialing the RAM phone number in response to the Command 43 CALL RAM option the D9112 makes only one attempt If it does not make contact with RAM the panel abandons the effort and creates a Bad Call to RAM report The D9112 is pre programmed with ...

Страница 25: ... This program item determines the account number reported for this area An account number must be assigned to each active area Account numbers are used to group areas together Each area can have a different account number or several areas may share the same account number The D9112 uses the account number as a reference for arming and command center text displays Default 0000 Selection For BFSK 00...

Страница 26: ... area is disarmed it will be OFF when the area is disarmed Note Watch Mode does not work while the area is perimeter armed A Verify Time Default 60 Selection 10 to 60 sec Alarm Verification is designed for use with smoke detectors to reduce the number of false fire alarms When Verify Time is programmed the panel can double check smoke detector point activations before generating alarm signals Note...

Страница 27: ...1 to 8 Enter the area number you are programming A Fire Time Default 6 Selection 1 to 90 Enter the number of minutes the bell rings for fire alarm points The bell output begins as soon as the fire alarm occurs When the panel s internal clock begins a new minute it considers the first minute expired It shuts off the bell when the programmed number of minutes expire If a passcode is entered to silen...

Страница 28: ...nds the timing and shuts off the bell when the programmed number of minutes expires If a passcode is entered to silence the bell before the time expires and Cancel report is programmed YES in Phone a Cancel report is generated and sent to the same phone that the alarm message is routed to The output for the alarm bell is determined by programming in the Relays section of the program Relay A is the...

Страница 29: ...101 0101 0101 Bell test may be erratic If several areas programmed for bell test are armed at the same time and all the areas share the same alarm bell relay the relay operation may be erratic or longer than expected For example if all eight areas are programmed for bell test share the same alarm bell relay have the same exit delay time and are armed at the same time the bell may ring for as long ...

Страница 30: ...account are disarmed each area will generate an Area Opening report Additional Opening Closing Supervision Features This section of the program also provides several other features you can use to supervise opening and closing activity by area Auto Close Fail to Open and Fail to Close all work independently of the A Acct O C feature To use these features however you must program O C Windows Area De...

Страница 31: ...Authority Lvl Assign section L Area O C prompt Note If a passcode is not required for arming or disarming and this item is YES the area sends Opening and Closing reports Since there is no need to enter a passcode there is no authority level screening to prevent the report from being sent Opening Closing Window The second factor is whether or not an opening or closing window is in effect at the tim...

Страница 32: ...ort Default No Selection Yes or No Yes Restrict Opening and Closing reports for this area A Area O C must be programmed YES to generate Restricted Opening and Closing reports Note If a passcode is not required for arming or disarming and this item is YES the area only sends Restricted Opening and Closing reports In this case restricted reports are sent without User ID Opening Closing Window does n...

Страница 33: ...tem is YES the area sends Perimeter Opening and Closing reports In this case the report is sent without User ID Opening Closing Window does not affect this report Windows do not prevent Perimeter Opening and Closing reports from being sent There are no reports for Perimeter Partial arming Command 8 No This area can not send Perimeter Opening and Closing reports Even if L Perimeter O C is Enabled f...

Страница 34: ...ou to determine if Fail to Open reports are sent Default 0 Selection 0 or 1 Yes Fail to Open reports are sent to the central station logged and recorded on a local printer if installed at the end of the opening window if the area has not been disarmed Normal Opening and Closing reports do not need to be programmed to use this feature No No Fail to Open reports or log events are generated A Fail To...

Страница 35: ... on the Program Record Sheet provided with the D9112 These numbers appear in D6500 reports and local printer reports when the window Begin Time executes Window Default 1 Selection 1 to 16 Enter the window number you want to program W Sunday This prompt and the next six days of the week prompts select the days of the week that the opening and or closing windows are active Exceptions To prevent the ...

Страница 36: ...arming the area after the Open Window Stop and the next window s Open Early Begin time or midnight whichever comes first generates an Opening report and adds a Late to Open modifier If Disable O C in Window is NO disarming the area generates an Opening report without the early or late modifier regardless of when the area is disarmed When you are programming multiple windows to activate on a single...

