5. If the slope of the roof is less than 60º, the cap must extend at least 60 cm over the highest

point. If the slope is more than 60º and the cap cannot extend over the highest point, the tube

of the flue must extend at least 150 cm from the perforation.

6. When installations are performed in locations that are windy and/or when the flue extends

over 1.5 m from the roof, wire stays must be used to hold the flue in place.

7. A ceramic or stone floor protection must be placed under the stove when it is installed on a

wood or  plastic floor.

8.  If any type of handiwork, modifications or repairs have been executed close to the flue or

the stove after these have been installed, check that none of the specifications indicated in the
user’s manual have been altered.

9. If you smell burning or perceive overheating near your stove, request a  technical inspection

from an Authorized Technical Service.

10. Check that none of the components of the electrical system of your house are affected by

the stove or the flue.

3. As the inside of the flue must be

cleaned frequently, it should be

positioned as direct and vertical as

possible. Using elbows is not

recommended, but if necessary, no

more than two 135º elbows can be

used.To ensure proper draft, the

longitude of the flue must be between

4 and 10 meters.

4.- The double flue must preferably

be of galvanized steel or zinc alum

and 0.5 mm in thickness. Visible

interior flues can be painted with high

temperature paints (752º F/ 400ºC).

Exterior flues can be painted with

opaque enamel.

60 cms

150 cms

2. Once the stove is positioned, locate the center of the flue on the ceiling and make a perforation

that is 38 cm in diameter and goes through the roof to the exterior. A double flue must be

placed in the roof space section to ensure it is not in direct contact with flammable materials.

The space between the flue and the double flue must be filled with rock wool. Flammable

materials must not be closer than 15 cm from the double flue.

 - 3 -

OWNER'S MANUAL

IMPORTANT

The cap, funnel and the upper end of the flue are screwed

to each other. The funnel is not screwed to the double flue

to allow space for thermal dilation. This juncture 

MUST NOT

be screwed together.

IMPORTANT

The flues change tone as a result of the temperature generated

by the stove and may turn a red-blue color depending on the

type of stainless steel used. You can remedy this situation by

painting them with Bosca High Temperature Spray.

Main Flue

Cap

Screwed Juncture

Funnel
Free Juncture for

Dilatation

Rock wool

Double Flue

135º

135º

Содержание Aresta 360

Страница 1: ...0 Limit 380 Limit 450 Aresta 360 Aresta 400 Firepoint 360 Firepoint 400 Gold 400 Gold 800 Classic 400 Classic 450 Spirit 500 Spirit 550 Please read this entire manual carefully before installing and lighting your stove Save these instructions for future use Always follow the instructions contained in the manual F R E E S T A N D I N G N ...

Страница 2: ...dry firewood before buying it How do I check that the firewood is dry before using it How do I light the stove How do I reload firewood in the stove How do I turn off the stove MANTENANCE AND CLEANING What maintenance does my Bosca stove require How do I clean the flues on my stove How do I remove the ash from my stove How do I clean the glass panel on my stove CHIMNEY FIRE What is a chimney fire ...

Страница 3: ...hrough the firebox base Easy Lighting System Air Intake Refractive Bricks Removable Baffle Combustion Control Primary Air Control IMPORTANT THE INSTALLATION AND MAINTENANCE OF THIS STOVE IS COMPLEX AND MUST ONLY BE EXECUTED BY PROFESSIONALS CERTIFIED BY THE MANUFACTURER AUTHORIZED INSTALLERS ARE PROFESSIONALS WHO HAVE UNDERGONE DEMANDING TRAINING PROGRAMS 1 2 3 7 4 5 6 8 9 ...

Страница 4: ...it is the exhaust for the gases produced by the combustion of firewood These gases are extremely corrosive reach high temperatures and often contain fuel components Studies have demonstrated that fires related to stove or wood cookstoves usually originate near the flue We recommend you adhere strictly to the installation instructions detailed in this manual What is the most adequate location to in...

Страница 5: ...sary no more than two 135º elbows can be used To ensure proper draft the longitude of the flue must be between 4 and 10 meters 4 The double flue must preferably be of galvanized steel or zinc alum and 0 5 mm in thickness Visible interior flues can be painted with high temperature paints 752º F 400ºC Exterior flues can be painted with opaque enamel 60 cms 150 cms 2 Once the stove is positioned loca...

Страница 6: ...t This must be between 18 and 25 to ensure an adequate duration and avoid energy loss as a result of water evaporation as this reduces the power of the stove Additionally by using firewood with low humidity content you will avoid the production of creosote a residue of combustion that is deposited on the flues of your stove resulting in lower maintenance costs Remember to buy firewood that is no l...

Страница 7: ...ve 5 Open the door of the ashtray and keep it this way for approximately 3 minutes or until the splinters are lit 6 Open the upper door and add the load of firewood placing the lightest logs over the lit splinters It is very important that spaces are left between the logs as these allow for air circulation and consequently a faster and more vigorous ignition 7 Close the door and open the lower one...

Страница 8: ...a safe unit it is not necessary to turn it off However if you wish to do so all you have to do is adjust the Primary Air Control to minimum Remember that solid fuels react slowly so that this process will take several minutes IMPORTANT The minimum position on the Primary Air Control must only be used to turn off the stove It must never be used as a way to save firewood as the effect will be to mak...

Страница 9: ...rotect your hands by using safety gloves 2 Unscrew the cap and remove it IMPORTANT Bosca stoves contain a baffle that must be dismounted in order to clean the unit 3 Remove the anchoring screws to dismount the baffle of your stove We recommend you carefully read the instructions that correspond to your model and that are included with this manual 4 It is not necessary to totally remove the baffle ...

Страница 10: ...sited on the flue These are called creosote which is a fuel Under certain circumstances the interior of the flue catches fire producing extremely high temperatures that may reach such a level that the flue turns an incandescent red color Incandescent creosote emanations may appear on the upper extreme of the flue What should I do in the case of a chimney fire Stay calm A properly installed flue in...

Страница 11: ...y a serial number stamped on a plate on the back of the unit No other Bosca stove of similar model has the same serial number which may be requested if you require a service SAFETY PRECAUTIONS The stoves are designed to only use firewood as fuel The use of any other kind of fuel could damage the stove and make the warranty null and void Periodically inspect the flues and clean if n e c e s s a r y...

Страница 12: ...or of BOSCA Addresses No 8 Donkerhoek Pretoria 0002 South Africa Telephone 27 086 123 6342 Fax 27 012 802 1516 Postal Addess PO Box 15 Woodlands 0072 E Mail info bosca co za Web www bosca co za Made in Chile LIBRE POSICION ...

Отзывы: