AUTODOME IP starlight 5100i
Alarm | en
61
Bosch Security Systems
User Manual
2020-11 | draft 0.9 |
The table below identifies the Input and Output options and the additional fields that appear
depending on the options selected.
Field
Value
Additional Input
field
Additional
Output field
NOTES
Input
Alarm input
Day/night
IVA/
Connection
Time
Time range
1: Input 1
2: Input 2
00:00
00:00 00:00
Output 1 /
Output 2
None
Alarm output
AUX on / AUX off
Pre-position
1: Output 1
1: Scan 360°
7: Custom tour
8:
Pre-position
tour
18: Auto pivot
57: Night mode
60: On-screen
display
67: IR focus
correction
80: Digital zoom
Scene 1
Scene 2
Not available as an
Output if Input is
“Time range”.
Click the checkbox
Enabled
to activate the alarm.
Click Set to save. The camera’s system activates the alarm rules.