Страница 37: ...This program item is one of three required to create a closing window To finish programming a closing window Close Window Start and Close Window Stop must be programmed Use Close Early Begin to set the time you want the panel to look for a closing window When Opening and Closing reports are enabled arming the area between midnight and the Close Early Begin time generates a Closing report In additi...

Страница 38: ...s in ten min if the area is not armed See Close Early Begin for report feature explanations W Close Window Stop Default _ _ _ _ Selection HH MM hours and minutes Enter the time that you want the panel to start the closing window The window stops at the end of a minute If the area is not armed by the time the Close Window Stop time expires the panel generates a Fail to Close report if enabled in Fa...

Страница 39: ...Holiday Index with the days of the year you want the window to be active 2 4 3 Holiday Indexes for O C Windows You can enable up to four Holiday Indexes for use with Opening Closing Windows Enable at least one Holiday Index if W Xept Holiday is programmed YES for this window or if you want this window to activate only on specific dates Holidays are programmed in the Holiday Indexes section of the ...

Страница 40: ... 4 5 6 7 8 10 S M T W T F S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Yes No 1 2 3 4 1 2 3 4 5 6 7 8 11 S M T W T F S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Yes No 1 2 3 4 1 2 3 4 5 6 7 8 12 S M T W T F S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Yes No 1 2 3 4 1 2 3 4 5 6 7 8 13 S M T W T F S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Yes No 1 2 3 4 1 2 3 4 5 6 7 8 14 S ...

Страница 41: ...liday Index Area s 3 S M T W T F S 02 30 02 45 03 00 03 05 03 1 5 03 30 Yes No 1 2 3 4 1 2 3 4 5 6 7 8 Program at least one day as Yes Day s of the week but NOT on holidays Yes Select at least one index Program at least one area as Yes Monday and Wednesday In between 2 45 and 3 00 a m Out between 3 15 and 3 30 a m Another alternative for delivery schedules is to automatically bypass specific point...

Страница 42: ...th the same address echo the operation of all other command centers with the same address in other words they all show the same displays and emit the same tones at the same time System Security Notice Install unsupervised command centers inside the protected area All equipment installed outside of the protected area should be enclosed in tamper resistant housing CC Scope Scope determines if the co...

Страница 43: ...ers when the area has faulted controlled points The text for each area is programmed separately so each area can have a custom display Check the Program Record Training Sheet P N 74 06447 000 for default text Area Is Off Default See Program Record Sheet Selection 16 alphanumeric characters enter alphabetic characters A to Z in capital letters Note Period comma percent parenthesis equal greater les...

Страница 44: ...s for the function Custom Function Default 128 Selection 128 to 143 Enter the Custom Function number you want to program You can program up to 16 Custom Functions which are numbered 128 to 143 CF Text Default See Program Record Sheet Selection 16 alphanumeric characters enter alphabetic characters A to Z in capital letters Note Period comma percent parenthesis equal greater less than exclamation a...

Страница 45: ...ories and Custom Function in the Command Center module to enable user interface features There are two ways to access command center functions Commands and the Command Menu The Security System User s Guide provides instructions on how to access the Command Menu along with step by step instructions for basic command center functions The Security System Owner s Manual explains the more advanced feat...

Страница 46: ...nd when you are learning how to program the panel 0101 0101 0101 Cmd Center Function prompts are shown in plain boxes Authority Lvl Assign prompts are shown in dashed boxes In the D5200 programmer the prompts for Cmd Center Functions and Authority Lvl Assign appear in separate sections of the User Interface module See the Security System User s Guide for descriptions and operating instructions for...

Страница 47: ... How Command Center Scope affects area execution An Area Command Center can execute this function only in the area where the command center is assigned An Account command center can execute this function in all areas in the account where the user has authority A Panel Wide Command Center can execute this function in all areas in the panel where the user has authority Default P Selection P P Passco...

Страница 48: ...ns Area O C and Restricted O C determines whether Opening and Closing reports can be generated for a particular area P Passcode required When the passcode is entered at the command center the panel checks the authority level The panel only arms areas where the passcode is authorized that are within the Scope of the command center The command center display shows the areas it is arming 0101 0101 01...

