20
Installation Instructions
1. Disconnect electrical power to the water heater.
2. Remove the front cover of the water heater (4 screws).
3. Connect main controller RCM3211 with appliance.
4. Confirm "WATER TEMPERATURE ADJUSTMENT CONNECTOR" is not connected.
5. Reconnect electrical power to the water heater.
6. Press the [
] or [
] button on the remote controller prior to switching on the controller.
Changes must be made within 10 minutes of the power being supplied to the unit . If the display
does not switch to setting mode despite pressing the [
] or [
] buttons, unplug the power and
repeat the above procedure.
7. The item number and data are shown as well as "Maintenance". (Initial setting for the item number
is "99".)
8. When the [
] button is pressed, the "99" displayed will chenge to 10, 11, ...., 1F, 20, 21, etc..., and
conversely when the [
] button is pressed, the "99" displayed will change to 10, FF, FE, FD, FC,
27, etc....
9. 11 and 12 are set as per procedure 7. When the setup switch is pressed, "ON" or "OFF" blink.
Modification procedure of temperature setting to 40
°
C, 60
°
C, and 65
°
C.
(40
°
C in case of BC3200RA5)
10. Press [
] button to switch between ON and OFF.
Note: The setting changes can be cancelled by pressing the Power On/Off button before confirm-
ing the settings, or if the unit is left alone for ten minutes without confirming the settings. If
the default setting needs to be changed again, disconnect the electrical power to the unit,
reconnect it and follow this procedure again.
11. Once setup is complete, press the [
] and [
] buttons simultaneously for at least five seconds
while the item number is blinking. Once completed, a buzzer sounds. (The modified setup will not
be recorded unless this step is performed.)
* Factory Default Setting
BC3200RA
55
°
C
60
°
C
65
°
C
40
°
C
BC3200RA5
50
°
C
40
°
C
40
°
C
40
°
C
11
OFF
ON
OFF
ON
12
OFF
OFF
ON
ON