background image

Bosch Security Systems

User Manual

2012.11

960H Day/Night IR Bullet Camera

Installation | en       

9

6

Installation

6.2 Monitor connection

6.3 Camera adjustment

CAUTION!

To prevent humidity problems, the camera must be installed in dry conditions. 

The housing front should never be removed in wet or moist conditions. Doing 

so could cause condensation on the inside of the camera window.

1.

2.

3.

4.

5.

6.

7.

Remove the housing front.

Connect service monitor. (optional)

Adjust zoom and focus.

Fasten the zoom and focus lever.

Adjust OSD settings. (refer to OSD section)

Disconnect service monitor cable. (optional)

Re-mount housing front. Include warning to (1) check rubber seal is in place. And (2) tighten 

housing front firmly to ensure protection against water ingress. 

DU

AL(DC12V/A

C24V) 

R

egulat

ed P

ow

er Suppl

y

DU

AL

(DC12V/A

C24V)

Terminal block 

Terminal block connector

Female 

BNC connector

*Sold separately

Video In

TV Monitor

Screw

Terminal

"+","-" Indication

2.6x3.2

(0.1x0.12)

10.16

(0.4)

5.08(0.2)

15.4(0.6)

18.2(0.71)

Camera

mm

(in.)

Ground contact

Signal contact

Housing front fastened enough.

(No gap between housing front and housing body)

Protection against water ingress ensured.

Housing front not fastened enough.

(Gap between housing front and housing body)

Risk of water ingress.

V

X

Содержание AN traffic 4000 IR

Страница 1: ...AN bullet 4000 IR 960H Day Night IR Bullet Camera ...

Страница 2: ...s 960H Day Night IR Bullet Camera Table of Contents 1 Cautions 2 Important safety instruction 3 Features 4 Components 5 Camera parts 6 Installation 6 1 Mounting position 6 2 Monitor connection 6 3 Camera adjustment 7 OSD menu structure 8 Specification 8 1 Dimensions ...

Страница 3: ... domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CAUTION Any changes or modifications in construction of this devies which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment CAUTION 1 A regulated DC12V 1A power supply is recommended for use with t...

Страница 4: ...ntally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract Household users should contact either the retailer where they for disposal CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICING TO QUALIFED SERVICE PERSONNEL This symbol is intended to alert t...

Страница 5: ...ded for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket o...

Страница 6: ...esolution Integrated IR LED s for discrete surveillance in dark environments Multi language On Screen Display OSD with joystick control 2DNR 4 Privacy Zones Motion Detection ATR Adaptive Tone curve Reproduction Digital WDR Cable managed bracket for secure and clean installation Vandal resistant IK08 Outdoor rated IP66 4 Components Qty Description 1 VTI 4075 V9x1 C camera with integrated mounting b...

Страница 7: ...Day Night IR Bullet Camera Camera parts en 7 5 Camera parts 1 2 3 4 5 6 7 8 Sunshield Fixing Bolt Sunshield Mounting Bracket Housing Body Housing Front Photo cell Lens High Power LED FAR WIDE TELE NEAR OSD joystick Service cable connector Rubber seal ...

Страница 8: ...w the highlight Prolonged exposure to bright lights may cause bleaching of the sensor s color filters This will be visible as colored spots in the picture and is irreversible WARNING The mounting surface mounting screws plugs and junction box must be stable and capable of supporting a maximum load of 4 kg 8 82 pounds Mounting to an improper surface or using improper mounting material can cause cam...

Страница 9: ...ings refer to OSD section Disconnect service monitor cable optional Re mount housing front Include warning to 1 check rubber seal is in place And 2 tighten housing front firmly to ensure protection against water ingress DUAL DC12V AC24V Regulated Power Supply DUAL DC12V AC24V Terminal block Terminal block connector Female BNC connector Sold separately Video In TV Monitor Screw Terminal Indication ...

Страница 10: ...NTSC 1 100 NTSC 1 250 1 500 1 1000 1 2000 1 4000 1 10000 AGC 6 12 18 24 30 36 42 44 8 RETURN SHUT IRIS Both the Shutter and the Mechanical Iris are automatically adjusted according to brightness Auto Iirs Default The Shutter stays at the manually selected value and only the Mechanical Iris adjusts brightness MAIN MENU 1st Sub 2nd Sub 3rd Sub 4th Sub WHITE BAL ATW SPEED 000 255 DELAY CNT 000 255 AT...

