Conettix D6680
| Installation Instructions | 3.0 Configuration and Programming
7. On the Connect dialog box:
a. Type
9999
in the
Port
field.
3. Select
Connect
�
Remote System
.
b. Accept the values in the
Host Name
and
TermType
fields.
The Connect window appears.
4. Type the IP address of the D6680 into the
Host Name
field:
•
Use the IP address that was assigned to the
D6680 in Section 3.4 Initial Assignment of the IP
Address using ARP on page 7.
•
Type
1
in the
Port
field
•
Accept
vt100
in the
TermType
field
you are using. This is for demonstration
only.
The IP and MAC addresses used in this
example are not the same as the numbers
5. Click [
Connect]
. A
Connect failed
message
appears:
Could not open a connection to
<IP address>
.
Read steps 7c, d, and e. You must do
steps 7d and 7e quickly after step7c.
If you do not press ENTER within five sec
of seeing the message, you are
disconnected.
c. Click the
Connect
.
d. Observe the software version that appears
briefly.
e. Press the ENTER key within five sec of seeing
the message.
The program prompts you to press [ENTER] by
displaying
Press Enter to go into setup
mode.
8. If you pressed [ENTER] within five sec, you
should see the following screen (refer to Figure 11
on
page 10).
The software version shows briefly before
the [ENTER] key is pressed. Pressing
[ENTER] forces the screen to scroll and the
software version will no longer be visible.
Note the software version during the five
sec interval.
6. Click [
OK
]. The Telnet window appears again.
Select
Connect
�
Remote System
again.
Bosch Security Systems, Inc. | 5/07 | 4998138732-01
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
9