English |
23
Switching On/Off
To
switch on
the measuring tool, slide the on/off switch
(2)
to the
ON
position. As soon
as it is switched on, the measuring tool emits laser beams from the outlet apertures
(1)
.
u
Do not direct the laser beam at persons or animals and do not stare into the laser
beam yourself (even from a distance).
To
switch off
the measuring tool, slide the on/off switch
(2)
to the
OFF
position. The
pendulum unit is locked when the tool is switched off.
u
Never leave the measuring tool unattended when switched on, and ensure the
measuring tool is switched off after use.
Others may be blinded by the laser beam.
If the maximum permitted operating temperature of
45
°C is exceeded, the tool shuts
down to protect the laser diode. Once it has cooled down, the measuring tool is opera-
tional again and can be switched back on.
Automatic shut-off
The measuring tool automatically switches itself off after
60
min of operation.
If the switched on measuring tool is not within the self-levelling range (the laser points
flash continuously), the automatic shut-off is reset to
60
min.
Automatic Levelling
Position the measuring tool on a level, firm support or attach it to a tripod
(11)
.
To use the bottom laser point, rotate the measuring tool on the magnetic rotating
mount
(3)
in such a manner that the laser point can be seen on the floor.
After switching on, the automatic levelling function automatically compensates irregular-
ities within the self-levelling range of ±
4
°. The levelling is finished as soon as the laser
points light up continuously (i.e. no longer flashing) and do not move any more.
If automatic levelling is not possible, e.g. because the surface on which the measuring
tool stands deviates by more than
4
° from the horizontal plane, the laser points will flash
continuously and quickly.
If this is the case, set up the measuring tool in a level position and wait for the self-level-
ling to take place. As soon as the measuring tool is within the self-levelling range of ±
4
°,
the laser points will light up continuously.
In case of ground vibrations or position changes during operation, the measuring tool is
automatically levelled again. After each levelling process, check the position of the hori-
zontal and/or vertical laser points in relation to the reference points to avoid errors
arising from a change in the measuring tool's position.
Bosch Power Tools
1 609 92A 5MH | (22.10.2020)
Содержание 0 601 066 N00
Страница 3: ... 3 GPL 5 G GPL 5 G GPL 3 G 1 1 2 3 Bosch Power Tools 1 609 92A 5MH 29 10 2020 ...
Страница 4: ...4 1 4 5 6 7 8 9 1 8 GPL 5 G 1 609 92A 5MH 29 10 2020 Bosch Power Tools ...
Страница 5: ... 5 GPL 5 G GPL 5 G click A B C Bosch Power Tools 1 609 92A 5MH 29 10 2020 ...
Страница 6: ...6 D E 12 10 1 608 M00 05J 11 BT 150 0 601 096 B00 1 609 92A 5MH 29 10 2020 Bosch Power Tools ...