Bypassing/isolating
If one or more zones are bypassed, they are disabled for one
arming cycle. After one arming cycle they are automatically
unbypassed.
If one or more zones are isolated, they are disabled until they
are unisolated.
After bypassing or isolating a zone, you can arm areas even
when a zone is in alarm state.
Bypassing/unbypassing zones
How to bypass/unbypass a zone via text keypad
1.
Enter your code + [3] [1] and press [#].
The STAY indicator flashes fast. The available zones are
shown. Already bypassed zones are checked. Unavailable
zones are marked with an x.
2.
Use [
▲
] and [
▼
] to display all zones.
3.
Select the zones you wish to bypass/unbypass with [*].
The selected zones are checked/unchecked.
4.
Press [#] to confirm and exit.
How to bypass/unbypass a zone via LED/LCD
keypad
1.
Enter your code + [3] [1] and press [#].
The STAY indicator flashes slowly. The slowly flashing
number indicators show the bypassed zones. If no numbers
are lit, no zones are bypassed yet.
2.
Enter the zone number you want to bypass/unbypass.
3.
Press [*].
The system beeps twice. The corresponding number
indicator is lit/extinguished.
4.
Repeat step 2 if you want to bypass/unbypass multiple
zones.
5.
Press [#] to exit.
7
7.1
7.1.1
7.1.2
AMAX panel
Bypassing/isolating | en
29
Bosch Sicherheitssysteme GmbH
2017.04 | 07 | F.01U.295.569