ELECTRIC WIRING | 19
■
Explanation of main board
Table.8-2
No.
Content
1
Discharge temp. Sensor port for inverter compressor A
2
Discharge temp. Sensor port for inverter compressor B
3
Temperature of module sensor port
4
Reserve
5
Wiring port for communication between indoor and outdoor units, indoor
unit network, outdoor unit network and network accounting
6
Three-phase detection port
7
Reserve
8
Power output of transformer No.1
9
Power output of transformer No.2
10
Heat output terminal of the inverter compressor A
11
Heat output terminal of the inverter compressor B
12
Exv A driving port
13
Exv B driving port
14
Four-way valve output terminal
15
One-way valve output terminal
16
Power control output terminal
17
Null line terminal
18
Power output of transformer No.1
19
Power output of transformer No.2
20
Activation port of inverter module B
21
Port for inverter module B voltage inspection
22
Port for inverter module A voltage inspection
23
Activation port of inverter module A
24
Power supply port for main control panel
25
ON/OFF signal input port for system high pressure inspection
26
ON/OFF signal input port for system low pressure inspection
27
Reserve
28
Reserve
29
Current inspection port of the inverter compressors A and B
30
Input port for system high pressure inspection
31
Communication ports between outdoor units
32
Detection port for outdoor ambient temp. and left pipe Temp.
33
Detection port for right pipe Temp.
34
Control port of DC fan B
35
Control port of DC fan A
8.5 Electric parameters of outdoor unit
Table.8-3
System
Outdoor Unit
Power Current
Compressor
OFM
Voltage
Hz
Min.
Max.
MCA
TOCA
MFA
MSC
RLA
KW
FLA
8HP
380~415
50
342
440
18.4
20.8
25
—
17.4
0.42
3.6
—
16.5
—
15.9
10HP
380~415
50
342
440
20.6
22.1
25
—
17.4
0.42
3.6
—
16.5
—
15.9
12HP
380~415
50
342
440
21.8
22.8
25
—
17.4
0.42
3.6
—
16.5
—
15.9
14HP
380~415
50
342
440
27.9
31.8
25
—
17.4+10.5
0.71
5.9
—
16.5+10.0
—
15.9+9.6
16HP
380~415
50
342
440
33.4
32.8
25
—
17.4+10.5
0.71
5.9
—
16.5+10.0
—
15.9+9.6
Notes:
1. The current value of combination unit is the total value of each basic
model(refer to Table.8-3)
For example: 46HP=14HP+16HP*2
Power current: MCA=27.9+33.4*2=94.7
TOCA=31.8+32.8*2=97.4
MFA=35+35*2=105
Compressor: RLA=(17.4+10.5)*3
OFM:
FLA=5.9+5.9*2=17.7
2. RLA is based on the following conditions.
Indoor temp. 27°C DB/19°C WB;Outdoor temp. 35°C DB
3. TOCA means the total value of each OC set.
4. MSC means the Max. current during the starting of compressor.
5. Voltage range
Units are suitable for use on electrical systems where voltage supplied to
unit terminals is not below or above listed range limits.
6. Maximum allowable voltage variation between phase is 2%.
7. Selection wire size based on the larger value of MCA or TOCA.
8. MFA is used to select the circuit breaker and the ground fault circuit
interrupter (earth circuit breaker).
Remark:
MCA: Min. Current Amps. (A)
TOCA: Total Over-current Amps. (A)
MFA: Max. Fuse Amps. (A)
MSC: Max. Starting Amps. (A)
RLA: Rated Locked Amps. (A)
OFM: Outdoor Fan Motor.
FLA: Full Load Amps. (A)
KW: Rated Motor Output (kW)
Содержание CLIMATE 5000 VRF RDCI Series
Страница 31: ...RDCI Series All DC Inverter Outdoor Units 6 720 862 437 2016 10 31 ...
Страница 33: ......
Страница 34: ...6 720 862 437 2016 10 RDCI Series All DC Inverter Outdoor Units 34 ...
Страница 35: ...RDCI Series All DC Inverter Outdoor Units 6 720 862 437 2016 10 35 ...
Страница 36: ......