Specifications
11
TR1000 12 B – 6 720 876 017 (2020/06)
3
Specifications
4
Special accessories
•
BZ45U20
Pipe set: for use of the continuous-flow heater as an under
sink appliance.
• Priority switch (load shedding relay)
BZ45L21
:
for operation with the priority circuit.
• Mounting set
BZ45K24M
: for surface-mount installation.
• Truncated connecting piece sealed at rear for water connection from
below (e. g. cold water connection via fitting mounted below heater):
5
Operating instructions
Please read and observe the detailed safety instructions at the start
of these instructions!
•
Important:
The appliance may never be exposed to frost!
WARNING:
Risk of electric shock!
Switch off the mains voltage supply immediately if a fault occurs.
• Immediately shut off the cold water supply to the appliance should
it leak.
6
Getting to know your appliance
The continuous-flow heater heats the water as it flows through the
appliance. The appliance only consumes power during this period.
This appliance can supply hot water to taps in several different locations.
It should be installed close to the tap that is used the most frequently.
This will enable you to reduce energy consumption.
7
Operating the appliance
• Turn on the hot-water tap.
The continuous-flow heater switches on automatically and heats the
water as it flows through the appliance.
The heater switches off again when you turn off the tap.
7.1
Increasing the water temperature
When the tap is turned on fully, it is possible that the heater capacity is
not sufficient to heat the water to the required temperature.
• Turn the tap off slightly. The water flows through the appliance more
slowly and reaches a higher temperature as a result.
7.2
Decreasing the water temperature
• Mix with cold water.
7.3
Saving energy
To minimise energy consumption when turning off the hot water:
• Turn off the hot-water tap slowly in order to use the residual heat of
the continuous-flow heater.
• This also prevents the water temperature from briefly increasing
above the preselected temperature if the hot-water tap is turned on
again within the next few minutes.
To obtain particularly uniform hot-water temperatures, it is
recommended to use thermostatically-controlled premixers.
The thermostatically-controlled premixer must be suitable for
hydraulically controlled continuous-flow heater.
7.4
Winter operation
Note:
It is possible in winter that the supply temperature of the water is
reduced and the required outlet temperature is no longer achieved.
TR1000 12 B
Rated power as delivered [kW] / Rated voltage
Connection Options
12 kW Y 400 V 3 ~ (11 kW Y 380 V 3 ~)
8.0 kW 230 V ~ (7.4 kW 220 V ~)
6.0 kW 230 V ~ (5.5 kW 220 V ~)
Switch-on point [I/min]
3.6
Mixed water [I/min] at rated power
approx. 38 °C
6.5
approx. 50 °C
(supply temperature 12 °C)
4.4
Maximum flow pressure of appliance [MPa (bar)]
1.0 (10)
Minimum flow pressure of appliance [MPa (bar)]
1)
1)
Plus any pressure loss at the tap mixer.
with flow limiter
0.3
without flow limiter
0.2
Maximum inlet water temperature [ °C]
20
Energy efficiency class
A
Load profile
XS
Annual energy consumption [kWh]
474
Daily energy consumption [kWh]
2,170
Sound power level [dB]
15
Hot water heating energy efficiency [%]
39
Elbow joint, “cold” (right)
Order no.
056169
Elbow joint, “hot”, (left)
Order no.
255568
Содержание 7736504685
Страница 36: ...TR1000 12 B 6 720 876 017 2020 06 36 1 ...
Страница 37: ...37 TR1000 12 B 6 720 876 017 2020 06 2 ...
Страница 38: ...TR1000 12 B 6 720 876 017 2020 06 38 3 ...
Страница 39: ...39 TR1000 12 B 6 720 876 017 2020 06 4 ...
Страница 40: ...TR1000 12 B 6 720 876 017 2020 06 40 5 ...
Страница 41: ...41 TR1000 12 B 6 720 876 017 2020 06 6 7 ...
Страница 42: ......
Страница 43: ......
Страница 44: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...