background image

Graphic Keypads

Installer Reference Guide

9

Bosch Security Systems     03/16    Graphic Keypads BIRG FTR1.0

Default Gateway

Only enter when not using DHCP.

MAC Address

This location is  read only and cannot be changed.  The 
MAC address of the Wi-Fi keypad is displayed here.

IP Options 

Various IP options can be configured to allow the system 
to display and or report IP related fault conditions.

Display Faults

Setting this option allows the keypad to display a 
trouble condition if the control panel detects Wi-
Fi Keypad’s IP address has changed, if there is no IP 
connection, if there is an IP lockout or an IP conflict.  

Report Network Lost

Setting this option allows the control panel to report 
when it detects that the Wi-Fi keypad can no longer 
detect a Wi-Fi signal from the local wireless access 
point.  

Report IP Conflict

This option allows the control panel to report an IP 
conflict via the dialler when it detects two computers 
on the LAN or internet have been assigned the same 
IP address. 

Report Poll Fail

This option allows the control panel to report via the 
dialler when the Wi-Fi keypad fails to send a poll to the 
base station.

Report Module Missing

This option when set allows the control panel to send 
a trouble report when the control panel detects that 
the ethernet module is missing or when the module is 
rebooting for any reason.  A restore report will be sent 
when the control panel detects that the module has 
returned to normal.

Configuration Examples

Alarm control function only.

1) Install the keypad as per instructions.
2) Set the home area for the keypad.  
3) Set keypad options as required remembering to dis-

able keypad emergency alarms and or single button 
arming if the unit is being installed externally.

4) Assign users to the area.

Access control function only.

1) Install the keypad as per instructions.
2) Set the door assignment for the keypad.
3) Set keypad options as required.
4) Set output to door to operate door.
5) Set output event assignment. 
6) Assign users to the access group.

Both Alarm and Access control functions.

1) Install the keypad as per instructions.
2) Set the home area for the keypad.  
3) Set the door assignment for the keypad.
4) Set keypad options as required remembering to dis-

able keypad emergency alarms and or single button 
arming if the unit is being installed externally.

5) Set output to access group to operate door.
6) Set output event assignment. 
7) Assign users to the area.
8) Assign users to the access group.

Box Contents

Keypads are supplied with the following parts.

Keypad Main Unit With Door
Keypad Mounting Plate
Instruction Sheet
Emergency Key Sticker

Содержание CP799B

Страница 1: ...curity System Installer Reference Guide EN Security Systems This guide covers the following keypads CP700B White CP710B Black CP722B Smart Card White CP732B Smart Card Black CP741B Wi Fi Enabled Tamper White CP799B Service Keypad ...

Страница 2: ...ADDRESS SELECT 3 INSTALLING THE KEYPAD 4 KEYPAD OPERATION 5 LCD STATUS ICONS 5 KEYPAD KEY FUNCTIONS 5 HOLD DOWN FUNCTIONS 6 KEYPAD LED INDICATORS 6 KEYPAD ALERT TONES 7 EGRESS AND LOCK CONTROL 7 WI FI KEYPAD SETUP 8 CONFIGURATION EXAMPLES 9 BOX CONTENTS 9 SERVICE KEYPAD INSTALLER TOOL 10 ADDRESSING 10 CONNECTION DIAGRAM 11 SPECIFICATIONS 11 ...

Страница 3: ...er 1 Only address 1 Table 1 Keypad Compatibility Keypad Addressing Each keypad fitted to the system must be assigned a unique address on the LAN For convenience the address dip switch configuration table shown below is also provided on the rear of the plastic keypad housing Wi Fi enabled keypads are factory set to address 1 and cannot be changed Other keypads should be set to an ad Solution Graphi...

Страница 4: ...he required keypad address at this time Step 3 If the keypad has a built in tamper switch you will also need to install the rear tamper screw in the rear tamper plate Once installed use a knife to cut the 3 small plastic tabs holding the rear tamper plate so it is no longer connected to the keypad mounting plate Step 4 To mount the keypad simply align the 4 rectangular holes in the back of the key...

Страница 5: ...ned All On or Part On On The area is turned All On or Part On Off The area is turned Off On All messages have been read Off Message queue is empty Flash An unread message is in the queue On Area is ready to turn on All On Part On Off Not ready Zone Open The Wi Fi enabled keypad or module has successfully connect ed to your local Wi Fi network The Wi Fi enabled keypad or module is not connected to ...

Страница 6: ...larm If programmed the sirens will sound and the monitoring station will be notified Table 5 Hold Down Functions Figure 7 Keypad Emergency Alarm Triggers Keypad LED Indicators Keypads includes green blue and red LED s which pro vide visual feedback during system operation The green and red LED s indicators will show area and alarm status and the blue LED will show the door status depending how the...

Страница 7: ...s nearly expired Entry Delay The hi lo entry delay warning tone will sound once every second when an en try delay zone in the area the keypad has been assigned to is triggered If the system is not disarmed before the entry time expires then an alarm will occur Error If you press an invalid button during any data entry sequence the keypad will sound a 2 second warning tone indicating that the comma...

Страница 8: ...manual SSID Scan This option will request the system to create a list of all SSID s currently in range of the Wi Fi keypad Use the down arrow key to step through the available SSID s and press OK to select the required station The SSID scan also displays the signal strength for each station in dB s Decibels To ensure reliable Wi Fi per formance do not attempt to connect the keypad the a station wi...

Страница 9: ... panel to send a trouble report when the control panel detects that the ethernet module is missing or when the module is rebooting for any reason A restore report will be sent when the control panel detects that the module has returned to normal Configuration Examples Alarm control function only 1 Install the keypad as per instructions 2 Set the home area for the keypad 3 Set keypad options as req...

Страница 10: ...panel has been placed in service mode from one of the main keypads or if the panel cabinet tamper input is unsealed Service keypad operation will cease when service mode ends or the cabinet tamper is sealed The CP799B keypad includes a built in DF smart card reader allowing RFID cards and tokens to be easily enrolled di rectly at the keypad if required Alpha text characters have also been included...

Страница 11: ... X X X ADDRESS ADDRESS ON 1 2 3 4 5 TAMPER Lock Output EGRESS INPUT N O BK RD WH BL YL GN TO DOOR LOCK 12V DF70 N O COM N C CM444 Relay Card RED BLACK WHITE BLUE YELLOW GREEN LAN LAN LAN A LAN B LOCK EGRESS Wiring Legend CM720B or CM723B Power Supply Battery backed up DOOR LOCK Egress Input ONLY USE THE SUPPLIED CONNECTION CABLE WHEN INSTALLING THE KEYPAD PROTECTION DIODE CM444B RELAY CARD MODULE ...