background image

Graphic Keypads

Installer Reference Guide

6

Bosch Security Systems    03/16    Graphic Keypads BIRG  FTR1.0

Hold Down Functions

Keypads support the following hold down function 
when they have been assigned to an area. Emergency 
key functions can be disabled if required to prevent 
nuisance alarms.  
See the Devices-Keypads & Readers-Emergency Keys 
menu option in panel programming to disable these 
features.

Hold Down Functions

Function

Meaning

All ON

Enter a valid PIN and then press and 
hold down the [ON] key, the system 
will turn on or arm all areas that the 
user belongs to at the same time.

All OFF

Enter a valid PIN and then press and 
hold down the [OFF] key, the system 
will turn off or disarm all areas that 
the user belongs to at the same time.

[4]

Press and hold down the [4] key for 
2 seconds to toggle chime mode on 
or off.

[6]

Press and hold down the [6] key for 
2 seconds to force the system to an-
swer an incoming PSTN RAS remote 
session call.

[

] + [

]

Press and hold the [

] and [

] keys 

down together for 2 seconds to trigger 
a Panic alarm. If programmed the 
sirens will sound and the monitoring 
station will be notified. 

[

] + [

]

Press and hold the [

] and [

] keys 

down together for 2 seconds to trigger 
a Fire alarm. If programmed the sirens 
will sound and the monitoring station 
will be notified.

 [

] + [

]

Press and hold the [

] and [

] keys 

down together for 2 seconds to trigger 
a  Medical alarm. If programmed the 
sirens will sound and the monitoring 
station will be notified.

Table 5: Hold Down Functions

Figure 7: Keypad Emergency Alarm Triggers

Keypad LED Indicators

Keypads includes green, blue and red LED’s which pro-
vide visual feedback during system operation.  

The green and red LED’s indicators will show area and 
alarm status and the blue LED will show the door status 
depending how the keypad has been configured.  

LED Operation For Area Control

Led

Condition

Meaning

Red

On

Area All On

Flashing

Area Alarm

Green

On

Area is OFF

Flashing

Area not ready to turn on - 
zone(s) unsealed

Red & 

Green

Both On

Area armed in Part mode 
and all zones sealed. 

Red & 

Green

Red On 

and  Green 

Flashing

Area armed in Part mode 
with zones unsealed.

Red & 

Green

Alternate 

Flashing

Keypad initialising during 
power up or LAN scan.

Red & 

Green

Flashing

Installer programming 
mode is active.

Red & 

Green

Both Off

Home Area and Access 
Group not programmed or 
keypad not powered.

Table 6: Keypad LED’s - Area Control

To have the keypad control an area on the alarm system 
you need to assign the keypad to a home area.  See the 
Devices-Keypads-Home Area menu option in panel pro-
gramming.  If alarm system control is not required then 
you should set the home area option to No Area. 

LED Function For Door Control

Led

Condition

Meaning

Blue

On

Door Locked

Blue

Fast Flash

Door Unlocked

Blue

Continuous 

Fast Flash

Door manually unlocked 
or overridden.

Blue

2 Flashes 

Door automatically 
unlocked by schedule or 
time zone

Table 7: Keypad LED‘s - Door Control

Содержание CP799B

Страница 1: ...curity System Installer Reference Guide EN Security Systems This guide covers the following keypads CP700B White CP710B Black CP722B Smart Card White CP732B Smart Card Black CP741B Wi Fi Enabled Tamper White CP799B Service Keypad ...

Страница 2: ...ADDRESS SELECT 3 INSTALLING THE KEYPAD 4 KEYPAD OPERATION 5 LCD STATUS ICONS 5 KEYPAD KEY FUNCTIONS 5 HOLD DOWN FUNCTIONS 6 KEYPAD LED INDICATORS 6 KEYPAD ALERT TONES 7 EGRESS AND LOCK CONTROL 7 WI FI KEYPAD SETUP 8 CONFIGURATION EXAMPLES 9 BOX CONTENTS 9 SERVICE KEYPAD INSTALLER TOOL 10 ADDRESSING 10 CONNECTION DIAGRAM 11 SPECIFICATIONS 11 ...

