Online measurement
107
11.4.2
Setting up the group adjustment trigger channel
1.
Click on ‘Measurement Sources’ in the Toolbox.
1.
Drag the ‘Group Adjustment Channel’ element from the Toolbox and drop it on the DDU 7.
A ‘Group Adjustment Channel Wizard’ opens.
Note: If a low-active signal is selected as an input channel, do not forget to enable the pull-up
resistor for the pin. Otherwise the group adjustment will be triggered periodically. See chapter
‘10.3.2 Configuring a generic linear sensor‘for further information concerning the pullup-resistor.
Check the box to activate the
internal DDU 7 pullup-resistor
and set the resistor value
Select the pin to which the
sensor shall be connected
Drag + drop