B4.2 Install & Operation Manual
Borg & Overström
AU
3
Controls
Factory set to:
Cold Thermostat
NB: Turn clockwise to decrease water temperature
-C
+C
Chilled
Chilled On/Off Switch: at upper rear of
machine, switches cooling operation on/off.*
Cold Thermostat: at rear of machine.
Chilled Button: Press to dispense cold water.
Chilled LED: Indicates chilling application is
switched on.
10A Fuse: On rear of machine, integral with
IEC socket.
*All Direct Chill variants incorporate an
auto-fill system
Ambient
Ambient Button: Press to dispense
ambient water.
Sparkling
Carbonation On/Off switch: Switches sparkling
operation on/off.
Sparkling Button: Press to dispense sparkling water.
Sparkling LED: Indicates sparkling application
is switched on.
Hot
Hot On/Off Switch: The hot water heating
mode is controlled by a switch on the back of
the unit, next to the cooling mode switch.
Hot Thermostat: regulated by a pre-set, non-
adjustable sensor on the tank.
Hot Button (incorporates safety lock): Press once
to unlock. Press again to dispense hot water.
(Note: Machine will revert to locked after 5
seconds if dispense is not activated.)
Hot LED: Indicates hot application is switched on.
Before installation
Allow adequate space to install the appliance.
Ensure the services are in place prior to installation.
Minimum
1340mm
Minimum
590mm
Minimum
590mm
Minimum
420mm
Minimum 420mm
Minimum 420mm
1/2” Shutoff
Valve
13 Amp
Socket
13 Amp
Socket
1/2” Shutoff
Valve