Страница 49: ...command center can execute this function only in the area where the command center is assigned An Account command center can execute this function in all areas in the account where the user has authority A Panel Wide command center can execute this function in all areas in the panel where the user has authority Default Blank Selection Blank E or P Blank Disable the function panel wide Accessing th...

Страница 50: ...rim Instant Perimeter Instant Arm COMMAND 2 This command center function arms all perimeter points see Point Index Point Type in the area where the command center is assigned No entry or exit delays are provided with this arming function Default P Selection Blank E or P Blank Disable the function panel wide Accessing the function using a command the Command Menu or a custom function displays NO AU...

Страница 51: ...im Delay Perimeter Delay Arm COMMAND 3 This command center function arms all perimeter points see Point Index Point Type in the area where the command center is assigned No entry or exit delays are provided with this arming function Default Blank Selection Blank E or P Blank Disable the function panel wide Accessing the function using a command the Command Menu or a custom function displays NO AUT...

Страница 52: ... E Enable this function for Authority Level specified When the passcode is entered at the command center the panel checks the authority level The panel executes the function only in areas where the passcode is authorized Programming in O C Options Perimeter O C determines whether Perimeter Closing reports can be generated for a particular area Whether Perimeter Closing reports and subsequent Openi...

Страница 53: ...or descriptions of selections L Perim Partial Default See Program Record Sheet Selection Blank or E Perimeter Partial Arm See Authority Level Selections in the introduction to the Authority Lvl Assign programming module for descriptions of selections View Area Stat Default P Selection Blank E or P View Area Status This command center function allows the user to view the armed status of areas other...

Страница 54: ...amming module for descriptions of selections L Walk Test Default See Program Record Sheet Selection Blank or E Walk Test See Authority Level Selections in the introduction to the Authority Lvl Assign programming module for descriptions of selections Fire Test Default P Selection Blank E or P Fire Test COMMAND 5 8 Test 24 Hour points in areas within the Scope of the command center where the functio...

Страница 55: ...enter warning tones Chg Display also turns on the continuous time and date display The time and date display clears when a higher priority message needs to be displayed See Command Center Function Selections in the introduction to the Command Center Functions programming module for descriptions of selections L Chg Display Default See Program Record Sheet Selection Blank or E Change Display See Aut...

Страница 56: ...iptions of selections L Del Passcode Default See Program Record Sheet Selection Blank or E Delete Passcode See Authority Level Selections in the introduction to the Authority Lvl Assign programming module for descriptions of selections Extend Close Default P Selection Blank E or P Extend Close Change the expected closing time for the area where the function is entered The window cannot be adjusted...

Страница 57: ...pecial manually activated alarm This function generates an Alarm report each time it is activated but only one alarm appears in the alarm memory count at the local area command centers If this function is activated in more than one area within the scope of the command center the alarm memory count is increased See the Point Assignment module Command 7 section for additional programming requirement...

Страница 58: ...command center where the function is entered see Cmd Cntr Assignment See Relays section for information about Reset Sensors relay activation See Command Center Function Selections in the introduction to the Command Center Functions programming module for descriptions of selections L Reset Sensors Default See Training Sheet Selection Blank or E Reset Sensors See Authority Level Selections in the in...

Страница 59: ...e Program Record Sheet Selection Blank or E Display Software Revision See Authority Level Selections in the introduction to the Authority Lvl Assign programming module for descriptions of selections Service Walk Default P Selection Blank E or P Service Walk Test This test is similar to a Walk Test The Service Walk test can also display points from all disarmed areas in the panel when the Service W...

Страница 60: ...s COMMAND 5 2 A panel wide function that can be executed from any command center assigned to an area where the user has authority Use to make adjustments to Skeds numbered 1 to 17 See the Security System Owner s Guide for operating instructions See Command Center Function Selections in the introduction to the Command Center Functions programming module for descriptions of selections L Change Skeds...

Страница 61: ...red to arm or disarm restricted openings and closings are disabled for this user E If a passcode is required to arm or disarm send only restricted openings and closings for users with this authority level L Area O C must be enabled A Area O C and A Restricted O C must be programmed YES in Open Close Options L Perimeter O C Determines if Perimeter Opening and Closing reports are sent to the central...

