Product information
|
39
6720817513 (2021/09)
BH/B/B...M/B...ER/BS...ER/BH...ERZ/BHS...ERZ
2.2
Scope of delivery
500 litre cylinder
• Storage cylinder made of PU rigid foam
• Thermal insulation:
– ErP "B": additional thermal insulation, 40 mm
– ErP "C": foil jacket on flexible foam underlayer
• Casing lid
• Upper insulation
• Technical documents
750...1300 litre cylinder
• Storage cylinder
• PU rigid foam halves
• Thermal insulation:
– ErP "B": polystyrene jacket, packaged separately
– ErP "C": foil jacket on flexible foam underlayer
• Casing lid
• Upper insulation
• Floor insulation
• Bag of small parts
– Fleece strip
– Fleece circular blank
– Compass and plug
• Technical documents
2.3
Determined use
These buffer cylinders may only be filled with heating water and used in
sealed heating systems.
The buffer cylinders can be used for indirect potable water heating via a
freshwater station.
Only fill solar heat exchangers with propylene glycol/water mixtures
(heat transfer medium L or LS). The use of any other heat transfer
medium is not permitted.
2.4
Specifications
• Technical data (
Fig. 1, page 58 and Fig. 2, page 59).
• Pressure drop diagram for solar heat exchanger (
2.4.1
Permitted maximum values
2.4.2
Data plate
The data plate is located on the left, next to the connections
(
Unit
BH...
B...
B...M
B...
BH...
ERZ
BS...ER
BHS...
ERZ
BH...
PN6
Operating pressure for the
water
bar
3
3
3
6
Operating pressure
solar heat exchanger
bar
–
–
10
–
Operating temperature
heating water
°C
95
95
95
95
Operating temperature
solar heat exchanger
°C
–
–
130
–
Maximum recommended flow
rate through connector 1 1/2"
m
3
/h
approx.
5
approx.
5
approx.
5
approx.
5
Temperature-dependent feed
flow rate:
Maximum 5 m
3
/h, function
successfully tested up to:
m
3
/h
–
1.5
1.5
–
Table 3 Permitted maximum values
Position Description
1
Model designation
2
Serial number
3
Actual capacity
6
Year of manufacture
9
Maximum flow temperature, heat source
10
Maximum flow temperature, solar
17
Maximum operating pressure, heat source side
18
Maximum operating pressure, solar side
Table 4 Information on the data plate
Содержание B 1000-6 ER
Страница 63: ...Andmekaitsedeklaratsioon 63 6720817513 2021 09 BH B B M B ER BS ER BH ERZ BHS ERZ 9 10 11 ...
Страница 66: ...66 Andmekaitsedeklaratsioon BH B B M B ER BS ER BH ERZ BHS ERZ 6720817513 2021 09 20 21 22 ...
Страница 67: ...Andmekaitsedeklaratsioon 67 6720817513 2021 09 BH B B M B ER BS ER BH ERZ BHS ERZ 23 6 720 806 606 13 1ITL ...
Страница 75: ......
Страница 76: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...