RS-232 Host Interface
The AMC2 offers an RS-232 serial interface to connect a host
computer or serial modem.
Notice!
Risk of malfunction
Cable length between two RS-232 COM serial interfaces must
not exceed 15 meters (45 ft).
Figure 4.14: Location of the RS-232 serial interface
As the AMC2 controller is conceptionally a PC, it is not possible
to connect them directly using normal cables. Use instead a null
modem or “crossover” cable. A complete connection diagram of
the RS-232 host interface is shown in chapter Connecting
Diagrams, page 58
4.10
34
en | Installing
Access Modular
Controller
2013-08 | AMC2-4R4 |
Bosch Sicherheitssysteme GmbH