10.3 Pin assignment
The Vin-LED is green if the power
supply is provided
CDI interface to control cabinet PC
Changeover input
input "SEL"
Power supply
"24V"
CDI interface to o p e ra to r d is p la y n o . 1
CDI interface to o p e ra to r d is p la y n o . 2
Functional earth (to be
connected)
If 24 V are applied at the SEL input, the operation
at the operator display no. 2 is enabled.
The LEDs at XSER2 and XVID2 are on
If 0 V are applied at the SEL input, the operation
at the operator display no. 1 is enabled.
The LEDs at XSER1 and XVID1 are on
If 24 V are applied at the "ESM" input,
the Energy S ave Mode is enabled at the inactive
operating display (only Y-Repeater
VAC01.1S-YD1-TCES)
Fig. 10-3: Connections of the Y-repeater
10.4 Mounting
1. Mounting the Y-repeater to the rear panel
The distances of the mounting holes are listed in
the Y-repeater – rear panel" on page 16
Use two M5 screws to attach the Y-repeater to the rear panel.
2. Fixing the cables
Unfixed cables are not permitted. Therefore, an appropriate fixing (e. g. in-
stallation in a cable channel) and a strain relief of the cables is required.
10.5 Demounting
Preparing the demounting
1. Demounting the Y-repeater from the rear panel
Remove the both M5 screws used to attach the Y-repeater to the rear pan-
el.
Bosch Rexroth AG
Mounting, demounting and electric installation
Y-Repeater
18/33
DOK-SUPPL*-VAC*01*****-IT03-EN-P
Содержание IndraControl VAC 01
Страница 1: ...IndraControl VAC 01 Y Repeater Operating Instructions R911336973 Edition 03 ...
Страница 6: ...Bosch Rexroth AG Y Repeater IV DOK SUPPL VAC 01 IT03 EN P ...
Страница 36: ...Bosch Rexroth AG Y Repeater 30 33 DOK SUPPL VAC 01 IT03 EN P ...
Страница 39: ...Notes Y Repeater Bosch Rexroth AG ...