Страница 11: ...OW MID MIDHIGH HIGH RETURN ATR Adaptive Tone Curve Reproduction The function provides gradation compensation to improve the contrast of subjects both low luminace areas and high luminance areas exist in the same picture MAIN MENU 1st Sub 2nd Sub 3rd Sub 4th Sub MOTION DET ON DETECT SENS 000 127 BLOCK DISP OFF ON ENABLE CONTROLER MONITOR AREA ON OFF AREA SEL 1 4 2 4 3 4 4 4 TOP NTSC 000 244 PAL 000...

Страница 12: ...FF ON DELAY CNT 0 255 DAY NIGHT 0 255 NIGHT DAY 0 255 RETURN COLOR BW BURST OFF ON IR OPTIMIZER OFF ON MODE AUTO CENTER LEVEL 0 31 RETURN EXT1 EXT2 IR Optimizer If when the night operation mode of the DAY NIGHT function is established the mode is used together with an external infrared LED light source excessive front lighting may occur resulting in overexposure The IR Optimizer function makes it ...

Страница 13: ...ODE RETURN LANGUAGE ENGLISH 日本語 DEUTSCH FRANCAIS Русский PORTUGUÊS ESPAÑOL 中文 CAMERA RESET BACK EXIT SAVE ALL Important Note Any changes made to the camera settings must be saved prior to exiting the OSD menu Otherwise all changes will be discarded By changing the lens option in the OSD from MANUAL to AUTO will automatically change the SHUTTER AGC setting from AUTO IRIS to SHUT AUTO IRIS Default A...

Страница 14: ... White Balance ATW PUSH USER1 USER2 ANTI CR MANUAL PUSH LOCK 2DNR On Off Level Adjustable ATR On Off Level Adjustable Function MIRROR BRIGHTNESS CONTRAST SHARPNESS HUE GAIN Motion Detection Zone 4ea Privacy Masking Zone 4ea Language English Japanese German French Russian Portuguese Spanish Simplified Chinese Day Night True Day Night with ICR Mechanism OSD Built in OSD Control Internal IR LED m ft ...

Страница 15: ...Bosch Security Systems User Manual 2012 11 960H Day Night IR Bullet Camera Dimensions en 15 8 1 Dimensions Ø70 2 75 148 5 82 120 4 72 Approx 257 10 1 60 2 36 mm in 126 4 96 Ø80 3 14 2EA 3 Ø6 0 0 23 ...

Страница 16: ...博世安防系统 使用手册 2012 11 16 简体中文版 目录 室外日 夜子弹型摄像机 目录 1 注意事项 2 重要安全指示 3 特性 4 组件 5 摄像机零件 6 安装 6 1 装配位置 6 2 连接监视器 6 3 摄像机调整 7 屏幕显示选单结构 8 规格 8 1 尺寸 ...

Страница 17: ...操作 指南安装时 可能会对无线电通信产生有害干扰 在住宅区操作本装备时 可能造成有害干扰 此时 用户需自费矫正此干扰 警告 此为A类产品 在家用环境下 此产品可能引发无线电干扰 在此情况 下 用户需采取适当措施 注意 装备的结构未经负责合规性的相关方明确许可的变更或修改 都可能致 使用户失去操作本装备的权利 注意 1 为了获得最佳图像且保持稳定操作 此摄像机建议采用稳压的12V 1A直流电源 非稳压的供应电源可能造成摄像机受损 采用非稳压电源供应时 产品将不在保固范围内 2 建议应将此摄像机 与拥有CCTV品质75视频阻抗等级的监视器一起使用 当监视器切换为高阻抗时 请相应调整 3 请勿尝试拆解摄像机以接近内部组件 保修请洽询您的经销商 4 请勿将摄像机直接朝向日光或任何强光或反射光线 以免图像模糊且可能致 使CCD 电荷耦合组件 受损 5 请勿拆除保固服务的序号标签 6 请勿让摄像机曝露...

Страница 18: ... 对环境或人类健康产生可能的 伤害 请与其它类型废弃物分开并回收 让材料资源可持续再利用 本产品不可与其它商业垃圾混合 有关环保回收项目的地点与方法的详 细信息 请向购买处所或您当地的政府办事处洽询 企业用户应与其供货商联系 并确认其购买合同条款与条件 家庭用户应向零售商洽询其处置方式 注 意 触电危险请勿开启 注意 为了降低触电风险 用户请勿拆除外盖 或背盖 请交由合格的 服务人员进行保修 为了降低触电风险 用户请勿拆除外盖 或背盖 请交由合格的 服务人员进行保修 此符号是在提醒使用者 随附于装置的文件中 有重要的操作与 保养 服务 指南 注意 这些保修指南 仅供合格的服务人员使用 为了降低触电风险 除非您 具备资格 否则请勿执行任何操作指南所述以外的保修 仅能采用等级2的电源供应 ...

Страница 19: ...设备 含放大器 的任何热源附近 9 请勿破坏有安全作用的极化或接地型插头 极化插头有两个金属 片 其中一片比另一片为宽 接地型插头则有两个插片和第三支用 来接地的插脚 宽的金属片或第三支插脚 都是为了您的安全 若 所提供的插头不适用于您的插座时 请洽询合格电工更换老式插 座 10 保护电源线免被踩踏或挤压 特别是靠近插头 便捷插座及离开该 装置的地方 11 仅能采用制造商所指定的附件或配件 12 仅能采用制造商所指定或随设备出售的推车 支架 三脚架 托架 或桌子 使用推车时 移动推车 设备的组合时要特别小心 以免 翻倒受伤 13 闪电暴风雨或是长期未使用 请将装置插头拔除 14 所有保修应交由合格的服务人员来进行 当设备已因任何方式损坏 时 都需要维修 如电源线或插头损坏 液体溅入或有异物掉入设 备中 设备曾曝露于雨中或潮湿环境中 操作不正常或曾被摔落 等 ...

Страница 20: ...H 1 3 感应器 拥有真实日 夜滤镜 可提供各种照明条件下最佳性能的9 22mm镜头 720电视线的水平感应器分辨率 整合式红外 LED 以供黑暗环境下间断监测 附摇杆控制的多国语言屏幕显示 OSD 2DNR 4个隐私区域 动域检测 ATR 自适应色阶再现 数字WDR 电缆管理托架 以利安全与整齐的装设 防破坏 IK08 室外级 IP66 4 组件 数量 说明 1 VTI 4075 V9x1 C 含整合式装配托架的摄像机 1 视频输出 测试缆线 3 螺丝 PH 1 SUS 5x30 1 扳手 M6六角 1 导引样式板 1 使用手册 本手册 ...

Страница 21: ...博世安防系统 使用手册 2012 11 室外日 夜子弹型摄像机 摄像机零件 简体中文版 21 5 摄像机零件 1 2 3 4 5 6 7 8 遮阳罩固定螺栓 遮阳罩 装配托架 外罩本体 外罩前端 拍照单元 镜头 高功率LED OSD摇杆 保修缆线接头 橡胶密封垫 宽 望远 远 近 ...

Страница 22: ...获得最佳效果 不论操作或非操作状态下 都不要将它曝露在日光或聚光灯直射处 避免摄像机视野中有强光 强光将造成 拖影 会在强光上方与下方形成白色线 长期暴露在明亮的光线中 可能导致感应器彩色滤光片白化的情形 这样会在图片中 形成彩色斑点 且无法消除 警告 装配面 装配螺丝 插头及接线盒等均需稳固 且最高能支撑4公斤 8 82磅 的负荷 装配在不适当的表面 或使用不当的装配材料时 可能造成摄像机故障 且也潜在安 全危险 注意 确认装设摄像机表面采用适当的装配螺丝与膨胀管 随附的通用安装螺丝可供大多数 塑料膨胀管使用 请在安装摄像机前确认其兼容性 警告 为避免潮湿问题 摄像机应安装在干燥环境下 当完成连接后 应将电缆导线密封 360 90 360 第1个转轴 第2个转轴 第3个转轴 ...

Страница 23: ... 拆除前端外罩 连接保修监视器 选购 调整缩放与对焦 固定缩放与对焦控制杆 调整屏幕显示的设定 请参照屏幕显示乙节 卸除保修屏幕缆线 选购 装回前端外罩 需特别注意 1 检查橡胶密封垫是否装妥 及 2 紧密锁紧前端外罩 确保水气不会进入 前端外罩充分锁紧 前端外罩与外罩本体之间无间隙 可确保防止水气进入 前端外罩未充分锁紧 前端外罩与外罩本体之间有间隙 有水气进入风险 V X BNC母接头 接地接点 信号接点 端子台 端子台连接器 螺丝端子 指示 2 6x3 2 0 1x0 12 10 16 0 4 5 08 0 2 15 4 0 6 18 2 0 71 mm in 双稳压 DC12V AC24V 电源供应 Video In 电视监视器 分开销售 DC12V AC24V 双电压 摄像机 ...

