Connecting Alarms (inputs 1 through 2)
You can configure alarms 1 through 2 as Normally Open (N.O.)
or Normally Closed (N.C.) alarms.
9.2.1
Connecting a Normally Open Alarm
1.
Connect the alarm to the appropriate input (1 through 2)
and ground at the AutoDome Junior.
Figure 9.2
N.O. - Normally Open
2.
From the AutoDome Junior HD Settings page select
Interface>Alarm Inputs. Refer to
Section 12 Configuring the
AutoDome Junior HD, page 108
, for directions about
accessing the Settings page.
Ref. # User Contact Dome
Color
1
Normally
Open
Alarm In 1 or Alarm In 2
(Ref. #3)
Brown IN 1 or
Orange IN 2
2
Common
Ground (Ref. #4)
Green
AutoDome Junior Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm