INSTALLATION
– STORAGE TANK
COMPLIANCE WITH STANDARDS
The installation must be performed by an Authorised Persons and comply with the
requirements of AS/NZS 3500.4, AS/NZS 3000 in New Zealand NZBC G12 and all local codes
and regulatory authority requirements. It is recommended the solar storage tank be installed
at ground or floor level. The water heater must stand vertically upright.
SUITABILITY FOR INSTALLATION IN FROST AREAS
The system is suitable for installation in areas that experience sub-zero temperatures; it has
an air bleed valve freeze protection system integrated into the system to prevent damage in
the event of a light frost. Areas of known heavy frost or altitudes higher than 600 m above sea
level are not suitable for this system. The minimum temperature these systems are suitable for
in no lower than -5°C.
NOTE: THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING.
LOCATION
Whether located outdoor or indoor, the solar water storage tank should be installed close to
the most frequently used hot water outlet (typically the shower) and its position chosen with
safety and service in mind. The panels should be located as close as possible to the storage
tank.
CLEARANCES
Allow adequate room to work with tools. A minimum of 250mm clearance around the water
heater is required. An additional 300mm is required for relief valve removal, 800mm for access
cover removal and 400mm for element removal. You should be able to read the information on
the rating plate and all informative labelling.