Страница 3: ...er 1 Only address 1 Table 1 Keypad Compatibility Keypad Addressing Each keypad fitted to the system must be assigned a unique address on the LAN For convenience the address dip switch configuration table shown below is also provided on the rear of the plastic keypad housing Wi Fi enabled keypads are factory set to address 1 and cannot be changed Other keypads should be set to an ad Solution Graphi...

Страница 4: ...he required keypad address at this time Step 3 If the keypad has a built in tamper switch you will also need to install the rear tamper screw in the rear tamper plate Once installed use a knife to cut the 3 small plastic tabs holding the rear tamper plate so it is no longer connected to the keypad mounting plate Step 4 To mount the keypad simply align the 4 rectangular holes in the back of the key...

Страница 5: ...ned All On or Part On On The area is turned All On or Part On Off The area is turned Off On All messages have been read Off Message queue is empty Flash An unread message is in the queue On Area is ready to turn on All On Part On Off Not ready Zone Open The Wi Fi enabled keypad or module has successfully connect ed to your local Wi Fi network The Wi Fi enabled keypad or module is not connected to ...

Страница 6: ...larm If programmed the sirens will sound and the monitoring station will be notified Table 5 Hold Down Functions Figure 7 Keypad Emergency Alarm Triggers Keypad LED Indicators Keypads includes green blue and red LED s which pro vide visual feedback during system operation The green and red LED s indicators will show area and alarm status and the blue LED will show the door status depending how the...

Страница 7: ...s nearly expired Entry Delay The hi lo entry delay warning tone will sound once every second when an en try delay zone in the area the keypad has been assigned to is triggered If the system is not disarmed before the entry time expires then an alarm will occur Error If you press an invalid button during any data entry sequence the keypad will sound a 2 second warning tone indicating that the comma...

Страница 8: ...manual SSID Scan This option will request the system to create a list of all SSID s currently in range of the Wi Fi keypad Use the down arrow key to step through the available SSID s and press OK to select the required station The SSID scan also displays the signal strength for each station in dB s Decibels To ensure reliable Wi Fi per formance do not attempt to connect the keypad the a station wi...

Страница 9: ... panel to send a trouble report when the control panel detects that the ethernet module is missing or when the module is rebooting for any reason A restore report will be sent when the control panel detects that the module has returned to normal Configuration Examples Alarm control function only 1 Install the keypad as per instructions 2 Set the home area for the keypad 3 Set keypad options as req...

Страница 10: ...panel has been placed in service mode from one of the main keypads or if the panel cabinet tamper input is unsealed Service keypad operation will cease when service mode ends or the cabinet tamper is sealed The CP799B keypad includes a built in DF smart card reader allowing RFID cards and tokens to be easily enrolled di rectly at the keypad if required Alpha text characters have also been included...

Страница 11: ... X X X ADDRESS ADDRESS ON 1 2 3 4 5 TAMPER Lock Output EGRESS INPUT N O BK RD WH BL YL GN TO DOOR LOCK 12V DF70 N O COM N C CM444 Relay Card RED BLACK WHITE BLUE YELLOW GREEN LAN LAN LAN A LAN B LOCK EGRESS Wiring Legend CM720B or CM723B Power Supply Battery backed up DOOR LOCK Egress Input ONLY USE THE SUPPLIED CONNECTION CABLE WHEN INSTALLING THE KEYPAD PROTECTION DIODE CM444B RELAY CARD MODULE ...

Страница 12: ...Bosch Security Systems Level 2 21 Solent Circuit Baulkham Hills NSW 2153 Australia Phone 1300 026 724 www boschsecurity com au 2016 Bosch Security Systems Graphic Keypads BIRG Issue FTR1 0 ...

Отзывы: