118
_58300000145664_ARA_EN_D.doc
– 20.09.13
Seite 11 von 12
7.3
Overheating protection is missing
7.3.1
Affected appliances
BSG82422/17
BSG82422/21
BSG82425/17
BSG82425/18
BSG82425N/18
BSG82433/17
BSG82480/17
BSG82480AU/17 BSG82502/17
BSG82503/17
BSG82515/17
7.3.2
Symtom
Electronics module does not contain overheating protection and
overheating protection mount.
7.3.3
Solution
The overheating protection is not missing!
Overheating protection has been omitted and is no longer required
due to engineering changes. Overheating protection is also no longer
described in the user’s manual.
7.4
Sealing of dustbox is not in correct position
7.4.1
Affected appliances
All “bag & bagless” appliances with dustbox 670676.
7.4.2
Symptom
Sealing at the inlet of the dustbox is not in the correct position and
does not seal properly.
7.4.3
Solution
Mount sealing with glue (suitable for rubber and plastic) on the
dustbox.