Страница 24: ...手动 模式 快门 自动增益 快门 1 50 PAL 1 120 PAL 1 60 NTSC 1 100 NTSC 1 250 1 500 1 1000 1 2000 1 4000 1 10000 自动增益 6 12 18 24 30 36 42 44 8 返回 快门 光圈 快门与机械光圈都会依据亮度自动调整 自动光圈 预设 快门会维持在手动所选择的位置 且只使用光圈来调整亮度 主选单 第1层子选单 第2层子选单 第3层子选单 第4层子选单 白平衡 自动跟踪白平 衡 速度 000 255 延迟控制 000 255 自动跟踪白平衡框 x0 50 x1 00 x1 50 x2 00 环境设置 室内 室外 返回 推进 用户1 B增益 000 255 R增益 000 255 返回 用户2 B增益 000 255 R增益 000 255 返回 抑制色滚 手动 等级 NTSC 30 115 PAL 28...

Страница 25: ...000 255 色调 000 255 增益 000 255 返回 ATR 关 开 辉度 低 中 高 对比度 低 中等偏低 中 中等偏高 高 返回 ATR 自适应色阶再现 此功能提供了色调补偿 以提高存在同一个画面低亮度与高亮度等区域的主体 对比度 主选单 第1层子选单 第2层子选单 第3层子选单 第4层子选单 动域检测 开 检测灵敏度 000 127 块状显示 关 开 开启 控制 器 监视区域 开 关 区域选择 1 4 2 4 3 4 4 4 上 NTSC 000 244 PAL 000 288 下 NTSC 000 244 PAL 000 288 左 NTSC 000 474 PAL 000 468 右 NTSC 000 474 PAL 000 468 返回 关 下一页 退出 全部储存 ...

Страница 26: ...44 PAL 000 288 左 NTSC 000 474 PAL 000 468 右 NTSC 000 474 PAL 000 468 彩色 1 8 透明度 0 00 0 50 0 75 1 00 马赛克 关 开 返回 关 日 夜模式 自动 脉冲 关 开 延迟控制 0 255 日 夜 0 255 夜 日 0 255 返回 彩色 黑白 脉冲 关 开 IR自动补偿 关 开 模式 自动 固定 等级 0 31 返回 外部1 外部2 IR自动补偿 当已建立日 夜功能的夜间操作模式时 此模式会和外部红外LED光源一起使 用 可能会发生前端照明过度的情形 导致过度曝光 IR自动补偿的功能 能藉由最佳化夜间操作曝光控制 以降低这种过度曝光的 情形 重要注记 若用户想要让摄像机与摄像机模式及红外光线同步时 必需将日 夜模式设定在外部1 ...

Страница 27: ...显示选单结构 主选单 第1层子选单 第2层子选单 第3层子选单 第4层子选单 减噪 减噪模式 关 Y C Y C Y等级 000 015 C等级 000 015 返回 摄像机标示码 关 开 编辑模式 返回 语言 英语 日本语 德语 法语 俄语 葡萄牙语 西班牙语 中文 摄像机复位 上一页 退出 全部储存 重要注记 退出屏幕显示选单前 需先储存所有在摄像机设定上所做的变更 否则所有变更都会无效 将屏幕显示中之镜头选项从手动改为自动 可以自动将快门 自动增益控制设定 从自动光圈变为快门 自动光圈 默认值为自动 ...

Страница 28: ... p 复合 75Ω 镜头 变焦自动光圈与内建式DN镜头 镜头焦距 9 22mm 光圈 F1 6 360 镜头调整 内部 电子快门 1 60秒 1 50秒 逆光补偿 关闭 逆光补偿 高亮度补偿 白平衡 自动跟踪白平衡 推进 用户1 用户2 抑制色滚 手动 推进锁定 2DNR 开 关 等级可调整 自适应色阶再现 开 关 等级可调整 功能 镜像 亮度 对比度 锐度 色调 增益 动域检测 4个区域 隐私区域屏蔽 4个区域 语言 英语 日本语 德语 法语 俄语 葡萄牙语 西班牙语 中文 日 夜 真实日 夜转换 ICR 屏幕显示 内建 屏幕显示控制 内部 红外LED照射距离 m ft 850 nm 照射距离最高至60m 200ft 红外LED照射角度H V 24 24度 IP防护等级 IP66 防水 操作温度 30 至 50 22 至 122 储存温度 20 至 60 4 至 140 电力消耗 双重 ...

Страница 29: ...博世安防系统 使用手册 2012 11 室外日 夜子弹型摄像机 尺寸 简体中文版 29 8 1 尺寸 Ø70 2 75 148 5 82 120 4 72 约 257 10 1 60 2 36 mm in 126 4 96 Ø80 3 14 两个 3 Ø6 0 0 23 ...

Страница 30: ...博世安防系统 使用手册 2012 11 MEMO ...

Страница 31: ......

Страница 32: ...Bosch Security Systems www boschsecurity com c Bosch Security Systems 2013 ...

Отзывы: