Bosch Motorsport DDU 7 Скачать руководство пользователя страница 1

 

 

 

 

Bosch Motorsport 

Display DDU 7 

Manual 
 

F 02U 003 052-01 

 

Содержание DDU 7

Страница 1: ...Bosch Motorsport Display DDU 7 Manual F 02U 003 052 01 ...

Страница 2: ......

Страница 3: ...ation 34 8 3 LEDs 43 8 4 Page select 49 8 5 Display LED brightness 51 8 6 Math condition channels 52 8 7 Condition channels 57 9 CAN bus 61 9 1 CAN bus trivia 61 9 2 CAN input 62 9 3 CAN output 71 10 Analog and frequency inputs 75 10 1 DDU 7 features 75 10 2 Analog inputs 76 10 3 Configuring inputs 77 10 4 Computed sources 91 10 5 Hysteresis 93 11 Online measurement 97 11 1 Achieving an online con...

Страница 4: ... 13 5 Countdown timer 147 14 Firmware 148 14 1 Firmware and configuration 148 14 2 Firmware update 149 15 GPS sensor 151 15 1 GPS Global Positioning System 151 15 2 Protocol 151 15 3 Sensor recommendation 152 15 4 Measurement labels 152 15 5 GPS troubleshooting 153 16 Fuel consumption calculation 154 16 1 Setting up fuel consumption calculation and tank management for DDU 7 154 16 2 Fuel consumpti...

Страница 5: ...nd other devices outside the scope of this manual are only permitted when they have been determined to be compliant from a performance and safety standpoint by a representative from Bosch Motorsport Read the manual carefully and follow the application hints step by step Don t hesitate to contact us contact data can be found on the last page of this document Disclaimer Due to continuous enhancement...

Страница 6: ...t anodizing etc Use large diameter wire More metal to metal contact is better The following notations for power signals are used KL 15 is a switched battery rail controlled by the IGN switch KL 30 is an unswitched battery positive rail same as battery positive terminal KL 31 is an unswitched ground rail same as battery negative terminal Be careful to observe current limits of wires and connector p...

Страница 7: ...ift lights 8 kHz AD converters with digital low pass filter Configurable math channels User configurable CAN in out messages Up to 1 000 Hz acquisition rate for all channels Online data compression Up to 100 kB s data acquisition rate Up to 720 recording channels 1 000 kB s upload rate 2 GB internal storage capacity FM 40 long range telemetry support GSM telemetry support RS232 GPS input Supported...

Страница 8: ... battery for data preservation included Required service interval 12 months internal battery is replaced Accessories External switch for page selection 12 step switch B 261 209 658 External switch for brightness adjustment or page selection 6 step switch B 261 209 659 Rugged USB Flash drive and connector are available on request Software Upgrades Software Upgrade 1 F 02U V01 134 01 CCP Master ASAP...

Страница 9: ...ensor to the REVn_P pin and leave the REVn_M pin open 5 1 3 Page selection switch Pin 36 of the DDU 7 life connector is used as a page selection switch for the display The internal pull up resistor is automatically activated Display pages are selected by connecting the pin to SENSGND with different resistor values over a 12 position switch Page Resistor Value Page 1 43 9 Ohm Page 2 142 Ohm Page 3 ...

Страница 10: ... values over a 6 position switch The individual brightness settings for LEDs and the display are defined by RaceCon Dim Level Resistor Value Level 1 43 9 Ohm Level 2 142 Ohm Level 3 264 Ohm Level 4 409 Ohm Level 5 609 Ohm Level 6 846 Ohm 5 2 Output channels 5 2 1 Sensor power supply The DDU 7 has 2 types of sensor power supply 5 V and 10 V regulated voltage The regulated 5 V and 10 V outputs can d...

Страница 11: ...l ports Baudrate for both ports is programmable RS232 port 1 is reserved for online telemetry port 2 can be used for reception of data from a serial GPS receiver 5 3 4 Vehicle diagnosis connector The Bosch Motorsport vehicle diagnosis connector is used as a standard interface to connect the vehicle to a PC e g via a MSA Box II Loom connector AS 0 12 35SN Pin Name Description Used for DDU 7 Pin 1 T...

Страница 12: ...g signal 3 input 18 ANA04 analog signal 4 input 19 ANA07 analog signal 7 input 20 ANA08 analog signal 8 input 21 RS232_GPS_TX RS232_GPS transmit data bidirectional dataline used for GPS sensor 22 ETH_SCR screen for Ethernet screen 23 REV3 speed signal 3 input 24 25 ETH1_RX ETH1_TX Ethernet interface 1 10 100BaseT bidirectional dataline 26 REV4 speed signal 4 input 27 LAP_TRIG laptrigger input inpu...

Страница 13: ...6 Mechanical drawing ...

Страница 14: ...tionality Minimum wiring loom of the Life connector red Pin Description Pin 1 2 3 12 V supply voltage Pin 4 5 GND supply voltage Pin 6 Ethernet Tx Pin 7 Ethernet Tx Pin 8 Ethernet Rx Pin 9 Ethernet Rx Pin 10 Ethernet Screen 7 1 1 Setting up the network interface The DDU 7 contains a DHCP server network addresses can be assigned automatically to the configuration PC The DDU 7 s IP address is 10 10 ...

Страница 15: ...er will illuminate If the LED is off check the wiring harness 7 1 3 About RaceCon RaceCon is an all integrated software tool for configuration and calibration of Bosch Motorsport hardware products It is used to set up configure and calibrate the DDU 7 For better understanding Bosch Motorsport offers a video tutorial that explains many functions of RaceCon The video tutorial is available in the Sof...

Страница 16: ...up the DDU 7 16 7 1 4 Connecting the DDU 7 to RaceCon The following screenshot shows an overview of the RaceCon Main Screen with its areas All sub windows are resizable and dockable 1 Start the RaceCon software ...

Страница 17: ...ng up the DDU 7 17 2 In the File menu select New to create a new project 3 In the Toolbox select the DDU 7 and drag it into the Main Area A pop up window to specify the DDU 7 program archive appears Drag Drop ...

Страница 18: ...archive delivered with the DDU 7 PST file 5 Click Next 6 Select Race track 7 Choose the way to switch display pages that fits to your hardware configuration For more information see chapter 8 4 Page select 8 Click Finish The DDU 7 is inserted into the project and RaceCon tries to connect to the device ...

Страница 19: ...cts configuration differences between the DDU 7 and the RaceCon project and asks for permission for data download 9 Click OK to proceed The download starts and the DDU 7 carries out a reset Successful Ethernet connection DDU 7 talks to PC ...

Страница 20: ...er the reset RaceCon reconnects to the DDU 7 Local configuration on both the PC and DDU 7 match Indicated by green background and dot The DDU 7 is now connected to RaceCon Green back ground and dot indicate matching configuration ...

Страница 21: ...equires activating once only As the activation key is device specific a key delivered with one DDU 7 does not work on any other DDU 7 If you have not purchased an option package the next steps can be skipped 1 To activate a feature double click on DDU 7 in the Project Tree and click on the Features info tab in the Main Area The DDU 7 features info window appears Feature status Locked disabled Unlo...

Страница 22: ...k window appears 3 Enter the activation key you received for this feature on this device and click OK when done The feature s status changes to unlocked 4 Perform these steps to activate other features you purchased 5 Switch the car s ignition off and on again to cycle the power of the DDU 7 ...

Страница 23: ...uration of a display element showing the battery voltage See chapter 8 2 Display element configuration for a detailed instruction to configure display elements 1 Expand the DDU 7 Project Tree by clicking 2 Double click on New Page The DDU 7 display configuration area opens Click Double click New Page ...

Страница 24: ...e A message in the Large Element box shows that it is not linked to a measurement channel 4 In the DDU 7 Project Tree click on DDU 7 to display the available measurement channels 5 In the data window scroll down to ub measurement channel for battery voltage Drag Drop Scroll down to ub Click DDU 7 ...

Страница 25: ... DDU 7 25 6 Drag the ub measurement channel from the Data Area and drop it on the Large Element 7 Right click on DDU 7 in the DDU 7 Project Tree and choose Download Configuration Drag Drop Click Download configuration ...

Страница 26: ...Starting up the DDU 7 26 The configuration download starts and the DDU 7 carries out a reset The value of the battery voltage is displayed on the DDU 7 ...

Страница 27: ...battery voltage channel See chapter 12 Recording and telemetry for a detailed instruction to configure recordings 1 Expand the DDU 7 Project Tree by clicking 2 Expand the Logger Tree by clicking 3 Double click on Recording The DDU 7 recording configuration area opens 3rd Double click Recording 2nd Click Logger 1st Click ...

Страница 28: ... Tree click on DDU 7 to display the available measurement channels 5 In the data window scroll down to ub measurement channel for battery voltage 6 Drag drop the ub measurement channel into the recording area Drag Drop Click DDU 7 Scroll down to ub ...

Страница 29: ... on DDU 7 in the DDU 7 Project Tree and choose Download configuration The configuration download starts and the DDU 7 carries out a reset As we did not define global start conditions recording starts immediately Click Download configuration ...

Страница 30: ...ata logger C50 C55 C60 DDU7 DDU8 and click OK when done The Read measurement Data dialog opens 12 Click on Modify button and select the base folder 13 Choose FTP as data transmission method 14 Choose DDU7 10 10 0 207 in the Vehicle dropdown list 15 Activate Auto save 16 Click Save when done Choose DDU7 in dropdown list Click Import Export ...

Страница 31: ...19 Click on the Start button and choose Open measurement file 20 Select the measurement files from the storage folder 21 Click on Open 22 Click in New Desktop to open a new measurement data window 23 Drag the ub measurement channel from the Channel list and drop it into the measurement data window ub measurement channel s graph is displayed Note For more detailed descriptions and instructions refe...

Страница 32: ...isplay pages 6 brightness settings for display and LEDs 8 1 Display page setup 8 1 1 Organizing display pages All Pages Display elements placed on this page are displayed on all pages Recommended for Alarm display elements Single Page Display elements placed on this page are displayed only on this page The priority of display elements placed on All Pages is higher than the priority of display elem...

Страница 33: ...menu A new empty page opens 8 1 3 Selecting display pages In the DDU 7 Project Tree click on DDU 7 then on Display and double click on the page you want to select example New Page In the Main Area a representation of the DDU 7 opens Configurable LEDs Display area Tabs to switch between different items pages ...

Страница 34: ...d font size The element and font size can be changed using the Numeric Wizard 1 Drag a numeric display element from the Toolbox and drop it on the display page A message in the numeric element box shows that it is not linked to a measurement channel 2 Drag a measurement channel from the Data Area and drop it on the numeric display element The measurement channel is linked to the numeric display el...

Страница 35: ...layed in the middle of the numeric display element The variable channel value displays the value of the measurement channel c Choose the measurement channel d Choose the type of input data Value Gear Time in different formats e Enter the number of decimal places of the measurement channel f Choose the font size alignment borderstyle background and foreground color of the numeric display element g ...

Страница 36: ...oose the orientation of the Bargraph horizontal or vertical e Chose the color mode of the Bargraph Solid The whole Bargraph and tics are colored in one color Stacked The Bargraph is subdivided in segments with different colors The colors are set in the tab Conditional Formatting For details see chapter 8 2 5 Conditional formatting f Define if ticks and numbers are shown g Choose the style of the b...

Страница 37: ...page Drag an Alarm element from the Toolbox and drop it on the display page Configuring an Alarm text display element 1 Double click on the Alarm display element The Alarm Wizard window opens a Enter the title displayed on top of the Alarm display element b Choose the condition when the alarm will be activated Create a condition using the Condition Creator For more information see chapter 8 7 1 Cr...

Страница 38: ...resentation a Choose if the alarm can be reset or not b Choose if the alarm blinks slowly fast or does not blink c Enter the minimum time the Alarm display element is displayed if an alarm is triggered d Enter the time until the Alarm resets automatically after the minimum display time entered in c Only possible if Alarm is resettable e Enter the time until the Alarm can appear again after a reset...

Страница 39: ...ition The Alarm Icon is displayed if function is TRUE i e result of the calculation is 0 c Enable the checkbox if you want to define parts of the image as transparent d Select the basic transparent color key This means that any pixel of the image near depending of the tolerance value to this color gets transparent e Select a tolerance in percent to define parts of the image as transparent 2 Switch...

Страница 40: ...e Toolbox and drop it on the display page Configuring a Label display element 1 Double click on the Label display element The Label Wizard window opens a Enter the title displayed on top of the Label display element b Enter the text displayed in the middle of the Label display element c Choose the font size alignment borderstyle background and foreground color of the Label display element d Click ...

Страница 41: ...window opens a Select the image from the hard drive b Enable the checkbox if you want to define parts of the image as transparent c Select the basic transparent color key This means that any pixel of the image near depending of the Tolerance value to this color gets transparent d Select a tolerance in percent to define parts of the image as transparent 2 Click OK when done a c d b ...

Страница 42: ...he lower and the upper limits are configured in the same way a Check the box to activate the formatting at a lower limit b Enter the limit value when the formatting is active c Enter the limit value when the reset hysteresis function is active The reset hysteresis function avoids the high frequent switchover of the measurement channel value d Choose the borderstyle background and foreground color ...

Страница 43: ... Configuring shift LEDs To use shift LEDs RPM and gear measurement channels an ECU has to be loaded in RaceCon 1 In the display view click on the tab LEDs 2 Click on the button Add shift lights Change type of display element Move element to different page Remove assigned measurement channel Delete element Manage overlapping elements Insert element into library in toolbox Show and edit properties C...

Страница 44: ...ally for each LED and each gear f Choose the measurement channel for Gear Gear must have an ASCII quantization 1st gear 1 49 2nd gear 2 50 ASCII quantization is standard for the gear channel of Bosch ECUs If you get the gear information of a different control unit as the Bosch ECU e g a gearbox control unit use the Gear Lookup Table to translate numeric values to ASCII format For more information ...

Страница 45: ...es button in the Toolbox 2 Drag the Gear Lookup Table symbol and drop it in the Computed Channels folder The Gear Lookup Table Wizard appears 3 Set up the settings as shown in the screenshot 4 Click OK when done Choose the input channel of the gear information This column shows the numeric value of the input channel Enter the default ASCII value that is set if no output value is entered in the tab...

Страница 46: ...w appears 5 Enter the name and an optional description of the translated ASCII measurement channel 6 Click Ok when done A graphic shows the connection between the input and output channels The measurement channel can now be used in the shift LED configuration ...

Страница 47: ...o not blink c Choose the condition when the LEDs will flash Create a condition using the Condition Creator For more information see chapter 8 7 1 Creating a new condition channel Choose an existing condition d Check the box to show a demo of the LEDs Important to check blinking To create a LED that alternately blinks in two different colors choose Display on pattern and define the LEDs in the one ...

Страница 48: ...rn and shift lights The 1st display pattern is activated before all following pattern if its condition is true The 2nd display pattern is only activated if the condition of the 1st display pattern is false or the LEDs of the 1st display pattern are transparent Change the priority by clicking the Move up or Move down button ...

Страница 49: ... pull up resistor in DDU 7 automatically activated 12 position switch connects resistor to GND 43 9 142 264 409 609 846 1180 1650 2430 3830 6980 23200 Ohm Connection diagram of 12 position switch Note If pin ANA01 is open or directly connected to GND the DDU 7 displays Page 1 by default Display pages selectable by page select switch ...

Страница 50: ...plication page control from steering wheel or motorcycle Display page selected at power down will show up at next power up automatically The software calibration variable DISPLAY_SWITCH needs to be set 0 Rotary switch 1 Up Down switch 2 Up Down switch with wrap around By default the DDU 7 is configured for a 12 position rotary switch Connection diagram of up down switches Note De bounce time of sw...

Страница 51: ...ivated 6 position switch connects resistor to GND 43 9 142 264 409 609 846 Ohm Connection diagram of brightness switch Write configuration to DDU 7 to activate changed brightness settings Position of brightness switch Click on the Settings tab to display brightness controls Setting for display brightness of maximum Setting for LED brightness of maximum ...

Страница 52: ...ject Conditional function Arithmetic and logical operations on one or more measurement channel s If Else structure with reset Numerical result Result can be used as input source for various display elements numeric elements alarms Bargraphs and further calculations in the whole RaceCon project All math channels can be used globally in the whole DDU 7 project 8 6 2 Creating a new math channel 1 Fol...

Страница 53: ...he math channel b Enter a description of the math channel c Enter the formula d Select the logical operator e Choose a measurement channel f Define a value that can be used as a constant in the formula g Choose a function h Describes the function selected above 3 Click Finish when done The math channel is displayed in the DDU 7 math channel window d c e f a b g h ...

Страница 54: ...n 54 8 6 3 Creating a new conditional function 1 Follow the steps shown in the screenshot 2nd Click on the dropdown arrow beside Add channel 3rd Choose Conditional Function 1st Double click on Math Channels in Project Tree ...

Страница 55: ...value is always set for the new variable entered in Name before If condition becomes TRUE for the first time after power up when If condition changes state from FALSE to TRUE An example of a condition to set up the maximum front brake pressure is given on the next page 2 Define the conditional function using the following configuration possibilities a Enter the name of the conditional function b E...

Страница 56: ... 40 As p_br_front 40 is bigger than p_br_front_mx 30 the new value for p_br_front_mx is set to 40 As p_br_front falls below 20 the IF condition turns to FALSE Now the OTHERWISE condition is triggered Because the condition p_br_front_mx sets the value of p_br_front_mx and the value that is already set to 40 before nothing changes When p_br_front rises to 40 the If condition changes to TRUE again an...

Страница 57: ...ents and further calculations in the whole RaceCon project Condition combination Combination of several up to 16 condition channels for more complex calculations Logical result All condition channels can be used globally in the whole DDU 7 project 8 7 1 Creating a new condition channel 1 Follow the steps shown in the screenshot 1st Double click on Conditional Channels in Project Tree 2nd Click on ...

Страница 58: ...el Choose the measurement channel or condition the operator and the measurement channel or condition to be compared Range Choose the measurement channel or condition the operator and define the minimum and maximum value Multiple Choose the measurement channel or condition the operator and enter the value of up to 5 constants d Enter the minimal time to detect the signal of the measurement channel ...

Страница 59: ...splayed in the DDU 7 condition channel window 8 7 2 Creating a new condition combination 1 Follow the steps shown in the screenshot 2nd Click on the dropdown arrow beside Add condition 3rd Choose Conditional combination 1st Double click on Conditional Channels in Project Tree ...

Страница 60: ...ing AND or OR relations To negate a condition right click on the condition and select Negation Combine several up to 16 conditions 3 Click Next to go to the next page Choose the output setting of the result Constant TRUE FALSE Result is as a constant with the value TRUE or FALSE Blinking Result is a blinking if the condition is fulfilled Pulse Result is a short one time pulse if the condition is f...

Страница 61: ...on Output configuration Write DDU 7 measurement variables to CAN messages output frequency and row counter are configurable CAN gateway functionality transfer from one bus to the other 9 1 CAN bus trivia CAN message 11 Bit standard or 29 Bit extended identifier Up to 8 bytes of data payload CAN bus Needs termination resistors 120 Ohm in wiring harness All devices connected to the bus must use iden...

Страница 62: ...e new CAN channel 1 Right click on CAN Input of desired bus CAN1 or CAN2 2 Select New CAN Channel from menu 3 Insert name and description of channel 4 Click OK when done Message Id Payload Area Row Counter Create new channel to read from CAN bus Export RaceCon CAN input configuration to file Import RaceCon CAN input configuration from file Display CAN bus properties Baudrate Import Vector CAN data...

Страница 63: ...d in the Data window and a CAN channel configuration window opens 9 2 3 CAN channel configuration Extraction of data from CAN bus Conversion to physical values Automatic assignment to measurement view Mini CAN analyzer functionality ...

Страница 64: ... the CAN channel b Enter CAN message ID Check the box if extended IDs 29 bit are used c If replacement values are used specify time out period and raw value d Check the box if a multiplexer row counter is used e Enter data position length and format f The bargraph shows assignment of the bytes Red colored fields show the assignment of the data bytes Orange colored fields show the assignment of the...

Страница 65: ...Enter CAN message ID Check the box if extended IDs 29 bit are used c If replacement values are used specify time out period and raw value d Check the box if a multiplexer row counter is used e Enter data position length and format f The matrix table shows the assignment of the bits Red colored fields show the assignment of the data bits Orange colored fields show the assignment of the multiplexer ...

Страница 66: ... 2 6 Special features CAN analyzer functionality This functionality is only available if a MSA Box I II is used to connect the DDU 7 to the PC Choose the CAN bus that is connected to the MSA Box to display the raw value and the converted physical value here Automatic creation of online measurement sheets The CAN channel can be automatically inserted to a measurement sheet Insert a name for a new s...

Страница 67: ...vehicle 1 Double click on Sheet 1 in Project Tree Measurement Sheet 1 is displayed in Main Area 2 Click on Measurement elements in the Toolbox 3 Drag the desired Measurement element e g Numeric Indicator and drop it on the Measurement Sheet Drag Drop ...

Страница 68: ...ilable channels 5 Drag desired Measurement channel and drop it on the Measurement element The measurement element displays the values of the assigned channel 6 Connect PC to the vehicle and switch to Race Mode by clicking F11 on the keyboard to display online data Drag Drop ...

Страница 69: ...le to import and click OK when done A channel import window opens 4 Select desired channels on the left and use the Add button to add them to import list 5 Click OK when complete The channels are inserted in the Data window 9 2 9 Export RaceCon CAN configuration 1 Right click on CAN Input of desired bus CAN1 or CAN2 2 Select Export from menu An Export Selection window opens ...

Страница 70: ... Import from menu A file browser opens 3 Select the input file and click OK An Import Selection window opens 4 Select channels to import 5 Drag and drop the channel to CAN Input of desired CAN bus on right hand side 6 Click Next If a measurement channel belongs to more than one source e g DDU 7 and ECU MS 5 1 the Solve Label Ambiguity window opens Drag Drop ...

Страница 71: ...ut of desired bus CAN1 or CAN2 2 Select New CAN Message from menu The Create new CAN message window opens 3 Enter name of message CAN Id and Grid output interval 4 Optionally specify a row counter multiplexer 5 Click OK when done Create new CAN output message Export RaceCon CAN output configuration to file Display CAN bus properties Baudrate Import RaceCon CAN output configuration from file ...

Страница 72: ...on DDU 7 in the DDU 7 Project Tree to display all labels 7 Select the desired measurement channel and drop it on message s bytes The measurement channel is assigned to the CAN message Output messages on CAN bus 1 Definition of CAN message Content of message Click here Drag Drop ...

Страница 73: ...ixed Byte Order can only be changed if a channel allocates more than one byte 9 3 4 Export RaceCon CAN configuration 1 Right click on CAN Output of desired bus CAN1 or CAN2 2 Select Export from menu The Export Selection window opens 3 Specify the filename 4 Click OK when done Set byte order of channel on CAN bus ...

Страница 74: ...input file and click OK An Import Selection window opens 4 Select channels to import 5 Drag and drop the channel to CAN Output of desired CAN bus on right hand side 6 Click Next If a measurement channel belongs to more than one source e g DDU 7 and ECU MS 5 1 the Solve Label Ambiguity window opens 7 Assign the ambiguous channels to the desired source 8 Click Finish ...

Страница 75: ... features 6 analog inputs 0 5 V 12 bit A D converter Switchable 3 01 kOhm pull up resistor 8 kHz acquisition rate up to 1 kHz recording rate Linear phase digital filter 4 frequency inputs 5 V Hall effect type 2 5 V trigger level 20 kHz max frequency 10 ms measurement window ...

Страница 76: ...er for the channel s name Measurement label Function raw_name mV value of sensor raw_name_fi filtered mV value of sensor name physical value of sensor name_fi filtered physical value Filtered channels are routed through digital low pass filters DDU 7 uses A D converter oversampling and digital filtering to recording rate Digital filters eliminate out of band noise Cut off frequency automatically a...

Страница 77: ...f I O Channels by clicking on in the DDU 7 Project Tree 3 Drag the Bosch Sensor Wizard from the Toolbox and drop it on the desired analog input channel in the DDU 7 Project Tree The Bosch Sensor Wizard opens 4 Click Finish when done 1st Choose the sensor s category 2nd Narrow your choice by choosing a type 3rd Select the exact type Opens sensor s datasheet These calibration values will be used ...

Страница 78: ...nserted into the DDU 7 Project Tree Available measurements for channel Measurement label Function raw_name mV value of sensor raw_name_fi filtered mV value of sensor name physical value of sensor name_fi filtered physical value Calculation of physical value with characteristic curve Input pin Pull up resistor is activated Channel is linked to ANA03 ...

Страница 79: ... DDU 7 Project Tree 3 Drag the Sensitivity Offset analog signal source from the Toolbox and drop it on the desired analog input channel in the DDU 7 Project Tree A Sensitivity Offset Wizard opens 4 To activate the internal DDU 7 pullup resistor check the box The internal DDU 7 pullup resistor is used to get a 5 V signal at the analog channel of the DDU 7 It allows you to use a push button The fixe...

Страница 80: ...easurement 7 Click Finish when done 8 Enter channel name and description 9 Click OK when done Choose unit group and unit of physical value Enter values from sensor datasheet Electrical pin value Physical channel value Physical limits of channel Enter physical limits of the sensor Choose data type of the measurement variable Check box to enable online calibration of offset and enter desired physica...

Страница 81: ...nts for channel Measurement label Function raw_name mV value of sensor raw_name_fi filtered mV value of sensor name physical value of sensor name_fi filtered physical value Input pin Pull up resistor is deactivated Sensitivity and Offset value for sensor Adjustment is enabled Channel is linked to ANA04 ...

Страница 82: ...near sensor Example Thermistor 5 kOhm From sensor data sheet resistance values over temperature The sensor has a nonlinear behavior Use characteristic curve for linearization Input voltage is the ratio between pull up resistor and thermistor 3 kOhm Pin Thermistor 5V ...

Страница 83: ...heck the box The internal DDU 7 pullup resistor is used to get a 5V signal at the analog channel of the DDU 7 It allows you to use a push button The fixed value of the internal DDU 7 pullup resistor is 3010 Ohm If using an additional external pullup resistor set up the overall resistance 5 Click Next when done The second part of the Sensitivity Offset Wizard opens Select physical unit Physical cha...

Страница 84: ...e DDU 7 Project Tree Available measurements for channel Measurement label Function raw_name mV value of sensor raw_name_fi filtered mV value of sensor name physical value of sensor name_fi filtered physical value Enter physical limits of the channel Choose data type of the measurement variable This sensor does not need offset calibration Input pin Pull up resistor is activated Characteristic curve...

Страница 85: ...y clicking on in the DDU 7 Project Tree 3 Drag the Multipoint Adjustment analog signal source from the Toolbox and drop it on the desired analog input channel in the DDU 7 Project Tree A Multipoint Adjustment Wizard opens 4 To activate the internal DDU 7 pullup resistor check the box The internal DDU 7 pullup resistor is used to get a 5 V signal at the analog channel of the DDU 7 It allows you to ...

Страница 86: ...p an online measurement 7 Click Finish when done 8 Enter channel name and description 9 Click OK when done Enter physical limits of the sensor Choose data type of the measurement variable Enable additonal online calibration Choose unit group and unit of physical value Enter physical adjustment values values here Can still be edited later Electrical pin value Select type of curve Physical limits of...

Страница 87: ...alue of sensor raw_name_fi filtered mV value of sensor name physical value of sensor name_fi filtered physical value Online definition of the curve is covered in the chapter 11 3 Online calibration of measurement channels of this manual Input pin Pull up resistor is deactivated Characteristic curve for sensor Adjustment is enabled Channel is linked to ANA06 ...

Страница 88: ...tails DDU 7 uses A D converter oversampling and digital filtering to recording rate Digital filters eliminate out of band noise Cut off frequency automatically adjusted to recording rate Example 100 Hz recording rate 10 ms 40 Hz passband 99 50 Hz stopband 1 ...

Страница 89: ...t of wheel speed Pulse wheel attached to wheel Each passing tooth of pulse wheel triggers hall sensor Calculation of wheel speed with wheel circumference 1 Click on Measurement Sources in the Toolbox 2 Expand the list of I O Channels by clicking on in the DDU 7 Project Tree 3 Drag the Velocity digital signal source from the Toolbox and drop it on the desired REV input channel in the DDU 7 Project ...

Страница 90: ...sensor name physical value of sensor name_fi filtered physical value Note Measurement of Revolution is similar Choose data type of the measurement variable Circumference of wheel for speed calculation Enter name to automatically create a new measurement sheet Input pin has hall interface Number of teeth Wheel circumference Channel is linked to REV01 Special functionality for sensors with frequency...

Страница 91: ...annel Computed vehicle speed Lap trigger covered in a special section Example Sensitivity offset calculation on input channel 1 Click Measurement Sources in the Toolbox 2 Drag the Sensitivity Offset computed source from the Toolbox and drop it on Computed Channels in the DDU 7 Project Tree A Computed Sensitivity Offset Wizard opens 3 Click Next when done Choose unit group and unit of output Enter ...

Страница 92: ... Click Finish when done 5 Enter channel name and description 6 Click OK when done The channel is inserted into the DDU 7 Project Tree Enter physical limits of the channel Choose data type of the measurement variable Check the box to force the channel s quantization if the quantization should be a fixed value in the whole CAN system Enter name to automatically create a new measurement sheet Physica...

Страница 93: ...the DDU 7 Project Tree A Hysteresis Wizard opens a Choose input measurement channel b Choose unit group and unit of output c Enter output value of state A in the unit selected in b d Enter threshold value when state changes from A to B e Enter delay time when state changes from A to B f Enter output value of state B in the unit selected in b g Enter threshold value when state changes from B to A h...

Страница 94: ...e The channel is inserted into the DDU 7 Project Tree Calculation of hysteresis channel Check the box to force the channel s quantization if the quantization should be a fixed value in the whole CAN system Choose data type of the measurement variable Enter name to automatically create a new measurement sheet Available measurements for channel Channels available in Computed Sources ...

Страница 95: ...put Calculated speed is average of both speeds if speed difference between wheels limit Calculated speed is maximum of both speeds if speed difference between wheels limit Calculating vehicle speed of 4 wheel drive Wheel speeds of all wheels as input Calculated speed is speed of 2nd fastest wheel 10 5 2 Setting up calculated speed for DDU 7 1 Click on tab System Overview 2 Click on Measurement Sou...

Страница 96: ...nserted into the DDU 7 Project Tree Choose driven axle Choose input source internal external Choose individual wheel speed channels Set limit for speed difference for calculation Configu ration window Measurement channels calculated speed and calculated distance Choose device Speed calculation in DDU 7 Project Tree ...

Страница 97: ... online measurement and calibration Communication interface Ethernet Communication protocol XCP 11 1 Achieving an online connection 11 1 1 Set up the PC for access to the DDU 7 1 Switch off local firewall on the PC 2 Set IP Configuration for the Ethernet interface to automatic configuration DHCP See chapter 7 1 1 Setting up the network interface for details 3 Start RaceCon 4 Establish the Ethernet...

Страница 98: ...t view and the DDU 7 Project Tree indicate a successful download and system consistency If the system s configuration in RaceCon has been changed the dot and background becomes yellow and a configuration download is necessary 11 1 3 Configuration download 1 Right click on DDU 7 in the DDU 7 Project Tree 2 Select Download configuration The configuration download starts ...

Страница 99: ...es and diagnostic variables Expand Measurement Container and Measurement Folder 1 in the Project Tree and double click on Sheet1 Sheet 1 is opened in the Main Area From the context menu of the project new measurement pages can be created From the context menu of a measurement page the folder can be renamed and deleted It also allows the creation of measurement pages ...

Страница 100: ...med and deleted To change between different pages click on the tabs on the bottom of the Main Project Area To add an element to a measurement sheet do following steps 1 Drag a measurement element from the Toolbox and drop it on the measurement sheet Drag Drop Tabs to switch between sheets ...

