8
Installation dimensions
Single installation
Legend:
A
Area for installation of the water connection
It is recommended the water-box be placed adjacent to
the installation cavity, so that it can be accessed for
service without uninstalling the appliance. If this is not
possible, place the recessed water box adjacent to the
power supply socket elevated at the heights as
referenced in areas A+B.
B
Area for installation of the power connection
C
Opening depth of niche, depending on kitchen design
C = 24" (610 mm) minimum
NOTE:
Cavity must be square. Side wall of the cavity must be flush.
Appliance
X
Y
18" (17
3
/
4
" / 450,8 mm)
18" (457 mm)
9" (229 mm)
24" (23
3
/
4
" / 603,2 mm)
24" (610 mm)
12" (305 mm)
30" (29
3
/
4
" / 755,6 mm)
30" (762 mm)
15" (381 mm)
IMPORTANT !
It is strongly recommended the top panel boundary of the
niche be of solid material (
5
/
8
" thickness). Make sure that
the upper boundary is completely flush for a depth of at
least 4".
IMPORTANT !
Make sure that the side walls of the niche are completely
flush ! If, for some reasons, a seperate niche cabinet is
created, make sure that the furniture return area is at least
4" deep.