Codes
Add/change user codes
This function is used if you want to add a code for a new user or
if you want to change the user permission levels or the code of
an existing user. Only master and installer users can add or
change user codes.
Notice!
Macros can only be used with a text keypad.
How to add/change user codes
1.
Enter your code + [5] [4] and press [#].
The system beeps twice and the STAY and AWAY indicators
start flashing.
2.
Enter a user number (1-64 for AMAX panel 2100, 1-128 for
AMAX panel 3000 and AMAX panel 3000 BE, 1-250 for AMAX
panel 4000) and press [#].
The current user permission level for this user is shown.
(Default for user number 2-64 is 6-Not used)
3.
Select the desired user permission level. You can choose
the following user permission levels for a code:
0-Master1 code
1-Master2 code
2-Super code
3-Basic code
4-Arming code
5-Duress code
6-Not used
Please refer to Quick keypad operations instructions, page 12
for a description of the user permission levels.
4.
Press [#].