Страница 101: ... Tree to display all measurement channels 3 Select the desired measurement channel and drop it on the measurement element If the DDU 7 is online the value is displayed The measurement element s appearance can be changed using the Properties Menu Drag Drop ...

Страница 102: ...easurement 102 RaceCon offers different types of measurement elements Vertical Bar graph style Numeric indicator Temperature gauge Horizontal Bar graph style Measurement label Circular gauge Oscilloscope Chart ...

Страница 103: ...as with all other devices connected to RaceCon 1 During the configuration of a measurement channel select a measurement sheet from the list box or enter a name for a new measurement sheet 2 To create the sheets right click on DDU 7 and select Create measurement views from the DDU 7 context menu Select existing sheet from list or enter name of new sheet Click to create measurement sheets ...

Страница 104: ...n RaceCon is online press the F11 key to switch from Design Mode into Race Mode The measurement sheet is extended to full screen The button for offset calibration is active 2 Switch between different sheets using the tabs at the bottom of the page or the keyboard shortcuts associated with the sheets 3 Press the Esc key to return to Design Mode Raw and physical channel values Characteristic values ...

Страница 105: ...n is necessary Solution online offset calibration Example acceleration sensor 11 3 1 Enable online offset calibration for measurement channel During creation of the measurement channel In the channel view Activate switch to enable online calibration Check box to enable online offset calibration and enter desired physical target value ...

Страница 106: ...ysical target value e g 1 G and press the Calibrate button The sensor s offset is now calibrated 11 4 Group adjustment Group adjustment is the simultaneous online calibration of several channels This is useful e g to set all wheel forces and damper positions to 0 when the vehicle is positioned on a flat patch 11 4 1 Configuration of group adjustment Group adjustment consists of two components An i...

Страница 107: ...opens Note If a low active signal is selected as an input channel do not forget to enable the pull up resistor for the pin Otherwise the group adjustment will be triggered periodically See chapter 10 3 2 Configuring a generic linear sensor for further information concerning the pullup resistor Check the box to activate the internal DDU 7 pullup resistor and set the resistor value Select the pin to...

Страница 108: ... measurement sheets is explained in chapter 11 2 Setting up an online measurement 3 Click Finish when done 4 Enter channel name and description 5 Click OK when done Define minimum time between two activations Define minimum active time to detect activation Signal is active high or active low Enter name to automatically create a new measurement sheet ...

Страница 109: ...button 2 Make sure the pullup resistor is enabled if you selected active low trigger polarity 3 Double click on the input channel grp_adj_channel of the group adjustment 4 Download the configuration on the DDU 7 To connect the DD8 to RaceCon see chapter 7 1 4 Connecting the DDU 7 to RaceCon 5 Open a measurement sheet by clicking on the desired measurement sheet in the Project Tree 6 Drag the grp_a...

Страница 110: ...ple measurement of wheel force Physical property wheel force not directly measureable Load transfer through suspension kinematics Physical value at sensor position defined by vehicle Curve definition by online adjustment at vehicle Voltage at input pin State of adjustment 0 Idle 1 Adjustment triggered 2 Adjustment lock time Force at wheel Force at sensor Drag channels on Measurement Sheet ...

Страница 111: ... measurement channel in the Data Area to open the online view 5 Click on Calibrate adjustment points to open calibration window 6 Apply the desired physical condition to the sensor e g by applying a force on the wheel 7 Enter the physical value in the value column of the desired calibration point e g 745 N 8 Press the Calibrate button of the desired calibration point 9 Repeat for all curve points ...

Страница 112: ...libration curve is displayed in the online view Adjustment points vs offset adjustment UIN Fwheel_FR Calibration of individual curve points UIN Fwheel_FR Overall offset adjustment of all curve points E g to compensate sensor drift ...

Страница 113: ...al sensor interfaces Up to two independent recordings Measurement rate 1 ms 1 s Two global start conditions thresholds Up to 16 measurement conditions fast slow switches Telemetry Support for long range online telemetry Individual programmable team code Fast block slow block mechanism Programmable data rate Burst telemetry Support for burst telemetry BT 60 Programmable IP configuration BT 60 diagn...

Страница 114: ...k on Recording in DDU 7 Project Tree The recording configuration is displayed in the Main Area 3 To add measurement channels to a recording click DDU 7 in the DDU 7 Project Tree In the Data Area the measurement channels are displayed Variables can be grouped Tabs to access conditions settings and statistics Double click to display configuration ...

Страница 115: ...are recorded at the value chosen in Rate If the condition is true measurement channels are recorded at the value chosen in True rate 6 Click OK when done Drag measurement channels into group Recording properties Recording rate if condition is true Recording rate 1 ms 1 s Click to display DDU 7 variables Activate these filters Condition to switch between fast slow rate List of channels selected Set...

Страница 116: ... transmission of channel information e g speed rpm Slow blocks Block 2 n are transferred every n th cycle and used for a low frequent transmission of channel information e g tire pressure oil temperature Transmission Scheme If the maximum bandwidth of a block is reached a warning will be displayed To fix this problem you can view the allocation of the channels and data rate in the Statistics tab o...

Страница 117: ...ecording channels can be grouped To add a new group select Add group in the context menu of the recording The groups can be renamed to Gearbox Aero Engine etc 12 2 3 Global DDU 7 settings To display the global DDU 7 settings select the Settings Tab c d e f g a b ...

Страница 118: ...osch Motorsport e Choose or create the condition to start recording f If selecting WinDarab V7 in b enter a password hint and a password optional g Setting for automatic fragmentation Do not change 12 2 4 Recording statistics The tab Statistics shows the channels allocation and their current data rate related to the transmission frequency of the DDU 7 and the whole transmission system The overview...

Страница 119: ...r Discarding received data because of wrong timestamps Check wiring of SYNC signal BLKOK All measurement blocks have been set up correctly Some measurement blocks have not been set up correctly STARTED A measurement has been set up A measurement is not set up Either no recording configuration has been found or logger software upgrade is not activated 12 2 6 Displaying online recording diagnosis st...

Страница 120: ...rement correctly initialized DDU 7 is recording data 255 Values less than 254 indicate an error state statectrl_ok can be linked to an alarm on the display See chapter 8 2 3 Alarm display element for details 12 3 Configuration of online telemetry 12 3 1 Long range telemetry system FM 40 440 MHz band 25 KHz bandwidth 10 W max RF output 19 2 kBit s data rate unidirectional RS232 interface Full onlin...

