![Bosch Compress 3000 DW FOO Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/bosch/compress-3000-dw-foo/compress-3000-dw-foo_installation-instructions-manual_52814009.webp)
6 720 808 869 (2014/06)
Compress 3000 DW FOO
Appliance details | 9
3.3
Specification tables
Model
HP 270-2E 0 FOOV/S
Running ambient air temp.
°C
-7 °C/+40 °C
Outlet Water Temp.
°C
setpoint
1 °C
Minimum Inlet Water Temp.
°C
3 °C
Maximum Inlet Water Temp.
°C
70 °C
Power supply
Ph-V-Hz
1ph / 230V-240V / 50 Hz
IP rating
IP
X4
Storage size
l
270
Water heating (HP cycle)
1)
Heating capacity
kW
1.5
Max. input
kW
0.6
Max. current
A
2.6
Water heating (Full mode)
1)
Heating capacity
kW
3.15
Max. input
kW
2.25
Max. current
A
9.8
COP
2)
3.3
Unit
Dimension (D×H)
mm
705 x 1840
Packing (W×H×D)
mm
730 x 2004 x 730
Net/gross weight
kg
113/128
Sound pressure level at 2 m
dB (A)
43
Refrigerant type/Mass
kg
R134a / 0.375
Max. refrigerant circuit pressure
kPa
2700
PTR valve setting
3)
kPa
1000
Throttling type
Thermal expansion valve
System protection
High pressure limiter, Temperature limiter
Compressor
Model
WHP01900
Type
Rotary
Brand
Highly
Input
W
700
Fan motor
Model
W1G230EB
Brand
EBM Papst
Input
W
28
Speed
r/min
1500
Water connections
Water inlet
¾ BSP inch
Water outlet
¾ BSP inch
Max. water working pressure
kPa
1000
PTR valve joint
½ BSP inch
Max inlet pressure
kPa
800
Heat exchanger
Double wall plate heat exchanger
Electric heating element
Rated power input at 230 V
kW
1.65
Rated current at 230 V
A
7.2
Table 2
1) Air at 15 °C and voltage supply 230V
2) According to EN255-3 by using air at 20 °C, water inlet at 15 °C and factory settings
3) PTR valve power capacity: 10 kW