12 | Analog and Frequency Inputs
68 / 144
Manual_C_80
Bosch Motorsport
– C 80 filters have constant, frequency independent delay
– Delay (e.g. 22 samples at 10 ms) is corrected during recording
– No delay filtered vs. unfiltered in recorded data
– Correction is (of course) not possible for real time data (display, online, PWM out)
– Use filtered data for recording, use unfiltered data for real-time
12.2.6 Configuring a frequency input
Example: measurement of wheel speed
– Pulse wheel attached to wheel
– Each passing tooth of pulse wheel triggers hall sensor
– Calculation of wheel speed with wheel circumference
1.
Click on ‘Measurement Sources’ in the Toolbox.
2.
To expand the list of ‘I/O Channels’, click on the ‘+’ in the C 80 Project Tree.
3.
Drag the ‘Velocity’ digital signal source from the Toolbox and drop it on the desired
‘REV’ input channel in the C 80 Project Tree.
Drag + Drop
The ‘Velocity Wizard’ opens.
4.
Select the sensor type. The C 80 works with Halleffect and DF11 sensors.
Содержание C 80
Страница 1: ...Data Logger and Sensor Interface C 80 Manual Version 1 0 04 08 2021 ...
Страница 11: ...Mechanical Drawing 5 Bosch Motorsport Manual_C_80 11 144 5 Mechanical Drawing ...
Страница 30: ...8 First Steps 30 144 Manual_C_80 Bosch Motorsport ...
Страница 141: ...Bosch Motorsport Manual_C_80 141 144 ...
Страница 142: ...142 144 Manual_C_80 Bosch Motorsport ...
Страница 143: ...Bosch Motorsport Manual_C_80 143 144 ...
Страница 144: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt www bosch motorsport com ...