Страница 121: ... Antenna B261208888 FM 40 Transmitter B261208898 RS232 RS422 RS232 Antenna Cable 8m B261209493 Control Module B261208871 Pit Receiver Box1 for one car F01TA20451 01 Connecting Cable 50m B261209481 optional Pit Receiver Box2 for two cars F01TA20455 01 DDU 7 Rod Antenna 7dBi B261208867 ...

Страница 122: ...M 40 in Project Tree to display the Properties Menu Drag drop Project Key 1111 9999 Baudrate of DDU 7 must match baudrate of FM 40 Transmission pause 5 recommended for improved re synchronisation Path to configuration folder of WDServer on receiver PC usually WDServer DCP to store telemetry configuration file ...

Страница 123: ... configuration is displayed in the Main Area 3 Click Edit channel s The Edit Recording Channels window appears 4 Choose between Fast Slow block transmission See chapter 12 2 2 Adding a recording group for information about Fast Slow block None channel s are not transferred Slow channel s are transferred in the slow telemetry block Fast channel s are transferred in the fast telemetry block ...

Страница 124: ...evices e g ECU MS 3 Sport ECU MS 5 1 1 Double click on FM 40 in Project Tree An overview of all available telemetry channels is displayed 2 Click on the telemetry channel you want to assign a special functionality 3 Click Edit channel s An Edit Telemetry Channel window appears 4 Choose the channel type The table below shows the function of the available channel types Measurement channel Function L...

Страница 125: ...T 60 5 GHz ISM band 20 MHz bandwidth 0 4 W max RF output 802 11a OFDM system proprietary protocol max 12 MBit s data rate bidirectional Ethernet interface to DDU 7 C 60 C 55 Partial track coverage Approx 300 m reception range High speed burst transmission of recorded data Link quality at Hockenheim ...

Страница 126: ...Recording and telemetry 126 12 4 2 Hardware setup BT 60 F Set F02UV00038 Ethernet Connecting Cable B261209743 BR 60 F Set F02UV00047 DDU 7 ...

Страница 127: ... compatible with the address range of the pit PC the BT 60 and the BR 60 1 Drop BT 60 from Toolbox into system overview 2 Open a measurement sheet 3 Drag the channel BURST_DEVICE_IP to the measurement sheet 4 Switch to Race Mode 5 Enter the desired IP address Enter IP address Drag drop ...

Страница 128: ...function requires the installation of Software Upgrade 2 Enable the Software Upgrade for USB recording USB recording is enabled by Software Upgrade 2 To activate Software Upgrade 2 enter the license key as described in the chapter 7 2 Feature activation Data ready for transmission Signal quality of radio link 55 dBm good 70 dBm fair 95 dBm no link DDU 7 connected to BT60 Byte counter for data tran...

Страница 129: ... 1 Insert the USB device into the PC and wait until it has been installed by Windows 2 In RaceCon select Extras and choose Format USB stick 3 Press Format An USB device is recognized by Windows as a storage medium but it can only be initialized with RaceCon and read with WinDarab 12 5 1 Recording data on USB device 1 Plug an USB device to DDU 7 2 Prepare a recording configuration in RaceCon 3 Powe...

Страница 130: ... Select Data logger C50 C55 C60 DDU7 DDU8 and click OK when done The Read measurement data dialog opens 11 Click on Modify button and select the base folder 12 Choose Flashcard as data transmission method 13 Choose DDU7 10 10 0 207 in the Vehicle dropdown list 14 Activate Auto save 15 Click Save when done Choose DDU7 in dropdown list Click Import Export ...

Страница 131: ...lick on the Start button and choose Open measurement file 19 Select the measurement files from the storage folder 20 Click on Open 21 Click in New Desktop to open a new measurement data window 22 Drag the desired measurement channel from the Channel list and drop it into the measurement data window The measurement channel s graph is displayed Note For more detailed descriptions and instructions re...

Страница 132: ...n no data on the USB device is recorded Configure the measurement label usb_mediastate on a RaceCon measurement view or on a DDU 7 display page The value of usb_mediastate reflects the operating condition of the USB bus State Description 0 Wait Device not found The USB device is not found also waiting for re plug stick No USB device inserted USB device is defect No electrical connection or wiring ...

Страница 133: ...uel consumption min max values Calculation of lap distance dependent functions Control of data logging system System consists of Transmitter trackside unit Receiver in vehicle unit Types of systems GPS based low cost low precision IR based low cost high precision limited reliability RF microwave based high precision high reliability Lap Trigger Receiver Lap Trigger Transmitter ...

Страница 134: ... triggers 15 ms Sub trigger 40 ms low active Recommendation for Bosch triggers 30 ms 13 1 2 Software functionality Race track topology and transmitter location frequently cause false triggers Software functionality prevents acceptance of false triggers Under race conditions trigger signals are sometimes missed Software functionality introduces forced trigger 13 1 3 Prevention of false triggers Min...

Страница 135: ... Laptrigger Wizard window opens Note In this example the Rx is connected to the dedicated lap trigger pin of DDU 7 The channel speed is calculated from 4 wheel speeds 3 Click Finish to complete the operation Choose the signal channel for the trigger signal Choose the signal device for the trigger signal Choose the source for vehicle speed Enter the distance of the racetrack Drag Drop ...

Страница 136: ...details f Define settings for segmented timing sub trigger See chapter 13 4 Segment timing for details g Define settings for countdown timer See chapter 13 5 Countdown timer for details h Change signal for vehicle speed if desired i Enter minimum speed for trigger release j Define settings for distance based retrigger protection See chapter 13 3 2 Distance based retrigger protection for details k ...

Страница 137: ...nel can be displayed Double click on any Laptrigger_xxx channel in the Data Area Example laptrigger_lapdist_dls A diagnosis window opens in Main Area Lap trigger diagnosis scheme Button to reset lap distance to 0 Button to reset lap counter Button to reset outing counter Button to generate trigger signal Button to reset best lap time Button to reset best lap time and distance based segmentation ...

Страница 138: ...rigger presettings When the reset buttons on the diagnosis page are activated these values are used Minimum laptime that a new best laptime is accepted Preset value for best laptime Preset values for lap counter and outing counter ...

Страница 139: ...p completed new lap starts Power OFF recording of lap completed system shutdown The system is counting Outing one or several laps from leaving the garage to entering the garage Lap min 20 of lap distance travelled Leaving the pits to lap trigger Lap trigger to lap trigger Lap trigger to entering the pits Fragment less than 20 of lap distance travelled Testbench operation Engine warm up Power cycle...