Страница 62: ...rea O C must be programmed YES in Open Close Options L Area O C must be enabled for this authority level 4 0 Command Menu Use this programming category to create a list of functions that appear in command center displays when the user presses the ESC MENU key while the command center is displaying idle text The Command menu is customized according to command center address Each command center addr...

Страница 63: ... Address 1 to M CC Address 8 NO or change the Function number M CC Address 1 Default See Program Record Sheet Selection Yes or No Should this menu item appear in Command Menu at Address 1 M CC Address 2 Default See Program Record Sheet Selection Yes or No Should this menu item appear in Command Menu at Address 2 M CC Address 3 Default See Program Record Sheet Selection Yes or No Should this menu i...

Страница 64: ... Yes or No Is this User Window active on Wednesday UW Thursday Default No Selection Yes or No Is this User Window active on Thursday UW Friday Default No Selection Yes or No Is this User Window active on Friday UW Saturday Default No Selection Yes or No Is this User Window active on Saturday UW Access Window Start Default _ _ _ _ Selection HH MM hours and minutes Enter the time of day that the win...

Страница 65: ...o Yes Do not activate this window on holidays To use this selection the window must be programmed to activate on at least one day of the week and at least one Holiday Index must be used with this window No A holiday does not prevent this window from activating Use this selection if the User Window is only needed on certain days of the year or if you want the User Window to activate regardless of t...

Страница 66: ...er 20 to 29 User 30 to 39 User 40 to 49 User 50 to 59 User 60 to 69 User 70 to 79 User 80 to 89 User 90 to 99 BFSK Report 0 BFSK Report 1 BFSK Report 2 BFSK Report 3 BFSK Report 4 BFSK Report 5 BFSK Report 6 BFSK Report 7 BFSK Report 8 BFSK Report 9 Duress Create a secondary passcode This secondary passcode has all the features of the user s primary passcode In addition it can send DURESS alarm if...

Страница 67: ...if Duress is disabled For example once a passcode of 654321 is entered 654322 654323 654320 and 654329 can not be entered The D9112 generates a Usr Code Tamper report after six consecutive attempts to enter a passcode that does not exist in the system There is no time limit for the consecutive attempts but all attempts must be made from the same command center address After a valid passcode is ent...

Страница 68: ...r for this area Blank means the user has no authority in this area U Area 3 Auth Default Selection 1 to 14 or Blank Assign an authority level to the user for this area Blank means the user has no authority in this area U Area 4 Auth Default Selection 1 to 14 or Blank Assign an authority level to the user for this area Blank means the user has no authority in this area U Area 5 Auth Default Selecti...

Страница 69: ...rammed to Buzz on Fault When a 24 hour point is bypassed the report should be sent as it occurs If the area contains all 24 hour points the area is never armed or disarmed therefore a deferred bypass report is not sent Note 24 hour protection for fire doors roof hatches and so on Instead of programming this type of protection as a 24 hour point consider using a perimeter point type with a Point Re...

Страница 70: ...area is in entry delay when the interior point trips the panel compares the remaining entry delay time to the time programmed for the interior point If the interior point s entry delay time is less than the remaining time it shortens the entry delay time Delayed points can also initiate an entry tone at the command center see P Entry Tone Off Note In some cases you may need to create an interior p...

Страница 71: ...he area is disarmed The alarm bell silences if an alarm occurred while the area was armed Short A short is a trouble while the area is disarmed A short is an alarm while the area is armed When this point changes from shorted to normal or open it restores but does not send a Restoral report 5 Keyswitch Momentary Used for Area Arming and Disarming Point Response must be programmed 1 Do not connect i...

Страница 72: ...each selection available for controlled non 24 Hour point types and 24 Hour point types Table 30 Point Response Table Pt Response 0 1 2 3 4 5 6 7 8 9 A B C D Controlled Points Armed Open I I I I D D I I D I I I I I Armed Short I I I I I I D D D I I I I I Disarmed Open T T T I I T I Disarmed Short T T T I T I I 24 Hour Points Open I T I T I T Short I I T T I T Key I Instant Alarm D Delayed Alarm T ...

