RA 17038/02.13
|
CDT1/CGT1
Industrial Hydraulics |
Bosch Rexroth Corp.
9
/44
Bore Ø
SAE Port NPT Port
In.
E
EE
EE
F
FB
G
J
K
R
TF
UF
LB
P
1.500
2.00
-6
3/8
0.38
0.31
1.50
1.00
0.25
1.43
2.75
3.38
4.00
2.25
2.000
2.50
-6
3/8
0.38
0.38
1.50
1.00
0.31
1.84
3.38
4.13
4.00
2.28
2.500
3.00
-6
3/8
0.38
0.38
1.50
1.00
0.31
2.19
3.88
4.63
4.13
2.28
3.250
3.75
-10
1/2
0.63
0.44
1.75
1.25
0.38
2.76
4.69
5.50
4.88
2.63
4.000
4.50
-10
1/2
0.63
0.44
1.75
1.25
0.38
3.32
5.44
6.25
4.88
2.69
5.000
5.50
-10
1/2
0.63
0.56
1.75
1.25
0.44
4.10
6.63
7.63
5.13
2.94
6.000
6.50
-12
3/4
0.75
0.56
2.00
1.50
0.44
4.88
7.63
8.63
5.75
3.13
Bore
MM
In.
Rod
V
W
Y
ZB
ZF
ZJ
1.500
0.625
0.25
0.63
1.94
4.88
5.00
4.63
1.000
0.50
1.00
2.31
5.25
5.38
5.00
2.000
0.625
0.25
0.63
1.94
4.94
5.00
4.63
1.000
0.50
1.00
2.31
5.31
5.38
5.00
1.375
0.63
1.25
2.56
5.56
5.63
5.25
2.500
0.625
0.25
0.63
1.94
5.06
5.31
4.75
1.000
0.50
1.00
2.31
5.44
5.50
5.13
1.375
0.63
1.25
2.56
5.69
5.75
5.38
1.750
0.75
1.50
2.81
5.94
6.00
5.63
3.250
1.000
0.25
0.75
2.38
6.00
6.25
5.63
1.375
0.38
1.00
2.63
6.25
6.50
5.88
1.750
0.50
1.25
2.88
6.50
6.75
6.13
2.000
0.50
1.38
3.00
6.63
6.88
6.25
4.000
1.000
0.25
0.75
2.38
6.00
6.25
5.63
1.375
0.38
1.00
2.63
6.25
6.50
5.88
1.750
0.50
1.25
2.88
6.50
6.75
6.13
2.000
0.50
1.38
3.00
6.63
6.88
6.25
2.500
0.63
1.63
3.25
6.88
7.13
6.50
5.000
1.000
0.25
0.75
2.38
6.31
6.50
5.88
1.375
0.38
1.00
2.63
6.56
6.75
6.13
1.750
0.50
1.25
2.88
6.81
7.00
6.38
2.000
0.50
1.38
3.00
6.94
7.13
6.50
2.500
0.63
1.63
3.25
7.19
7.38
6.75
3.000
0.63
1.63
3.25
7.19
7.38
6.75
3.500
0.63
1.63
3.25
7.19
7.38
6.75
6.000
1.375
0.25
0.88
2.78
7.06
7.38
6.63
1.750
0.38
1.13
3.03
7.31
7.63
6.88
2.000
0.38
1.25
3.16
7.44
7.75
7.00
2.500
0.50
1.50
3.41
7.69
8.00
7.25
3.000
0.50
1.50
3.41
7.69
8.00
7.25
3.500
0.50
1.50
3.41
7.69
8.00
7.25
4.000
0.50
1.50
3.41
7.69
8.00
7.25
Dimensions MF1, MF2, MF5, MF6
Table 1 - Dimensions affected by rod diameter
Table 2 - Dimensions not affected by rod diameter
Flange mounts are one of the stron-
gest, most rigid methods of mounting.
With this type of mount, there is little
allowance for misalignment, so when
long strokes are required, the free end
opposite the mounting should be sup-
ported to prevent sagging and possible
binding of the cylinder. Blind or cap
end mounts are best for thrust load ap-
plications, and rod or head end mounts
are best in tension applications. If an
application exceeds the rectangular
flange rating, a solid head or cap flange
mount is available.
When a less rigid mount can be used
and the cylinder can be attached to a
panel or bulkhead, an extended tie rod
mount could be considered.
Note: The bearing retainer plate is the
same as the “E” dimension for the 1.5”
– 6” bore sizes. Removable bearing
retainer is not available in the 1.5” – 6”
bore sizes.
Rod end options shown on page 6.