Online Measurement and Calibration | 13
Bosch Motorsport
Manual_C_80
81 / 144
Check box to enable online
offset calibration and enter
desired physical target value
In the channel view
Activate switch
to enable online
calibration
13.2.2 Performing the online offset calibration
C 80 has to be connected to RaceCon to calibrate the sensor’s offset.
1.
Apply the desired physical condition to the sensor (e.g. 1 G to an acceleration sensor).
2.
Open the measurement channel’s online page by double-clicking on the measure-
ment channel name in the Data Area.
3.
Enter the physical target value (e.g. 1 G) and press the ‘Calibrate’ button.
Calibration
target value
Initiate
calibration
The sensor’s offset is now calibrated.
Содержание C 80
Страница 1: ...Data Logger and Sensor Interface C 80 Manual Version 1 0 04 08 2021 ...
Страница 11: ...Mechanical Drawing 5 Bosch Motorsport Manual_C_80 11 144 5 Mechanical Drawing ...
Страница 30: ...8 First Steps 30 144 Manual_C_80 Bosch Motorsport ...
Страница 141: ...Bosch Motorsport Manual_C_80 141 144 ...
Страница 142: ...142 144 Manual_C_80 Bosch Motorsport ...
Страница 143: ...Bosch Motorsport Manual_C_80 143 144 ...
Страница 144: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt www bosch motorsport com ...