Страница 73: ...high security applications where you do not want to annunciate entry delay Caution The possibility of false alarms increases if the entry delay warning is not used No A tone sounds at command centers when this point initiates entry delay P Silent Bell Default No Selection Yes or No Yes Activate the Silent Alarm relay when this point goes into alarm Command centers do not sound the alarm tone for n...

Страница 74: ...zzer on fault Often invisible points are not programmed to create audible alarms but instead provide a silent alarm output Alarm events from invisible points can be viewed or printed using the event log The relay follows point option does not work for invisible points Do not use this feature with invisible points No Activity from this point is visible at the command centers P Buz on Fault The buzz...

Страница 75: ...o Yes Suppress Alarm Trouble and Restoral reports from this point while the area it is assigned to is disarmed Local annunciation of activity from this point is provided as programmed Note Local While Disarmed does not work with 24 hour points 24 hour points are always armed they are never disarmed To provide 24 hour protection and limit central station Alarm reports 1 Program point Type as 1 peri...

Страница 76: ...ion under all conditions Maintained with Point Response 1 Suppresses alarms and restorals Momentary Suppresses trouble and restorals D279 Suppresses openings and closings No Report events occurring from this point while the area is armed P Disable Restorals Default No Selection Yes or No Yes Disable Restoral reports for this point No Enable Restoral reports for this point When this option is enabl...

Страница 77: ... bypassable perimeter point type with a Point Response of 9 to D 24 hour points do not show faults or bypasses when an arming command is entered but perimeter points do No This point cannot be bypassed or force armed from the command center or RAM II However it can be force armed by automatic arming at the end of the closing window see Opening Closing Auto Close or by a Sked programmed to arm the ...

Страница 78: ...activates the Fire Bell relay programmed in Relay Parameters The amount of time and pattern of relay activation is programmed by area in Bell Parameters Fire Pat If you assign all your Fire points to a single area in a multiple area system install a command center or other annunciator in each area of the system that is capable of annunciating the activity of the Fire points Default No Selection Ye...

Страница 79: ...er in BFSK Relay Point number 72 is invalid Point 72 is reserved for a panel function P Point Index Default See Program Record Sheet Selection Blank or 00 to 31 Use to select one of the 31 Point Index Codes that define the points characteristics and determine how the D9112 responds to various point conditions 0101 0101 0101 Point Index 00 or blank only works with Command 7 and Command 9 It is a si...

Страница 80: ...ecommends you include the point number in custom point text This helps the user for example when viewing events or initiating bypasses and can simplify troubleshooting 8 2 Command 9 Defines how the Command 9 function operates Program this section if User Cmd 9 is enabled in the User Interface module This function generates an Alarm report from the area where the command center is assigned A new re...

Страница 81: ...ed Point Index Default 4 Selection Blank or 00 to 31 Enter the Point Index code used with Command 7 0101 0101 0101 Point Index 00 or blank only works with Command 7 and Command 9 It is a silent invisible reporting point Point Index 00 disables a normal point 0101 0101 0101 Do NOT use a point index with Resettable programmed YES Do NOT use a point index with Swinger Bypass programmed YES BFSK Code ...

Страница 82: ...ems D136 Relays If relay activity is reported to the receiver see Phone Routing on board relays are reported as follows A 253 B 254 C 255 Up to sixteen D8129 OctoRelay Modules can be connected to the D9112 to provide 128 dry contact form C relays You can set DIP switches on each D8129 to use a group of eight numbered relays as shown in the D9112 Operation and Installation Manual 0101 0101 0101 Che...

Страница 83: ...t is assigned for Burglary Bell output in all areas If both a Fire Alarm and a Burglary Alarm are activated at the same time the Fire Alarm has priority When assigning fire points to the area it is recommended that you program the Fire Bell output for a different relay For example program the Fire Bell output for relay B and install a D136 relay in the panel The following point index entry combina...

Страница 84: ... Blank 1 to 128 A B or C Activates when a duress alarm is generated from a command center assigned the specified area A Burg Time must be programmed in Bell Parameters The relay provides steady output and remains active until the bell time expires or the panel is reset Duress is a panel wide function which is enabled in the Passcode Worksheet Reporting can be suppressed by Authority Level A Keypad...

