24
en | Installing
Access Modular Controller 2
2021-04 | V04 | IM
Installation manual
Bosch Security Systems B.V.
4.9.1
RS-485 Two Wire Connection
Figure 4.11:
Setting of the jumpers for RS-485 two wire connections
4.9.2
RS-485 Four Wire Connection
Figure 4.12:
Settings for RS-485 four wire connection
Select the RS-485 address of the AMC2 controller using the DIP switch.
i
Notice!
If a four-wire connection is used the interface must be set up as a crosslink.
4.9.3
DIP switch selector
DIP switches are used to configure the host settings.
The first four DIP switches for address selection, define the RS-485 address of the AMC2 in an
RS-485 bus system.
Switch 5
selects one of the two different protocols, SDEB and BPA (according to DIN6619).
Switch 6
sets the connection to the host system to either RS-485 or the Project-specific
interface (PI).
i
Notice!
If using an Ethernet connection, set
switch 1
and
5
to
ON
(= delivery status).