58300000187895 ARA EN A
MAY 2015
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Page 35 of 36
Copyright by BSH Home Appliances Corporation
1901 Main St
▪ Suite 600 ▪ Irvine, CA 92614
800 944-2904
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
Always confirm that the range and all components are functioning
normally after setting the option code.
10.2.3 Displaying Error Memory
1. Follow the steps in the
Accessing Service Mode
section.
2. Advance through the menu until
Error Memory
is visible
3. Press (1) to show the error list; if no errors are logged,
nonE
will be visible in the display.
Errors are displayed in numeric order; the error code (Exxx)
will appear on the left and the error count will appear on the
right of the display. (Example:
E206: 003
indicates that error
code 0206 has been logged three times.)
4. Press (1) or (0) to cycle through the error memory list.
5. Press
Enter
to return to the initial Error Memory screen and
Enter
again to advance to the next menu option.
10.2.4 Testing Relays
Refer to the table in the
Accessing Service Mode
section for a list of
relay test menu options.
1. Follow the steps in the
Accessing Service Mode
section.
2. Advance through the menu until
Relay Tests
appears in the
display.
3. Press (
1
) to begin testing.
4. Press
Enter
to navigate through the relay options.
The initial displayed state will reflect the current state of the
relay.
5. Press (
1
) or (
2
) to change the state of the relay.
6. After navigating through all relay tests, press
Enter,
then
Enter
again to advance to the next menu option.
10.2.5 Testing Front Panel
The Front Panel Key Test will confirm that all control inputs are
connected and operating.
The tests are based on the Option Code
that was set before entering Service Mode
.
1. Follow the steps in the
Accessing Service Mode
section.
2. Advance through the menu until
Key Test
appears in the
display.
3. Press (
1
) to begin testing..
4. When the test is successfully completed,
Key Test
appears in
the display again. Press
Enter,
then
Enter
again to advance to
the next menu option
To exit the test, it must either be successfully completed
or the power must be reset.
10.3 Wiring Diagrams and Schematics
The wire color key (Table 10) and element strip diagrams are shown
below. For schematics, please refer to the
Slide-in Range Service
Guide,
which can be found on
QuickFinder
or attached to the vented
housing panel in the rear of the range.
Wire Color Key
BK
Black
BN
Brown
BU
Blue
GN
Green
GR
Gray
OR
Orange
RD
Red
VT
Violet
WH
White
YE
Yellow
BN/WH
Brown/White
BU/WH
Blue/White
OR/BK
Orange/Black
VT/WH
Violet/White
YE/BK
Yellow/Black
Table 10 Wire color key