Страница 85: ...r Supervision in Panel Wide Parameter must be programmed YES Printer 19 Fail Default Blank Selection Blank 1 to 128 A B or C Activates when Printer 19 SDI address 19 fails It remains active until the printer responds The printer must be supervised Printer Supervision in Panel Wide Parameter must be programmed YES AC Failure Default Blank Selection Blank 1 to 128 A B or C Activates when the panel r...

Страница 86: ...n the panel is in trouble This relay provides a steady output until the trouble is cleared from alarm memory at the command center Summary Trouble Default Blank Selection Blank 1 to 128 A B or C Activates when any on fire point in the panel is in trouble This relay provides a steady output until the trouble is cleared from alarm memory at the command center 10 0 Skeds Use the Skeds module to progr...

Страница 87: ...ed Default Blank Selection 1 to 15 except 12 Default Description Sub prompt Selection 1 S Area 1 Yes No Arm Area 1 Do not arm Area 1 Arm Area Entries in the Arm Area prompts define the area s this Sked arms The Sked can arm multiple areas If any point is faulted when the Sked executes it is force armed S Area 2 Yes No Arm Area 2 Do not arm Area 2 S Area 3 Yes No Arm Area 3 Do not arm Area 3 S Area...

Страница 88: ...f Bypass reports are enabled in the Point Index assigned to the point The Sked can bypass one point regardless of the area s armed state 4 Unbypass a Point The entry in the Unbypass Point prompt defines the point this Sked unbypasses The Sked can unbypass one point regardless of the area s armed state The point can be bypassed only if Bypassable is YES in the Point Index assigned to the point The ...

Страница 89: ... S Area 8 Yes No Unbypass all points in Area 8 Do not unbypass all points in Area 8 6 Relay On The entry in the Relay On prompt defines the relay this Sked activates The Sked can activate one relay S Relay Number Enter a relay number 1 to 128 7 Relay Off The entry in the Relay Off prompt defines the relay this Sked turns off The Sked can turn off only relays that were set by a Sked The Sked can tu...

Страница 90: ...nications Failure AC Failure Battery Missing Battery Low Parameter Checksum Failure The Test report can be deferred if any other report was sent since the last Test report To defer the Test report program Defer Test The Test report can be sent every hour beginning at the time scheduled in S Time To send a Test report every hour program Hourly Rpt S Hourly Report Yes No Send the Test report every h...

Страница 91: ...t the same address at the same time Do not program Skeds to execute at times when a user is likely to be executing functions at the command center If it is necessary to do so there are two ways to work around the situation 1 Program CC at the beginning of the Custom Function Key Strokes entry This aborts the user s function and allows the Sked to execute 2 Program the Sked to execute at an address...

Страница 92: ...he command center using the CHANGE SKEDS function To program a time 1 Press the two digits representing the hour 2 The cursor advances past the colon in the display 3 Press the two digits representing the minutes 4 Press ENT S Date Default _ _ _ _ Selection MM DD or Blank This entry selects the month and day that the Sked operates Date of the Year Sked Type 1 Leave this item blank if this Sked ope...

Страница 93: ...o Do not activate this Sked on Saturdays S Xept Holiday Default No Selection Yes or No Yes Enter YES to prevent this Sked from operating on the holidays programmed in the Holiday Index es selected No Enter NO to have this Sked operate on holidays programmed in the Holiday Index es used with this Sked If no Days of the Week or Date of the Year is programmed this Sked operates only on the holidays p...

Страница 94: ...each of the Holiday Indexes You can program up to four Holiday Indexes in the D9112 Within each index you can select up to 365 dates to be designated as holidays The Holiday Indexes function independently from each other The same day can be programmed in all four schedules Holiday Indexes are used in programming O C Windows User Access Windows and Skeds Date Default _ _ _ _ Selection MM DD This en...

Страница 95: ... you programmed into each of the Holiday Indexes You can view the first 100 dates programmed in each of the indexes Index 1 Days Default Blank Selection Enter Group or Press Press ENTER GROUP to view the dates programmed in Holiday Index 1 Press the key to advance to the next Holiday Index Index 2 Days Default Blank Selection Enter Group or Press Press ENTER GROUP to view the dates programmed in H...