Install & Operation Manual
Borg & Overström
GB
18
Maintenance & Cleaning
Sanitisation Guide
NOTE:
All maintenance operations must be carried out with the dispenser switched off. This
operation must only be carried out by trained staff. Every 6 months a sanitisation procedure is
recommended as follows:
Turn off incoming mains water.
Connect to filter head.
Add 25 ml of Bioguard Internal
Sanitisation fluid to a clean and
empty service filter cartridge.
Turn on incoming water, allow
service cartridge/doser to fill.
1
3
2
4
5
7
Dispense water using the cold
dispense lever until the water
appears pink. Briefly dispense
using the ambient lever too. Repeat
with sparkling dispense lever if
present.
Briefly dispense cold/ambient
water to release internal water
pressure from the machine.
Remove the existing filter.
Use Bioguard Hand Gel and put
on protective gloves.
8
Leave the solution inside machine
for sanitisation to take effect
(minimum 5 minutes) while
thoroughly cleaning the machine
externally
9
6
PINK
5
mins
Содержание S2