6 720 644 942 (2014/11)
520 HN
18 | Installation instructions
GAS LINE SIZING
The gas supply piping should be sized according to the applicable code for a maximum draw of 117,000 BTUH. Measure the length
of gas supply line and use the tables in Fig. 14 or the gas line manufacturer’s sizing tables to determine the pipe diameter necessary
to accommodate the BTU demand of the unit. If there are more gas appliances drawing on the same line, size the gas line according
to the total maximum amount of BTU draw for all appliances.
Note:
Under sizing the gas line may result in diminished output. See chapter 3.7 for the procedure to measure gas pressure.
FOR NATURAL GAS
Maximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure drop of 0.3 in Water
Column (0.75mbar).(Based on a 0.60 Specific Gravity Gas) Btu numbers given in thousands.
Copper tubing is prohibited for use with Natural Gas in the Commonwealth of Massachusetts and not recommended elsewhere.
Follow boxed numbers for piping just one 520 HN (example: ¾” B.I. Natural Gas pipe for 20 ft (6.1m). will handle 190,000 btu’s
(55.7 kWh). For multiple appliances combine the total btu input load and then refer to applicable chart below.
* EHD = Equivalent Hydraulic Diameter. The greater the value EHD, the greater the gas capacity of the tubing.
Lenght of Black Iron Pipe, Feet
Nominal
Iron
Pipe
Size
Inches
Internal
Diameter
inches
10
20
30
40
50
60
70
80
90
100
125
150
175
200
3/4
0.824
278
190
152
130
115
105
96
90
84
79
72
64
59
55
1
1.049
520
350
285
245
215
195
180
170
160
150
130
120
110
100
1 - 1/4
1.380
1050 730
590
500
440
400
370
350
320
305
275
250
225
210
Table 7
Tube
size,
Inches
EHD*
Lenght of Flexible Corrugated Stainless Steel Tubing (CSST), Feet
10
20
30
40
50
60
1/2
18
82
58
47
41
37
34
3/4
23
161
116
96
83
75
68
1 30
330
231
188
162
144
131
1 - 1/4
37
639
456
374
325
292
267
Table 8
Содержание 520-HN -L
Страница 36: ......