English |
17
– Mark the centre of the laser line on wall A as point
Ⅲ
(vertically above or
below point
Ⅰ
).
– The discrepancy
d
between the two marked points
Ⅰ
and
Ⅲ
on wall A re-
veals the actual horizontal deviation of the measuring tool.
The maximum permitted deviation on the measuring distance of
2 ×
5
m =
10
m is as follows:
10
m × ±
0.5
mm/m = ±
5
mm. The discrepancy
d
between points
Ⅰ
and
Ⅲ
must therefore amount to no more than
5
mm.
Checking the Levelling Accuracy of the Vertical Lines
For this check, you will need a door opening (on solid ground) which has at
least 2.5 m of space either side of the door.
– Place the measuring tool 2.5 m away from the door opening on a firm, flat
surface (not on a tripod). Select vertical mode with automatic levelling.
Aim the vertical laser line at the door opening and allow the measuring
tool to level in.
2,5 m
2,5 m
– Mark the centre of the vertical laser line on the floor of the door opening
(point
Ⅰ
), 5 m away on the other side of the door opening (point
Ⅱ
) and on
the upper edge of the door opening (point
Ⅲ
).
Bosch Power Tools
1 609 92A 58R | (04.03.2020)
Содержание 3 601 K63 A01
Страница 3: ... 3 1 2 3 5 6 7 8 9 4 Bosch Power Tools 1 609 92A 58R 04 03 2020 ...
Страница 4: ...4 10 11 12 13 4 15 1 608 M00 05B 14 0 601 096 B00 BT 150 1 609 92A 58R 04 03 2020 Bosch Power Tools ...
Страница 5: ... 5 X X X A B Bosch Power Tools 1 609 92A 58R 04 03 2020 ...
Страница 6: ...6 C D 1 609 92A 58R 04 03 2020 Bosch Power Tools ...