Страница 140: ...ading zeros 13 3 Lap timing There are different possibilities to adjust the lap trigger to the timing situation The detection time defines the minimum time the input signal changes its state E g a low active signal needs to be below the threshold for min 15 ms to release the trigger Channels for display To display lap times use the following channels Channel Function Laptrigger_lapcurr_dls Current...

Страница 141: ...trigger 141 13 3 1 Time based retrigger protection Trigger is locked for 5 s after main trigger was received To deactivate time based retrigger protection set Retrigger lock time to 0 ms 5000ms Main Trigger ...

Страница 142: ...ger 142 13 3 2 Distance based retrigger protection Trigger is locked until 80 of track distance has been covered 3200 m To deactivate distance based retrigger protection set min distance to 0 800m Main Trigger ...

Страница 143: ... a missed main trigger a forced trigger is inserted if 120 of the track distance has been covered 4800 m In this case the channel Laptrigger_distlap_dls starts at 800 m To deactivate distance based forced trigger uncheck box 800m Missed Trigger Forced Trigger ...

Страница 144: ...r segments are compared to Last lap completed Fastest lap Channels for display To display segment times use the following channels Channel Function Laptrigger_lapdiff Time difference between finished lap and last lap Laptrigger_lapdiffb Time difference between finished lap and best lap Laptrigger_dlast Difference of lap segment time compared to last lap Laptrigger_dbest Difference of lap segment t...

Страница 145: ...ub trigger mode Using main trigger 20 ms pulse at Start Finish Line 3 sub triggers 40 ms pulse positioned at 1000 m 2000 m and 3000 m To deactivate sub trigger mode uncheck box Main Trigger Sub Trigger Sub Trigger Sub Trigger ...

Страница 146: ...d enter desired segment distances Segment time is automatically calculated at each segment Time difference to last lap and fastest lap is automatically calculated at each segment To deactivate distance mode set Mode to None Main Trigger 2000m 3000m 0 0s 0 1s 0 2s 0 2s 0 2s 0 1s 0 1s 0 1s 0 2s 1000m 0 3s 0 1s 0 1s ...

Страница 147: ... minimum time spent in the pits An additional lap trigger Tx is configured as a segment trigger positioned at pit entry The trigger signal starts a timer countdown The current value of the timer is stored in the variable Laptrigger_cntdown_dls which can be displayed ...

Страница 148: ...e PST program file of the DDU 7 Configuration the configuration of Input channels CAN I O display configuration recording telemetry configuration Calibration data Characteristic curves and offsets created by online calibration at the vehicle Recorded data Measurement data recorded during vehicle operation ...

Страница 149: ... if the DDU 7 is connected to RaceCon The configuration of Input channels CAN I O display recording telemetry will not be changed 1 In the DDU 7 Project Tree right click on DDU 7 and choose Synchronize then Update firmware Version match Version does not match Firmware version consistency check Firmware check successful Update firmware Change program archive in RaceCon DDU 7 RaceCon ...

Страница 150: ...te starts The DDU 7 displays the message Updating firmware Do not switch off the car s ignition or interrupt the power supply of the DDU 7 When the firmware update is complete the DDU 7 displays the message Updating firmware finished Do a powercycle 4 Switch the car s ignition off and on again to cycle the power of the DDU 7 ...

Страница 151: ...ization Serial Interface is characterized by Voltage levels RS232 is standard 12 V UART 0 V 5 V needs level shifter Baud rate 9600 is standard for GPS DDU 7 supports 1200 115200 baud GPS Rx interface baud rate must match DDU interface baud rate DDU 7 Baud rate can be set with the GPS_BAUDRATE characteristic Data format DDU 7 expects 8 data bits no parity bit 1 stop bit 8N1 15 2 Protocol DDU 7 expe...

Страница 152: ...true course gps_year Years since 1900 gps_mon Months since January 0 11 gps_day Day of the month 1 31 gps_hour Hours since midnight 0 23 gps_min Minutes after the hour 0 59 gps_sec Seconds after the minute 0 59 gps_hsec Hundredth part of second 0 99 gps_smask Mask specifying types of packages from which data has been obtained gps_sig GPS quality indicator 0 Invalid 1 Fix 2 Differential 3 Sensitive...

Страница 153: ...sor and the DDU match Is the GPS sensor set up for 8N1 transmission parameters Is the GPS sensor set up for NMEA messages Are the GGA VTG RMC messages activated With a correctly wired and powered GPS sensor the changing GPS time information gps_sec can be immediately observed GPS sensor start up Does the GPS sensor view the sky Did the GPS sensor complete its initial start up procedure This may ta...

Страница 154: ... 16 1 Setting up fuel consumption calculation and tank management for DDU 7 1 Select Measurement Sources in Toolbox 2 Drag Fuel element and drop it on the vehicle in System Overview Do not drop it on the DDU 7 A fuel consumption wizard opens Drag Drop b c d e f g a ...

Страница 155: ...r inc for momentary consumption e Enter factor to correct calculated consumption in DDU 7 vs real consumption of vehicle if required f Choose method to calculate remaining laps with fuel in tank if desired using fuel consumption of last lap completed using target lap consumption entered in the field Target lap consumption g Choose values to initiate a reset of fuel consumption if desired manually ...

Страница 156: ...t label Function Fuel_fuelcons_dls Running fuel consumption starting at 0 Fuel_fuelrem_dls Remaining fuel in tank starting at tank capacity Fuel_fuellap_dls Fuel consumption for current lap starting at 0 Fuel_fuellapold_dls Fuel consumption of last lap completed Fuel_laprem_dls Remaining laps with fuel in tank Button to reset fuel consumption manually Can also be triggered by signal source or on p...

Страница 157: ...TRL F9 Start recording F10 or Alt Go to menu bar F11 Toggle display to fullscreen Race Mode F12 Enlarge main screen CTRL Tab Switch between opened windows Project Tree Plus at numeric pad or right cursor Expand selected node Minus at numeric pad or left cursor Close selected node Star at numeric pad Open all nodes DEL Delete seleted object Display page measurement page Cursor Move selected display...

Страница 158: ...d States of America Phone 1 248 876 2977 Fax 1 248 876 7373 Asia Pacific Bosch Engineering K K Motorsport 18th Floor Queen s Tower C 2 3 5 Minatomirai Nishi ku Yokohama 220 6218 Kanagawa Japan Tel 81 45 650 5610 Fax 81 45 650 5611 E Mail motorsport bosch com www bosch motorsport com Status 11 September 2012 All rights reserved by Bosch Engineering GmbH also for the case of patent reports All right...

Отзывы: