Electrical Connections
5–5
1070 073 822-104 (02.06) GB
5.3
Power supplies
5.3.1
24V
DC
power supply
X10_1
24 VDC power connection (w/ integrated 24 VDC power supply)
Alternative to 230/115 VAC power connection. All internally required volt-
ages are provided by a DC/DC converter.
Weidmüller push-lock terminal, MSTB 1.5, 4-pin
Max. conductor cross-sect.:
1.5 mm
2
(see next page)
X10_1
2
1
3
4
Pin
Signal
1
24V
2
3
24V
0V
0V
4
+
+
–
–
Rated voltage U
N
:
24 VDC ; +20%, –15%
Residual ripple at U
N
:
See diagram below
Interference / surge immunity:
U
max
= 35 V (at t < 100 ms)
Current draw at U
N
:
max. 5 A
Input fuse:
6.3 A (5x20) medium time-lag
Reverse polarity protection:
Via decoupling diode. Polarity reversal will blow
input fuse.
DANGEROUS ELECTRICAL VOLTAGE
The 24 VDC input voltage must satisfy the requirements of ”protec-
tive separation”!
Safety transformer, as per EN 60742
PE
L1 L2 L3
0V
+ 24V
400V +5%
400V
400V −5%
Содержание IPC
Страница 1: ...Antriebs und Steuerungstechnik IPC IPC300 Connectivity Manual Industrial PC 104 Edition ...
Страница 12: ...Safety Instructions 1 8 1070 073 822 104 02 06 GB Notes ...
Страница 18: ...IPC System Overview 2 6 1070 073 822 104 02 06 GB Notes ...
Страница 70: ...Interfaces Ports Connectors 6 22 1070 073 822 104 02 06 GB Notes ...
Страница 72: ...LED Display 7 2 1070 073 822 104 02 06 GB Notes ...
Страница 75: ...Maintenance and Replacement 8 3 1070 073 822 104 02 06 GB IPC300 Fuse ...
Страница 88: ...Maintenance and Replacement 8 16 1070 073 822 104 02 06 GB Notes ...