3.7.1
Wiring for Multiple AutoDomes
To wire multiple AutoDomes in a series, or “daisy chaining,” you must apply a terminating
resistor to the last dome of the series. The Interface Board is supplied with a 100 Ω
terminating resistor located between the Biphase terminals C- and C+ (pins 1 and 2) of the
P105 control connector (see item 5 in
Figure 3.11
above). Remove the resistor from all but the
last AutoDome Interface Board. The maximum number of AutoDomes that can be daisy
chained is four (4).
If using the RS485 protocol for control, switch the terminating resistor from the Biphase C+
and C- terminals to the RxD+ and TxD- terminals (pins 4 and 5) of the P105 control connector
for the last dome (refer to item 6 in
Figure 3.11
above).
3.7.2
Connecting Wires to the Pipe Interface Board
The Pipe Interface Board contains all of the connectors for control, data, image, and power
wires. Follow the procedures below to make the proper connections.
1.
Attach a BNC connector to the incoming video coax cable. Connect the incoming coax
cable to the BNC jack (female connector enclosed by the plastic cover) on the coax cable
with ferrite. Slide the plastic cover over the connection. Refer to
Section 3.4.1 Coaxial
Cable Connections, page 41
.
2.
Connect the BNC plug (male connector) of the coaxial cable with ferrite to its mating
connector J102 on the Pipe Interface Board.
Ref. Description
Connector
Wire Gauge
Pin
Description
1
Pipe Interface Module
2
Video Coax In
J102
3
6-pin Connector Alarms In (3-7)
P103
4
4-pin Connector Alarms Out (1-3)
P102
5
100 Ω Resistor
P105
6
Data In/Out
P105
AWG 26-16
1
Biphase (C-)
2
Biphase (C+)
3
Earth Ground
4
RxD +
5
TxD -
6
Signal Ground
7
Alarms In (EOLR Supervised, 1-2)
P104
AWG 26-16
7
Ground
6
Alarm 2
5
Alarm 1
4
Earth Ground
8
Relay Output
P104
AWG 26-16
3
Normally Closed
2
Common
1
Normally Open
9
Dome Power
P101
AWG 18-14
3
Dome 24 VAC
2
Earth Ground
1
Dome 24 VAC
10
Heater Power
P107
AWG 18-14
2
Heater 24 VAC
1
Heater 24 VAC
11
RJ45 Ethernet or UTP Video
(Ethernet for VG5 700 Series only)
J101
12
To AutoDome
WARNING!
Use a 24 VAC Class 2 power supply only.