-19-
The
<Signal View 2D>
can be used to locate
closely adjacent objects and to better assess
complicated material structures. Weaker objects
and objects in a row can also be found under
certain circumstances.
Follow the instructions on the measuring
process in
<Object View>
.
<Signal View>
The
<Signal View>
displays the signal strength at
each measuring point without information on the
object depth.
The
<Signal View>
can be used to locate closely
adjacent
objects
and
to
better
assess
complicated material structures based on the
signal path.
Follow the instructions on the measuring
procedure in
<Object View>
.
Measuring Mode <Leakage
Detection>
In this measuring mode, the relative material
moisture of the surface is displayed. It is
therefore suitable for locating the point of
maximum material moisture and thus a possible
leakage.
Different materials on the surface, flat lying
objects and inhomogeneities in the substrate
(such as joints) can distort the result.
Measuring Mode <Distance
Measurement>
In this measuring mode, you can measure
distances on the wall. It is only possible to take
this measurement in a straight line in the
direction of travel of the wheels.
Place the detection tool onto the wall at the
starting
point
for
the
measurement.
The
reference point of the measurement is always
the top marking aid
(1)
. If necessary, press the
red start button
(16)
to delete the displayed
measured
value
and
to
start
a
new
measurement.
Move the detection tool over the wall in a
straight line in the required direction while
applying uniform pressure. The distance to the
starting point is continuously measured.
The measured value shown on the display is the
distance to the starting point for the current
measurement, not the total distance travelled
(as you move the tool back towards the starting
point, the measured value will be smaller).
If a required distance is to be marked on the
wall, mark it using the top marking aid
(1)
.
Save/transfer the measuring results
Saving Measuring Results as an Image
Measure the required range as usual. Then press
the screenshot button
(13)
.
If an SD card is inserted, the images are saved
on the card. Otherwise, the images are stored in
the internal memory of the detection tool and
can be transferred via the USB Type-C®
interface.
Data transfer via USB Type-C® interface
Do not use the provided
USB-C cable in application
higher than 5V 2A.
Using USB-C cable beyond
its rating may increase the risk of fire, personal
injury and property damage.
Open the flap for the USB Type-C® port
(4)
.
Connect the USB Type-C® port of the switched-
off detection tool to your PC via the provided
USB Type-C® cable
(21)
.
Switch on the detection tool using the on/off
button
(8)
.
Operating Instructions
Dtect200C_2610067510_01-22.qxp_D-tect200 1/18/22 1:43 PM Page 19
Содержание D-tect200C
Страница 3: ... 3 1 5 19 5 21 22 20 Dtect200C_2610067510_01 22 qxp_D tect200 1 18 22 1 43 PM Page 3 ...
Страница 4: ... 4 A 23 9 10 Dtect200C_2610067510_01 22 qxp_D tect200 1 18 22 1 43 PM Page 4 ...
Страница 5: ... 5 A A B B B x x y y Dtect200C_2610067510_01 22 qxp_D tect200 1 18 22 1 43 PM Page 5 ...
Страница 6: ... 6 C 25 24 26 27 24 Dtect200C_2610067510_01 22 qxp_D tect200 1 18 22 1 43 PM Page 6 ...
Страница 55: ... 55 Notes Remarques Notas Dtect200C_2610067510_01 22 qxp_D tect200 1 18 22 1 44 PM Page 55 ...