AMC2 enclosure with 1
DIN rail
Connections | en
15
Bosch Security Systems B.V.
2020-07 | V04 | F.01U.330.018
Connecting the main AC supply X
1.
Connect the ground cable to the main grounding point
(Figure 1.1, position 8).
2.
Connect the neutral wire to terminal N
(Figure 3.2).
3.
Connect the phase wire to terminal L1
(Figure 3.2).
4.
Shorten the external supply wires so that the ground wire
is a minimum of 20 mm longer than the live wires.
–
This will prevent the ground wire from being
accidentally disconnected.
Connecting the cover grounding cable
1.
Connect the mounted grounding cable (see position F of
Parts included, page 6) to the cover grounding point
(Figure 1.1, position 1) and to the grounding point on the
cover of the enclosure.
2.
Make sure that the screws of the two earthing points are
sufficiently tightened.
Refer to
–
–
3.3
Connections for supporting Universal
Power Supply
Precondition: Before switching to battery operation, disconnect
the AC power cable.
Notice!
Use 12 V 7 (7,2) Ah lead batteries only.
Notice!
Change the lead batteries every 5 years.
Содержание AEC-AMC2-UL01
Страница 1: ...AMC2 enclosure with 1 DIN rail AEC AMC2 UL01 en Installation manual ...
Страница 2: ......
Страница 28: ...28 Appendices AMC2 enclosure with 1 DIN rail 2020 07 V04 F 01U 330 018 Bosch Security Systems B V ...
Страница 29: ...AMC2 enclosure with 1 DIN rail Appendices 29 Bosch Security Systems B V 2020 07 V04 F 01U 330 018 ...
Страница 30: ...30 Appendices AMC2 enclosure with 1 DIN rail 2020 07 V04 F 01U 330 018 Bosch Security Systems B V ...
Страница 31: ......