Notice!
Enter telephone number when the Contact ID or SIA format is selected; enter IP address and
port number when the Bosch Network format is selected. Anti-replay for Receiver,
Acknowledge Wait Time for Receiver and Network Polling Time for Receiver are valid only
when using Bosch Network format.
Setting Telephone Number
For telephone number programming, See Telephone Programming Parameters, page 26
Setting IP Address and Port Number
The IP address is programmed with the 17 digits: Digits 1 - 12 for the IP address of the
receiver; 13 - 17 for the port.
It is not necessary to enter dots in programming, but 0 must be entered ahead of the digit to
make up 3 digits when each IP address unit is fewer than 3 digits. 0 must be entered ahead of
the digit to make up 5 digits when the port is fewer than 5 digits.
Example:
Receiver IP address 128.73.168.7, port 7700, should be made as: 128 073 168 007 07700
Dual IP Settings
Option
Address
Default
0 = 1 IP module, 1 = 2 IP modules
0120
1
Notice!
Dual IP Settings are valid only when used in the Connetix IP format. This programming option
is valid for B426 and ITS-DX4020-G modules. ITS-DX4020-G cannot be set as No. 2 IP module.
Module
Address
ITS-DX4020-G module or B426- module 1
134
B426 module 2
250
System Reporting
Option
Address
Default
Zone Status Restore Report
0121
6
AWAY Arming / Disarming Report
0122
6
EN=1/5/6/7
STAY Arming / Disarming Report
0123
6
EN=1/5/6/7
System Status Report (Zone fail, comm. fail, telephone
line fail, AC fail, low batterie...etc.)
0124
6
EN=1/5/6/7
Keypad Panic Alarm Report
0125
0
Keypad Fire Alarm Report
0126
0
Keypad Medical Alarm Report
0127
0
AMAX panel 4000 / AMAX panel 4000
EN
Configuration | en
21
Bosch Sicherheitssysteme GmbH
Quick Start Guide
2013.07 | 03 | F.01U.267.113
Содержание AMAX panel 4000
Страница 1: ...AMAX panel 4000 AMAX panel 4000 EN ICP AMAX4 P1 ICP AMAX4 P2 EN ICP AMAX4 P3 EN en Quick Start Guide ...
Страница 2: ......
Страница 70: ......
Страница 71: ......