background image

CM050B

Installer Reference Guide

6

Bosch Security Systems    10/12    CP050B  FTR1.1

i

Note

  The CP050B Night Arm Station is not compatible 

with Solution 64 or Solution 16plus panels.  
Contact your distributor for more information. 

Night Arm Station Address  

Select Switch.  Each CP050B fit-

ted to the system must be set to 

a unique address via this switch.  

See Table 2. 

It is important to remember that 

each Night Arm Station added  

consumes the corresponding 

keypad address.  

This means that if you have a 

keypad set to address 2 then you 

cannot also set a Night Arm  

Station to address 2.

Figure 2: CP050B Connection Diagram

Connect to 4 wire RS485 system 

LAN.  See module connection  

specification below for more 

detail. 

Programming

Each CP050B is treated by the panel as if it were a standard keypad from the point of view of programming options.  
This means that to change parameters for a Night Arm Station which is configured for address 3 you would need to 
select Keypad 3 under the devices menu and change the required parameters..

In a multi-area system you need to set the appropriate Home Area for the Night Arm Station to control.  Each Night 
Arm Station can only control part arming for its home area.

Program any zones which are required to be isolated when armed in Part mode 1 and or Part Mode 2 before testing 
the system operation.  As a general rule Part Mode 1 zones are programmed by the installer and Part Mode 2 zones 
can be programmed by the user.

CP050B Connection Diagram

Содержание CP050B

Страница 1: ...CP050B Night Arm Station Security System Installer Reference Guide EN Security Systems ...

Страница 2: ...r a panic alarm both the PART 1 and PART 2 buttons need to be held down simultaneously for at least two seconds The system sirens and strobes will activate and can only be deactivated by entering a valid user code via the keypad A panic alarm can be activated at any time whether or not the system is already armed Operation Arming and Disarming in PART Mode 1 and 2 With the system in the disarmed s...

Страница 3: ... Arm or Disarm Part Mode 2 Press both buttons together for 2 seconds to trigger a Panic Alarm Once an alarm has been triggered you will need to enter a valid code from a keypad to cancel the alarm Status Indicators Press Button to Arm or Disarm Part Mode 1 Figure 1 CP050B Buttons and Indicators CP050B Front Panel Layout ...

Страница 4: ...ayed on the status indicators Indicator Brightness The indicator brightness can be adjusted to suit the environment or personal preference To adjust press and hold down the PART 1 button for 2 seconds Both the indicators will come on indicating that the change mode is active Now press the PART 1 key repeatedly to reduce the brightness or the PART 2 key repeatedly to increase the bright ness Once t...

Страница 5: ...list of valid module addresses and the corresponding mappings for each module Address Configuration Switch Number SW1 SW2 SW3 Night Arm Station Number Address 1 OFF OFF OFF 1 Address 2 ON OFF OFF 2 Address 3 OFF ON OFF 3 Address 4 ON ON OFF 4 Address 5 OFF OFF ON 5 Address 6 ON OFF ON 6 Address 7 OFF ON ON 7 Address 8 ON ON ON 8 Up to 8 x CP050B can be installed on the Solution 16i and Solution 14...

Страница 6: ...system LAN See module connection specification below for more detail Programming Each CP050B is treated by the panel as if it were a standard keypad from the point of view of programming options This means that to change parameters for a Night Arm Station which is configured for address 3 you would need to select Keypad 3 under the devices menu and change the required parameters In a multi area sy...

Страница 7: ...le Connection RS485 LAN Max total LAN length using multi strand security cable 300m Max total LAN length using 2 pair twisted shielded data cable Belden 8723 1200m See the control panel manual for full wiring instructions Operating Environment 0 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The CP050B can be directly installed onto a cavity or plaster wall using appropriate fixings or on...

Страница 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems CM050BIRG Issue FTR1 1 ...

Отзывы: