Operators Manual 

Solution Ultima Series 
(844/862/880) 

 

CC484/CC486/CC488

Содержание CC484

Страница 1: ...EN Operators Manual Solution Ultima Series 844 862 880 CC484 CC486 CC488 ...

Страница 2: ...tely disconnect this equipment should it become physically damaged and arrange for its disposal or repair The transmit level from this device is set at a fixed level and because of this there may be circumstances where the performance is less than optimal Before reporting such occurrences as faults please check the line with a standard telepermitted telephone and do not report a fault if the telep...

Страница 3: ...e Call Forward On Off 13 13 1 Telco Arm Sequence 13 13 2 Telco Disarm Sequence 14 14 Testing 14 14 1 Horn Speaker Test 14 14 2 Bell Test 14 14 3 Strobe Test 14 14 4 Walk Test Mode 14 14 5 Test Report 15 15 Event Memory 15 16 Day Alarm 15 17 Codepad Buzzer Tone Change 15 18 Remote Arming by Telephone 15 19 Partitioning 15 19 1 Master Partitioned Codepad Indicators 16 19 1 1 Zone Indicators 16 19 1 ...

Страница 4: ... SUB MA48XO 3318 Table 10 How to Arm the System in STAY Mode 1 8 Table 11 Fault Indicators 12 Table 12 Telco Arm Disarm Dialling Digits 14 Table 13 Domestic Dialling Telephone Digits 17 Table 14 Zone Status Display Descriptions 18 Table 15 System Status 18 Table 16 Glossary of Terms 20 ...

Страница 5: ...mA Current Draw in Alarm Condition 115 mA Current Draw in Alarm Condition with Codepad 105 mA Back Up Battery 6 Ah 12 VDC Rechargeable Sealed Lead Acid Battery Dimensions Case packed in carton 306 mm x 262 mm x 84 mm 12 05 in x 10 31 in x 3 31 in Weight 2 5 kg 5 51 lb Supplier Code N771 New Zealand Telepermit Solution Ultima 844 PTC 211 98 085 Solution Ultima 862 PTC 211 98 084 Solution Ultima 880...

Страница 6: ...ode 2 The STAY indicator also flashes in unison with the AWAY indicator when programming various options throughout the Operators Manual See Section 3 10 3 Arming in STAY Mode 1 for different methods of arming in STAY Mode 1 See Section 3 10 4 Arming in STAY Mode 2 for the method of arming in STAY Mode 2 Table 4 STAY Indicator Indicator Definition On System is armed in STAY Mode 1 or STAY Mode 2 O...

Страница 7: ...tive zones to be in a ready state for an intruder Remaining in the premises and only require part of the system to be in a ready state for an intruder If a zone is not sealed at the end of exit time the zone is automatically isolated and constantly displayed on the remote codepad The zone becomes an active part of the system when the zone is restored For example if a window is left open after exit...

Страница 8: ... into alarm Only your installer can program this feature Table 10 How to Arm the System in STAY Mode 1 Method One Enter your user code followed by the button for example 2580 Two beeps sound and the STAY indicator displays Exit time starts counting Any zones programmed to be automatically isolated in STAY Mode 1 flash until exit time expires At the end of exit time all zones selected to be automat...

Страница 9: ...on for example 2580 Two beeps sound 5 User Codes 5 1 Adding User Codes Only the Master Code holder can add or change other system user codes including the Master Code Up to eight user codes can be programmed to operate the system How to Add a User Code 1 Enter your four character Master Code followed by 1 and the button for example 25801 Three beeps are heard and the STAY and AWAY indicators flash...

Страница 10: ...epad Alarms 7 1 Codepad Duress Alarm A codepad duress alarm is used as a silent hold up alarm This only occurs when the number 9 is added to the end of any valid user code being used to disarm the system for example 25809 A duress alarm is only useful if your system is reporting back to a monitoring station or pocket pager Domestic reporting such as a mobile phone cannot decipher which type of ala...

Страница 11: ... system returns to the disarmed state 8 2 Code to Isolate This method restricts only those User Codes with the Code to Isolate priority level to isolate zones If any User Code has this priority level the method of standard isolating does not function How to Isolate a Zone 1 Press the button followed by your User Code and the button again to enter the Isolating Mode for example 2580 Three beeps sou...

Страница 12: ...AULT indicator to display on the codepad unless your installer programmed the automatic arming time See Section 10 Date and Time to program the date and time RF Receiver Fail The RF receiver fault registers once the system detects that the wireless receiver unit is disconnected Horn Speaker Fail This fault registers when the system detects that the horn speaker is disconnected This fault clears on...

Страница 13: ...t for example DD day of the month MM month of the year YY current year HH hour of the day MM minute of the day To program the hour of the day use the 24 00 hour format 3 Press the button to exit and return to the disarmed state Two beeps sound and the STAY and AWAY indicators turn off If a long beep sounds an error was made when entering the date and time 11 Turning Outputs On Off This feature is ...

Страница 14: ...Code followed by the 3 and keys for example 25803 Three beeps sound and the STAY and AWAY indicators flash 2 Press the 2 key followed by the key to select the Telco Disarm Sequence Three beeps sound 3 Enter the Call Forward Disable Sequence for example 61 to disable the No Answer Call Forward sequence or 21 to disable the Call Forward Immediate Sequence To program a in the Telco Disarm Sequence en...

Страница 15: ...r to beep during the disarmed state when activated How to Turn Day Alarm Off Hold down the 4 key until two beeps sound Day alarm turns off 17 Codepad Buzzer Tone Change Hold down the 8 key to continuously change the tone of the codepad buzzer There are 50 different tones from 1500 Hz to 5000 Hz If multiple codepads are installed each codepad can have a different tone 18 Remote Arming by Telephone ...

Страница 16: ...ged If the FAULT indicator is not illuminated the system has no faults PARTIAL Indicator Only displays when an area is armed in STAY Mode 1 For example if the PARTIAL indicator is displayed an area is armed in STAY Mode 1 If the PARTIAL indicator is not displayed no areas are armed in STAY Mode 1 19 2 Operation of Codepads in Partitioning Area Addressable Codepad Operations If you have a system pa...

Страница 17: ...ephone number to program press 4 This inserts a break between the first telephone number and the second telephone number If there is only one telephone number to program press the key to exit this function 4 Enter all the digits of the second telephone number for example 96721055 As each digit is entered the corresponding codepad indicators display 5 After the last digit of the second telephone nu...

Страница 18: ...e system status information is divided into four digits Table 15 System Status System Status Display Description First digit Indicates whether the system is armed or disarmed 8 Disarmed 9 Armed Second digit Indicates which codepad alarm was triggered by the operator 0 No Codepad Alarm 1 Codepad Panic or Duress Alarm 2 Codepad Fire Alarm 3 Codepad Medical Alarm Third digit Indicates when the AC mai...

Страница 19: ...CC484 CC486 CC488 Operators Manual 21 Basic Pager Reporting EN 19 Bosch Security Systems 3 04 SUB MA48XO 3318 Figure 7 Basic Pager Display 1 2 3 1 Subscriber ID number 2 Zone status 3 System status ...

Страница 20: ...zones programmed for 24 hour operation Dynamic Battery Testing Use to monitor and test the condition of your back up battery Entry Time Entry Delay Time allowed after entering your premises by a zone programmed for delayed operation so you can disarm the system External Equipment Any device connected to your system such as detectors codepads and sirens Forced Arming Permits your alarm system to be...

Страница 21: ...tomatically in STAY Mode 1 STAY Mode 2 Automatically isolates zones when your system is armed in STAY Mode 2 Only the Master Code holder can program zones to be isolated automatically in STAY Mode 2 Telco Arm Sequence Automatically calls the telephone exchange and diverts your telephone number to another telephone when the system is armed in AWAY mode In Australia this feature is called Call Forwa...

Страница 22: ...23 Installation Notes EN 22 Bosch Security Systems 3 04 SUB MA48XO 3318 23 Installation Notes Installation Company Technician s Name Technician s Telephone Number Installation Date Warranty Expiration Panel Software Version Service Notes ...

Страница 23: ...ically isolated in STAY Mode 1 or was programmed for day alarm operation Isolated In STAY Mode 1 Day Alarm Enabled Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 User Code Names Master Code Default 2580 User Code 1 Y User Code 9 User Code 2 User Code 10 User Code 3 User Code 11 User Code 4 User Code 12 User Code 5 User Code 13 User Code 6 User Code 14 User Code 7 User Code 15 User Code 8 ...

Страница 24: ...ng YES NO Remote Arming by Telephone YES NO Automatic Arming Time AM PM Automatic Disarming Time AM PM Output Descriptions Output 1 Output 3 Output 2 Output 4 Isolating Method Standard Isolating YES NO Code to Isolate YES NO Communication Options Back to Base Reporting YES NO Domestic Reporting YES NO Domestic Reporting Number of Beeps Other System Information Siren Run Time Minutes Can your syste...

Страница 25: ... ID Number 12 Radio User code 12 ID Number 16 Radio User code 16 ID Number 9 Digit RF Device ID Numbers Place the RF Device ID Sticker in the appropriate location below Zone Number Zone Number 1 RF Device 1 ID Number 9 RF Device 9 ID Number 2 RF Device 2 ID Number 10 RF Device 10 ID Number 3 RF Device 3 ID Number 11 RF Device 11 ID Number 4 RF Device 4 ID Number 12 RF Device 12 ID Number 5 RF Devi...

Страница 26: ...Indicator 6 MAINS Indicator 5 Off Indicator 5 On Indicator 5 STAY Indicator 5 System Disarmed 5 Zone Indicators 5 Communciation Fail 12 D Date and Time 12 Day Alarm 14 Deleting Radio User Codes 8 Deleting User Codes 8 Detectors 19 Disarmed 19 Disarming 8 Domestic Dialling 16 Acknowledging Domestic Calls 16 Disable 17 Programming Domestic Telephone Numbers16 Duress Alarm 10 E E2 Fault 12 Entry Dela...

Страница 27: ...al Indicator 16 Partitioning Area Addressable Codepad 16 Area Display Indicator 15 Area On Off Indicator 15 Codepad Operations 16 Zone Indicators 15 R Radio User Codes Adding 8 Deleting 8 Remote Arming 15 Remote Control 19 RF Low Battery 12 RF Receiver Fail 12 RF Sensor Watch 12 S Sealed 19 Sensor Watch 12 20 Silent Alarm 20 Specifications 4 STAY Indicator 5 STAY Mode 1 7 20 Entry Guard Timer 7 ST...

Страница 28: ... 2003 Bosch Security Systems SUB MA48XO 3318 Issue 1 12 4998152245B Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 7171 ...