6 720 808 869 (2014/06)
Compress 3000 DW FOO
Appliance details | 7
3
Appliance details
3.1
Overview
Fig. 3
Appliance overview
3.2
Features and safety devices
Easy to operate and environmentally friendly
The heat pump has user interface with easy use menu keys for
programming. The heat pump is also environmentally friendly
as it transfers heat from the surrounding area into the water.
Heating capacity
The unit absorbs ambient energy and releases the heat into the
water stored in the tank. If the ambient temperature is low, the
heating capacity of the heat pump will be reduced, but you can
still rely on the electric element for backup: the electrical
element will automatically turn on below 0 °C to assist the heat
pump module.
Thermal Cut Out (TCOs)
The water heater is equipped with one thermal cut-out (TCO)
located near the heating element. If for any reason the water
temperature becomes excessively high, the thermal cut-out
(TCO) cuts the power circuit to the heating element. Once
activated, the TCO must be reset manually. Resetting of the
temperature limiting control must be done by a qualified
service technician.
Air inlet
Air outlet
User
interface
User
interface
cap
Tank
6720801244-03.1V
CAUTION:
The cause of the high temperature condition
must be investigated by a qualified service
technician and corrective actions must be
taken before placing the water heater in
service again.