1
Power supply, DC positive (10V - 30V)
2
Shield
3
Power supply (0V)
4
UPS (power good signal) - AC
5
UPS (power good signal) - Battery
6
UPS (power good signal) - DC
7
UPS (power good signal) - Common
Table 7.3: Power supply
1
Reader Supply (10V – 30V)
2
Reader Supply (0V)
3
Shield
4
Data RxTx+
5
Data RxTx-
6
Data shield (PAG)
7
not connected
8
not connected
9
not connected
10
not connected
Table 7.4: RS-485 reader interface
1
Analog Input, in
2
Analog Input, out
Table 7.5: Analog input